AKS ACH 37 60 PL Instructions For Installation, Use And Maintenance

Category
Cooker hoods
Type
Instructions For Installation, Use And Maintenance
V.1.30.08.06
AKS Home Appliances
1
Instructions for installation, use and
maintenance
ACH 37 60 PL
V.1.30.08.06
AKS Home Appliances
2
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
FOR COOKER HOODS FOR WALL FITTING 230 Vac - 50 Hz
The equipment is constructed in accordance with European Standards and the requirements
included in the following Directives: 72/23 EEC (electric-low tension safety), 89/336 EEC
(electromagnetic compatibility), 93/68 EEC ( EC marking regulations).
Before installing and/or using the hood:
• read all the instructions thoroughly;
• make sure that the voltage (V) and frequency (Hz) rating indicated on the plate inside the
hood unit correspond to the mains supply available;
We recommend that the equipment be installed by expert personnel.
Installation
This hood can be used as an extractor or a
filtering unit. The unit must be fitted at a distance
of at least 65cm (75cm upon gas hobs) for the
cooking hob. It must not be mounted above
cookers fitted with top radiant plate. The
contaminated air mist be discharged in a manner
complying with current regulations.
Two different wall-mounting systems are used,
depending on the model (Fig. 1-2).
) Handling and leveling brackets
) Retaining screws
C) Hood/flue securing screws (just where it’s
provided)
D) Flue/wall bracket and securing screws.
Extractor (fume exhausted externally). Cooking fumes are
conveyed away from the kitchen to the outdoor environment
by way of ducting. Connect said tube with suitable diameter
to the junction supplied (Fig. 3) The tube should have its
outlet outside the house.
This pipe must not under any circumstances be connected to
cooker, boiler or burner exhaust pipes, etc.
If the hood is operated in suction whilst stove, gas cooker,
fuel-fed boilers, etc are being used, ventilation from outdoors
must be provided.
The suction model is not fitted with a carbon filter.
Fig
. 1
Fig
. 2
Fig
.
3
V.1.30.08.06
AKS Home Appliances
3
Filter (internal air recycle) (Fig.4) In this instance, cooking fumes directed up through the
activated carbon filters are purified and returned as clean air to the kitchen. The air outlet
must be unobstructed, and freely open to the kitchen space (Fig. 4)
Check that the carbon filters are installed by removing the metal covers illustrated (Fig.5).
Electrical connections
This appliance must be connected to an earthed power supply.
Two types of electrical connection can be used:
1) Using a standard plug connected to the power cable and inserted in a mains socket which
must be accessible at all times (so that the plug can be disconnected when servicing is
carried out).
2) By means of a fixed mains connection, fitting a bipolar switch with contact openings of at
least 3mm. The ground connection (yellow-green wire) must not be interrupted.
Operation
The hood is equipped with a multispeed motor.
It is recommended that low speed be selected for normal kitchen conditions and higher
speeds only to combat a heavy build-up odours and vapours.
The controls include an ON/OFF switch for the built-in light, and a further switch for activating
and selecting the running speed of the motor.
An indicator light remains on as long as the motor is in operation.
Maintenance and reminders
Always disconnect the hood from the electrical power supply before commencing any
maintenance or cleaning operation.
Particular care must be given to the grease filters, which serve to trap grease particles
entrained in cooking vapours. The grease filters are metal and must be washed at least once
a month with warm water and detergent (dishwasher clean is sufficient).
Dry thoroughly before refitting.
ATTENTION: the grease collected in the filter can easily catch fire and it is therefore
extremely important to clean the metallic filter on a regular basis as per instructions.
Grease filters are removed as illustrated (Fig. 5)
The function of the activated carbon filters is to
prevent the spread of odours present in the
cooking fumes. Clean air is returned to the
kitchen. Activated carbon filters cannot be washed
or serviced, and must be replaced 2 or 3 times a
year according to the amount of use.
Spare filters are obtainable from dealers or direct
from the manufacturer.
. 6
Fig
. 4
Fig
. 5
V.1.30.08.06
AKS Home Appliances
4
Removal: detach the metal covers and rotate the carbon filters clockwise (Fig.6) until free of
the motor.
Re-fitment: position the new carbon filter and reverse the procedure.
The hood should be cleaned with a soft damp cloth using neutral liquid detergents. Do not
use solvents, petroleum products or abrasives.
Never cook flambé dishes under the hood.
Never leave the hob unattended when frying, as oil or fat can catch fire.
THE MANUFACTURER DOES NOT ACCEPT LIABILITY FOR ANY DAMAGE OR INJURY
CAUSED IF THE USER FAILS TO FOLLOW THE ABOVE INSTRUCTIONS REGARDING
INSTALLATION MAINTENANCE AND THE PROPER USE OF THE COOKER HOOD.
Technical features
Voltage (V) : 230
Frequency (Hz) : 50
Watt : 160
Speed Noise
Selected (dbA)
1
st
minimum 45,6
2nd medium 52,3
3
rd
maximum 56,5