Reznor F Installation guide

Type
Installation guide

This manual is also suitable for

Reznor B is a versatile and powerful unit heater designed to provide efficient and reliable heating solutions for various industrial, commercial, and agricultural applications. With its advanced features and capabilities, it offers exceptional performance and ease of use.

  • Powerful Heating: Equipped with a robust heating element, Reznor B delivers exceptional heating capacity, ensuring quick and effective space warming.

  • Adjustable Heat Output: The heater provides adjustable heat output, allowing you to customize the temperature to suit your specific needs and preferences.

  • Efficient Fuel Utilization: Reznor B utilizes fuel efficiently, minimizing energy consumption and operating costs while delivering optimal heating performance.

Reznor B is a versatile and powerful unit heater designed to provide efficient and reliable heating solutions for various industrial, commercial, and agricultural applications. With its advanced features and capabilities, it offers exceptional performance and ease of use.

  • Powerful Heating: Equipped with a robust heating element, Reznor B delivers exceptional heating capacity, ensuring quick and effective space warming.

  • Adjustable Heat Output: The heater provides adjustable heat output, allowing you to customize the temperature to suit your specific needs and preferences.

  • Efficient Fuel Utilization: Reznor B utilizes fuel efficiently, minimizing energy consumption and operating costs while delivering optimal heating performance.

Form I-F/B250/300/400, PN 102860 (Rev 2), Page 1
WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance can
cause property damage, injury or death. Read
the installation, operation, and maintenance
instructions thoroughly before installing or
servicing this equipment.
HORIZONTAL/VERTICAL
VENT OUTLET
Installation Form RZ-NA I-F/B250/300/400-HV
Obsoletes Form 434-HV (Version 1)
Applies to: Model F 250, 300, and 400 and
Model B 250, 300, and 400
®
Model F and B 250, 300, and 400 unit heaters require field assembly of the vent outlet. Using the 26 , #10 x
1/2 sheetmetal screws (24 in the plastic bag and the two screws used to hold the flue outlet pieces in place
during shipping), carefully follow the illustrated instructions on page 2 to assemble the outlet vent.
DANGER: Failure to provide proper venting could result in death, serious injury,
and /or property damage. The unit must be installed with a vent connection and proper
vent to the outside of the building. Follow the instructions on page 2 and the venting
instructions in the installation manual.
SEE PAGE 2
! CAUTION:
THIS HEATER
REQUIRES ASSEMBLY
OF FLUE OUTLET.
REFER TO
INSTRUCTIONS ON
THIS SHEET.
! CAUTION:
THIS HEATER
REQUIRES ASSEMBLY
OF FLUE OUTLET.
REFER TO
INSTRUCTIONS ON
THIS SHEET.
Form I-F/B250/300/400, PN 102860 (Rev 2), Page 2
ASSEMBLY INSTRUCTIONS FOR VENT OUTLET -- Models F and B 250, 300, and 400
These instructions and illustrations show the vent outlet being assembled in the horizontal position. To assemble the
vent outlet in the vertical position, follow the instructions reversing the positions of the flue collar assembly (Step 3)
and the cover (Step 4).
2. Attach the Flue
Collar Support
Position the support around the hole in the drafthood
with the opening toward the back of the heater.
Fasten with nine sheetmetal screws.
3. Attach the Flue Collar Assembly
Position the flue collar
assembly over the rear
opening.
Fasten with seven
sheetmetal screws.
Vertical Vent Installation Note: For vertical vent outlet,
reverse the positions of the flue collar assembly (Step 3)
and the cover (Step 4).
4. Attach the Cover
Position the flat cover
over the top opening.
Attach with ten
sheetmetal screws.
5. Installation of the vent outlet is complete. When the
outlet is in the horizontal position, it is recommended
that a 12"-18" piece of straight pipe be connected to
the flue pipe before installing an elbow.
Follow the instructions in the installation manual for
venting the heater.
(800) 695-1901, www.RezSpec.com
©2014 Reznor, LLC. All rights reserved. Printed in the U.S.A.
Trademark Note: Reznor
®
is registered in the United States and other countries.
0514 OG POD Form I-F/B250/300/400-HV (Version 0.1)
1. Remove the two center screws (one on each side) that are
holding the three flue outlet pieces in place during shipping. Use
these screws and the screws (#10x1/2" sheetmetal screws) in the
plastic bag.
The three pieces are: 250, 300 400
Flue Collar Support 102857 102857
Cover 102855 102855
Flue Collar Assembly 102846 102847
Flue Collar
Support
Drafthood
Sheetmetal
Screws (9)
Flue
Collar
Support
Flue Collar
Assembly
Sheetmetal
Screws (7)
Flue Collar
Assembly
Cover
Sheetmetal
Screws (10)
Cover
  • Page 1 1
  • Page 2 2

Reznor F Installation guide

Type
Installation guide
This manual is also suitable for

Reznor B is a versatile and powerful unit heater designed to provide efficient and reliable heating solutions for various industrial, commercial, and agricultural applications. With its advanced features and capabilities, it offers exceptional performance and ease of use.

  • Powerful Heating: Equipped with a robust heating element, Reznor B delivers exceptional heating capacity, ensuring quick and effective space warming.

  • Adjustable Heat Output: The heater provides adjustable heat output, allowing you to customize the temperature to suit your specific needs and preferences.

  • Efficient Fuel Utilization: Reznor B utilizes fuel efficiently, minimizing energy consumption and operating costs while delivering optimal heating performance.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI