Ayyeka WAVELET 4R Quick start guide

Type
Quick start guide

Ayyeka WAVELET 4R is a versatile and feature-rich device designed to meet the demands of various monitoring applications. Its capabilities include:

  • Sensor connectivity: The WAVELET 4R supports a wide range of sensors, allowing you to monitor various parameters such as temperature, humidity, pressure, and more.

  • Data transmission: The device utilizes cellular connectivity to transmit data to the Ayyeka cloud platform, ensuring reliable and secure data delivery.

  • Remote monitoring: Access your data remotely through the user-friendly Ayyeka user interface, enabling you to monitor your assets and respond to events from anywhere with an internet connection.

Ayyeka WAVELET 4R is a versatile and feature-rich device designed to meet the demands of various monitoring applications. Its capabilities include:

  • Sensor connectivity: The WAVELET 4R supports a wide range of sensors, allowing you to monitor various parameters such as temperature, humidity, pressure, and more.

  • Data transmission: The device utilizes cellular connectivity to transmit data to the Ayyeka cloud platform, ensuring reliable and secure data delivery.

  • Remote monitoring: Access your data remotely through the user-friendly Ayyeka user interface, enabling you to monitor your assets and respond to events from anywhere with an internet connection.

QUICK START
GUIDE
WAVELET 4R
April 2020
P/N 0100711 Rev 1
AYYEKA
AYYEKA WAVELET SCHEMATIC
External
(Bottom)
3
It is important that you read the Quick Start Guide
in a controlled environment prior to installation .
Set up, activate, and successfully te st the entire
sys tem (Wavelet 4R, sensors, and antenna
connecti on) indoors, in a cont rolled environment,
before going to the field for installation.
!
1
IMPORTANT
Contact AYYEKA SUPPORT for technical support:
support@ayyeka.com
+1 (310) 876-8040 (US)
+31 40 209-1001 (EMEA)
ALWAYS COORDINATE Basic Wavelet Kit installation with
the local authority before starting installation works, which
should be completed by trained and authorized personnel.
The WARRANTY oered by Ayyeka covers only Ayyeka
supplied hardware and software for the duration of the
warranty period as per the warranty terms and conditions.
AYYEKA IS NOT LIABLE for damage or injury as a result
of handling, installation, or maintenance of its supplied
systems.
DO NOT THROW AWAY the Basic Wavelet Kit, as it contains
a lithium battery. Please dispose of properly.
CELLULAR NETWORK SIGNAL is required for proper
communication.
OPERATING TEMPERATURE RANGE of -40°C to -80°C
(-40°F to -176°F).
2
AYYEKA WAVELET SCHEMATIC
External
(Bottom)
SCHEMATIC
BOTTOM
Cellular
Sensor Input Port
17.4 cm (6.9 in)
13.3 cm
(5.2 in)
7.3 cm
(2.8 in)
AYYEKA
AYYEKA WAVELET SCHEMATIC
External
(Bottom)
3
TURN HERE
DO NOT
TURN HERE
GETTING STARTED
GETTING STARTED
BASIC
WAVELET KIT
1
2
3
4
Wavelet Device &
Protector
M12 Field Attachable
Sensor Connector
(optional; Ordered
separately)
Wavelet Activator
1x
GETTING STARTED
1x1x
1x
1x
M8 Female Field Attachable
Power Connector
(optional; see page 16)
4
Other tools and/or materials may be required (not included):
Electric Screw DriverRotary Hammer
5 6
Zip Ties, Screws, and
Anchors
Cellular Antenna
(REQUIRED; ordered separately)
4x2x 4x
5
NOTE: Special Installation Locations
WEAK SIGNAL LOCATIONS:
If the Wavelet is installed in
an area with weak cellular
signal, activate the Wavelet
and place in the intended
installation location with
closed doors/access hatch
(see step 3).
Log in to
home.ayyeka.com to
ensure that cellular signal
has been recently updated
in the last few minutes.
UNDERGROUND/INDOOR
WAVELET INSTALLATIONS:
Make sure the cellular
antenna is properly
installed to provide
adaquate signal quality
Wait for at least 15 minutes,
then log in to the user
interface at
home.ayyeka.com to make
sure stable communication
is conrmed
6
7
TURN HERE
DO NOT
TURN HERE
7
TURN HERE
DO NOT
TURN HERE
Connect the sensor cable assembly with the eld attachable
connector to the mating panel connector on the Wavelet.
Turn the adjustable stainless steel end piece to secure the
eld attachable connector to the Wavelet.
1
CAUTION: Do not turn the black plastic hood of the
connector. Turning the black hood may cause the wires to
disconnect, break, and/or damage the connector pins.
SENSOR CONNECTION
7
EXTERNAL ANTENNA CONNECTION
Connect the cellular antenna to the antenna port (ANT 1).
2
WAVELET ACTIVATION
Place the magnetic Wavelet Activator on the embossed
Ayyeka logo on the front of the Wavelet enclosure. Wavelet
will initiate a 15 minute test mode of high frequency
sampling and transmission. The device will then return to its
default conguration.
3
IMPORTANT NOTE:
The antenna does not appear in the remaining depictions
in this guide, but should remain connected once properly
secured to the appropriate panel connectors.
Cellular Antenna
8
WAVELET ACTIVATION
Verify the installation with your mobile phone by using
AyyekaGo mobile application.
If you haven’t already done so, download the AyyekaGo
mobile app for iOS or for Android. Search the App Store or
Google Play for “AyyekaGo” or use the QR codes below
There are two ways to pair your phone with your Wavelet:
1. Select ”Get Key Via Web”. This will direct you to enter
your log-in credentials for the StreamView user interface.
2. Select ”Enter Key Manually. The Mobile Pair Key is found
in the StreamView user interface in the Devices tab.
4
Access the Ayyeka user interface at home.ayyeka.com using
your log-in credentials. Expect data to appear
between 5 10 minutes after the test mode is initiated.
5
9
WAVELET ACTIVATION
6
The screen display should resemble the following:
If the Wavelet is
transmitting properly,
you have completed the
installation successfully and
can begin collecting and
viewing your data!
If data does not transmit
properly, change the
Wavelet installation
location and activate again
(step 3). If the problem
persists, contact Ayyeka for
assistance.
support@ayyeka.com
+1 (310) 876-8040 (US)
+31 40 209-1001 (EMEA)
10
Attaching the protector
7 After the Wavelet completes the transmission process, place
the Wavelet protector above the connector ports and secure
the Wavelet protector into the Wavelet enclosure.
CAUTION: The protector is provided to shield the
connector from tampering or overexposure that could
result in disconnected wiring.
GETTING STARTED
a. Insert the two lower clips into the two lower holes of the
Wavelet enclosure.
b. Snap the upper clips into place in the two grooves above
the panel connector.
Lower Clips
Upper Clips
a
b
11
11
Secure the Wavelet on a wall, pipe, or other secure
mounting location using zip ties or screws.
8
OR
Wall
Mounted
Pipe
Mounted
12
YOUR WAVELET 4R IS NOW
SUCCESSFULLY INSTALLED!
13
WAVELET 4 ANALOG
ANALOG
PANEL CONNECTOR #1 M12 8-PIN MALE
Connector
Pin #
Function
Name
Pin Assignment
1
Signal+
4
-20mA or 0-24V Input #1 Front
2
Common
Negative (
-)
3
Supply+
Wavelet 12V Power Supply #2 (+)
4
Supply+
Wavelet 12V Power Supply #1 (+)
5
Signal+
4
-20mA or 0-24V Input #4
6
Signal+
4
-20mA or 0-24V Input #3
7
Signal+
4
-20mA or 0-24V Input #2
8
Common
Negative (
-)
+1 (310) 876-8040 (US)
+31 (40) 209-1001 (EMEA)
info@ayyeka.comwww.ayyeka.com
WAVELET PINOUT
PANEL CONNECTOR – M12 8-PIN MALE
Connector
Pin #
Function Description
Pin
Assignment
1 Signal 4-20mA or 0-24V Input #1
Front
2 Signal PCNT_0 – pulse counting, edge,
periodic, output
Dry contact, open drain, 0V or
2.8V (max)
3 Signal RS485 A and RS232 RX
4 Supply Wavelet 12V Power Supply #1 (+)
5 Signal RS485 B and RS232 TX Back
6 Signal 4-20mA or 0-24V Input #2
AYYEKA WAVELET SCHEMATIC
External
(Bottom)
#2
7 Signal PCNT_1 – pulse counting, edge,
periodic, output
Dry contact, open drain, 0V or
2.8V (max)
8 Common GND
14
GETTING STARTED
3 pos
4 pos
inner view
( 2 : 1 )











