  • Hello! I am an AI chatbot trained to assist you with the Generation Lighting 44662 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Installation And Safety Instructions
Line art shown may not exactly match the fixture enclosed. However, the installation instructions do apply to
this fixture. Fill in Item Number on Carton and File This Sheet For Future Reference. ITEM#_______________
HC-1431
FIGURE 1
*NOT INCLUDED
0
81908
Car
efully remove the fixture from the carton and check that all parts
are included, as shown in figure 1. Be careful not to misplace
any of the screws or parts which are needed to install this fixture.
Be sure the electricity to the system you are working on is turned
off; either the fuse removed or the circuit breaker set at off.
Use of other manufacturers components will void warranty, listing
and create a potential safety hazard.
If you are unclear as to how to proceed, contact a qualified electrician.
You don’t need special tools to install this fixture.
Be sure to follow the steps in the order given.
Read instructions carefully.
Save these instructions.
IMPORTANT SAFETY INSTRUCTIONS
BEFORE YOU BEGIN
T
o clean, wipe fixture with a soft cloth. Clean glass with a mild soap.
Do not use abrasive materials such as scouring pads or powders,
steel wool or abrasive paper.
K
eep this sheet for future reference, and in case you need to order
replacement parts. Parts for this fixture can be ordered from place of
purchase. Be sure to use exact wording from illustration when
ordering parts.
CLEANING
ORDERING PARTS
Place back plate (D) against wall and mark location for drywall
anchors. Remove back plate (D) and drill appropriate sized holes into
drywall for anchors.
Pull supply wires through appropriate opening in backplate (D). Place
backplate (D) against wall and secure by installing dry wall screws
into anchors. Install outlet box screws (not supplied) into outlet box
through appropriate openings in backplate (D) if applicable.
IMPORTANT: DO NOT ATTACH FIXTURE DIRECTLY TO OUTLET BOX.
STEP 1:
STEP 2:
INSTALLATION
BACKPLATE
(D)
MOUNTING
SCREWS (F)
GREEN
GROUNDING
SCREW (G)
FIXTURE
GROUND
WIRE
*DRYWALL
ANCHOR
STEP 1
STEP 2
*SUPPLY
GROUND
WIRE
*WIRE
CONNECTOR
OPENING FOR
DRYWALL
SCREWS*
STEP 2
STEP 5
STEP 4
GROUNDING INSTRUCTIONS: The green grounding screw (G) is to
be inserted into the hole with two raised dimples provided on the
backplate (D). Wrap the ground wire from the fixture (if supplied) and
t
he ground wire from the outlet box (bare metal or green insulated
wire) around the green grounding screw (G) on the backplate (D) if
uninsulated wire is on the backplate (D), connect the ground wire
from the fixture (if supplied) and the outlet box to it using a small wire
connector (not supplied).
NEVER CONNECT GROUND WIRE TO BLACK OR WHITE POWER
SUPPLY WIRES.
INSTALLATION (continued) HC-1431
STEP 3:
STEP 4:
M
ake sure no bare wires can be seen outside wire connectors. After
wires are connected, tuck them carefully inside outlet box. Push the
canopy (I) firmly over the mounting screws (F) and against the wall.
Secure canopy (I) in place by threading cap nuts (E) onto fixture
mounting screws (F).
Install lamps (not supplied).
P
lace shade (A) on socket cup (B) and secure by threading retaining
ring (H) onto socket.
FINAL ASSEMBLY
STEP 5:
STEP 6:
STEP 7:
*NOT INCLUDED
CANOPY (I)
BACKPLATE
(D)
SOCKET
CUP (B)
SHADE (A)
RETAINING
RING (H)
MOUNTING
SCREWS (F)
GREEN
GROUNDING
SCREW (G)
FIXTURE
GROUND
WIRE
CAP NUTS (E)
*SUPPLY
GROUND
WIRE
*WIRE
CONNECTOR
A
.
U
se a listed wire connector to connect the fixture hot wire (black
wire, or round and smooth tracer) to the supply hot wire.
B. Use a listed wire connector to connect the fixture common wire
(white wire, or square and rigid) to the supply common wire.
C
.
G
ently try to remove the wires from the connector. If you can
remove the wires, carefully re-do the wiring connection.