AKM 380/IX/01

Whirlpool AKM 380/IX/01 Program Chart

  • Hello! I am an AI chatbot trained to assist you with the Whirlpool AKM 380/IX/01 Program Chart. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • How to ignite burner with safety device and electric ignition?
    What should be done when the burner fails to ignite?
    What happens if the burner's flame accidentally goes out?
    What is the minimum distance required between the separator panel beneath the cooktop and the cooktop?
    When using the double-ring burner, what should be done before selecting a lower setting?
    What should be the minimum height 'B' when the distance 'A' between wall cabinets is between 660 mm & 680 mm?
    What should be the minimum height 'B' when the distance 'A' between wall cabinets is greater than the cooktop's width?
    Where can I find the correct distance for installing a hood above the cooktop?
AKM 380/01 PRODUCT DESCRIPTION SHEET
IT
5019 319 60421
Operation of burners with safety
device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-clockwise
to the large flame and star setting .
At the same time, keep the knob pressed against
the control panel until the burner ignites.
After the burner has ignited, keep the knob
pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations
described above.
Note:
- Should particular local conditions of the delivered
gas make the ignition of the burner difficult, it is
advisable to repeat the operation with the knob
turned to the small flame setting .
- The safety device of the burner shuts off the gas
supply to the burner if its flame goes out
accidentally (because of a sudden gust of wind,
an interruption in the gas delivery, the
overflowing of liquids, etc).
- The separator panel, positioned beneath the
cooktop at a minimum distance of 20 mm, must
be sealed.
USING THE DOUBLE-RING BURNER
- When using the double-ring burner, leave the
knob on the maximum setting (large flame )
for at least five minutes after lighting before
selecting a lower setting.
1. Removable panstand grids
2-5. Medium burners
3. Large burners
4. Small burner
6. Double crown burner
7. Small burner control knob
8. Large burner control knob
9. Double crown burner control knob
10. Medium burner control knob
11. Medium burner control knob
Symbols
Shaded
circle
Tap closed
Large flame
and star
Maximum opening/delivery
and electric ignition
Small flame
Minimum opening or
reduced delivery
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTES: If the distance “A“ between the wall cabinets is between 660 mm and 680 mm, the
height “B” must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the
cooktop, the height “B” must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used Type of
burner
Injector
marking
Rated heat
capacity
Pcs-kW
Rated
consumption
Reduced
heat
capacity
Pcs-kW
Gas pressure
min. rat. max.
NATURAL GAS
(Methane) G 20
double crown
large
medium
small
139
128
94
76
3.30
3.00
1.65
1.00
314 l/h
286 l/h
157 l/h
95 l/h
1.50
0.60
0.35
0.30
17 20 25
LIQUID
PETROLEUM GAS
(Cylinder) G 30
double crown
large
medium
small
92
85
65
50
3.30
3.00
1.65
1.00
240 l/h
218 g/h
120 g/h
73 g/h
1.50
0.60
0.35
0.30
20 28-30 35
LIQUID
PETROLEUM GAS
(Cylinder) G 31
double crown
large
medium
small
92
85
65
50
3.30
3.00
1.65
1.00
236 g/h
214 g/h
118 g/h
71 g/h
1.50
0.60
0.35
0.30
25 37 45
Type of gas used Appliance model Total rated heat
capacity Pcs-kW
Total rated
consumption
Air required for
burning m
3
/h
G 20 20 mbar 5 gas 10.6 1009 l/h 21,2
G 30 28-30 mbar 5 gas 10.6 771 g/h 21,2
G 31 37 mbar 5 gas 10.6 757 g/h 21,2
/