EXTECHINSTRUMENTS
MO300-en-GB_v1.4 7/16
9
DataMemoryStorage
StoringReadings:
1. Withthedatatobesavedinthedisplay,presstheSTOREbuttonfor2secondsuntiltheunit
beeps.Thedatawillbesavedtothememorylocationindicated.Thenumericdisplayabove
theMEMiconwillthenadvancetothenextlocation.
2. Whenthe20
memorylocationsarefull,theunitwilloverwriteoldsavedreadingsstarting
withmemorylocation01.
RecallingStoredReadings:
1. Simultaneouslypressandreleasethe▲and▼buttonstodisplaystoredreadings.The
numericdisplayabovetheMEMiconwillflashandthedatastoredinthatlocationwillbe
displayed.
2. Pressthe▲or▼buttontoscrollthroughthememorylocations.
3. Toreturntonormaloperatingmode,presstheSTOREbutton.
ClearingStoredData:
1. Toclearstoreddata,pressandholdthe▲andSTOREbuttonssimultaneouslyuntilCLR
appearsonthedisplay.
AutoPowerOff
Themeterwillenterasleepmodeafter30minutesofinactivity.Themeterwillemitawarning
beep15secondsbeforeshuttingdown.
TodisabletheAPOfeature,presstheMODEbuttonwhenturningthemeterON.The“APO”icon
willnotappear,indicatingitisdisabled.
Bluetooth
TM
andAndroid
TM
Communication
ThismeterincludesaBluetoothmoduledesignedtocommunicatewithanAndroidApplication
ExView™MO300.GetthisAppfromtheGooglePlaystore.
1. EnabletheMO300Bluetoothbypressingandholdingthe▲buttonfortwoseconds. The
Bluetoothiconwillappearinthedisplay.
2. PairthemetertotheAndroidtablet.Usepairingcode1234.
3. StarttheExView™MO300App.Tap“Connect”icon
topairthemeterwiththeApp.
4. Oncepaired,thedatafromtheMO300willbecontinuouslydisplayed andupdatedonthe
AndroidAppExView™MO300.
TypicalMoistureMeasurementandDocumentationProcedures
1. UsetheMoisturemetertomeasurethemoisturelevelsatvarioussuspectlocations.
2. Whenaspotofinterestislocated,storethemoisturereadinginthemoisturemeter’s
memory.
3. Recallthereadingfrommemory.Themoisturemeterwillnowcontinuouslytransmitthis
readingviaBluetooth.