namedate






42K1A316
Strakerjahn
26.07.11
16.09.11 Hüther
Female connector M8x1, field
attachable , axial, screw termination
see table
Indndex: c 18.07.13 KH Ä4842
Wire cross section adapted












3
1
Ø14
(
R
E
F
. 4
0
)
Ø13,7
Width across
flats 13
Width across
flats 12
Max. external cable
diameter see table
Width across
flats 13
4
2
1
3
Materials:
Contact:
Contact plating:
Contact carrier:
Cable sealing:
O-Ring:
Coupling nut:
Housing:
CuZn
Au over Ni
in mating area
PA6, UL 94
NBR
Silicone / NBR
CuZn, Ni
PA6 GF, UL 94
Installation specification for locking nut
to counter connector:
Recommended
torque:
Conec
installation tool:
0,4 Nm
Torque wrench:
36-000200
Insert across flats 13:
36-000220
Description:
SAL - 8 - RKC3-S
Cable-
:
4 - 5,5mm
SAL - 8 - RKC4-S
4 - 5,5mm
Part no:
42-00010
42-00012
Pos:
3
4
termination
Ø1,9
Technical specification:
Rated voltage:
IEC 61076-2-104
Current rating:
IEC 61076-2-104
Insulation resistance:
IEC 60512
Pollution degree:
IEC 60664-1
Degree of protection:
IEC 60529
Temperature range:
IEC 60664-1
Mating cycles:
IEC 60512-9a
Wire cross section:
3pos 4pos
60 V 30 V
4 A at 40°C
with 0,5mm²
>= 100 M
3/2
IP 67, in mated
condition
-30°C ... +85°C
>= 100
AWG 20 / max. 0,5 mm²
SW 0,9
Installation tool for
wire termination
( included )
4
M8 3-Pin Female
Power Connector
Wire To Connect:
Cable Wire Cross
Section Surface Area
0.14 – 0.5 mm
2
Wire Gauge AWG 26-20
Cable Ø Diameter 4 – 5.5 mm
+ Installation Tool
for Wire Termination
(Included)
No
Connection
5-28VDC (+)
Negative (-)
POWER CONNECTOR PINOUT
If using an external power source, refer to the pinout below:
EXTERNAL POWER:
4
3
1
POWER – PANEL CONNECTOR #4 – M8 3-PIN MALE
Connector
Pin #
Function Description Pin
Assignment
1 Supply+ 5-28VDC (+)
Front
3 No Signal No Connection
4 Common Negative (-)
POWER
PANEL CONNECTOR #4 M8 3-PIN MALE
Connector
Pin #
Function
Name
Pin Assignment
1
Supply+
5
-28VDC (+) Front
3
No Signal
No Connection
4
Common
Negative (
-)
WAVELET 4 POWER
4
3 1
+1 (310) 876-8040 (US)
+31 (40) 209-1001 (EMEA)
info@ayyeka.comwww.ayyeka.com
15
NOTES
www.ayyeka.com
support@ayyeka.com
+1 (310) 876-8040 (US)
+31 40 209-1001 (EMEA)
QUESTIONS?
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Ayyeka WAVELET 4R Quick start guide

Type
Quick start guide

Ayyeka WAVELET 4R is a versatile and feature-rich device designed to meet the demands of various monitoring applications. Its capabilities include:

  • Sensor connectivity: The WAVELET 4R supports a wide range of sensors, allowing you to monitor various parameters such as temperature, humidity, pressure, and more.

  • Data transmission: The device utilizes cellular connectivity to transmit data to the Ayyeka cloud platform, ensuring reliable and secure data delivery.

  • Remote monitoring: Access your data remotely through the user-friendly Ayyeka user interface, enabling you to monitor your assets and respond to events from anywhere with an internet connection.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI