Manual 0-5277 1 INTRODUCTION
Cigweld Pty Ltd
71 Gower Street
Preston, Victoria, Australia, 3072
Telephone: +61 3 9474 7400 • FAX: +61 3 9474 7488
Website: www.cigweld.com.au
Manual No 0-5277_AB
Addendum page for
Transmig 350i, 450i, 550i
Packaged Items
Transmig 350i Plant (Part No: W1005350)
Transmig 350i Inverter Power Source
Transmig 4RT wirefeeder, 10pin
8m interconnection lead, 10pin
Tweco Professional No.4 Mig Torch Euro, 3.6m
Comet Professional Argon regulator/owmeter
Feed roll: 0.9/1.2mm V groove (tted)
Electrode holder with 5m lead
Work clamp with 5m lead
Heavy Duty Trolley with inbuilt cylinder carrier
Operating manual
Transmig 350i Power Source (Part No: W1005352)
Transmig 350i Inverter Power Source
Operating manual
Transmig 450i, Standard Plant (Part No: W1005450)
Transmig 450i Inverter Power Source
Transmig 4RT wirefeeder, 10pin
8m interconnection lead, 10pin
Tweco Professional No.4 Mig Torch Euro, 3.6m
Comet Professional Argon regulator/owmeter
Feed roll: 0.9/1.2mm V groove (tted)
Electrode holder with 8m lead
Work clamp with 8m lead
Heavy Duty Trolley with inbuilt cylinder carrier
Operating manual
Transmig 450i, Pro Plant (Part No: W1005451)
Transmig 450i Inverter Power Source
Transmig VAF4 Wirefeeder with Euro Connection
8m Interconnection Lead, 19 pin
Spool Cover Kit
Tweco Professional Supra XT Mig Torch, 4m, Euro
connection
Comet Professional Argon regulator/owmeter
Feed roll: 0.9/1.2mm V groove (tted)
Electrode holder with 8m lead
Work clamp with 8m lead
Heavy Duty Trolley with inbuilt cylinder carrier
Operating manual
Transmig 450i Power Source (Part No: W1005452)
Transmig 450i Inverter Power Source
Operating manual
Transmig 550i Plant (Part No: W1005550)
Transmig 550i Inverter Power Source
VA4000 wirefeeder, 19pin
15m interconnection lead, 19pin
Tweco Professional Supra XT Mig Torch, 4m, Tweco
connection
Comet Professional Argon regulator/owmeter
Feed roll: 1.3/1.6mm V groove (tted)
Electrode holder with 8m lead
Work clamp with 8m lead
Heavy Duty Trolley with inbuilt cylinder carrier
Operating manual
Transmig 550i Power Source (Part No: W1005552)
Transmig 550i Inverter Power Source
Operating manual
TRANSMIG 350i, 450i,550i Addendum
INSTALLATION/SETUP 2 Manual 0-5277
Wire Feeder Set Up for Mig Welding
WARNING
Before connecting the work clamp to the work make sure the mains power supply is switched off.
CAUTION
Loose welding terminal connections can cause overheating and result in the male plug being fused in
the terminal. Remove any packaging material prior to use. Do not block the air vents at the front or
rear of the Welding Power Source.
NOTE
Depending on the type of wire you will be using the MIG Torch polarity may need to be switched. Follow
the wire manufacturers recommendation.
Connection to Transmig 350i,450i,550i for MIG (GMAW) Welding with Gas Shielded Mig Wire
When using a Gas Shielded wire with the 4RT or VAF4 Wire Feeder, you need to have an external gas source at-
tached to the 4RT or VAF4 Wire Feeder.
For most Gas Shielded wire, connect the Work Lead to the negative - terminal on the front of the Transmig Power
Source and connect the Welding Power Cable from the back of the 4RT or VAF4 to the positive + terminal on the
front of the Transmig Power Source. Check with wire manufacturer for recommended polarity. Welding current
ows from the Power Source via heavy duty bayonet type terminals. It is essential, however, that the male plug is
inserted and turned securely to achieve a sound electrical connection.
The 4RT or VAF4 Wire Feeder requires an interconnection cable assembly to connect from the back of the 4RT or
VAF4 to the front of the Transmig welding power source. 2, 8 and 15M lengths are available. The 4RT uses a 10
pin interconnection cable assembly and the VAF4 Wire Feeder uses a 19 pin interconnection cable.
Connect the MIG Torch to the front of the 4RT or VAF4. See Figure 1 and Figure 2.
Front View 4RT
Rear View 4RT
Control Cable
Welding Power Cable
from Wire Feeder
Work Lead
Gas Hose
+
_
Art# A-11279
Transmig 350i,450i,550i
10 Pin
Control
Socket
Figure 1: Setup for 4RT Wirefeeder with Gas Shielded MIG Wire
Addendum TRANSMIG 350i, 450i, 550i
Manual 0-5277 3 INTRODUCTION
Mig Torch
VAF4 Wirefeeder
Work Lead
19 Pin Control Socket
Negative Welding Terminal (-)
Positive Welding
Terminal (+)
Art # A-11260
Figure 2: Setup for VAF4 Wirefeeder with Gas Shielded MIG Wire
TRANSMIG 350i, 450i,550i Addendum
INSTALLATION/SETUP 4 Manual 0-5277
Connection to Transmig 350i,450i,550i for MIG (FCAW) Welding with Gasless MIG Wire
When using a gasless ux cored wire, you do not need to have an external gas source attached to the 4RT or VAF4
Wire Feeder. If one is, then make sure it is turned off.
For most Self Shielded Flux Cored Wire, connect the Work Lead to the positive + terminal on the front of the Power
Source and connect the Welding Power Cable from the back of the 4RT or VAF4 to the negative - terminal on the
front of the Power Source. Check with wire manufacturer for recommended polarity. Welding current ows from
the Power Source via heavy duty bayonet type terminals. It is essential, however, that the male plug is inserted
and turned securely to achieve a sound electrical connection.
The 4RT or VAF4 Wire Feeder requires an interconnection cable assembly to connect from the back of the 4RT or
VAF4 to the front of the Transmig welding power source. 2, 8 and 15M lengths are available. The 4RT uses a 10
pin interconnection cable assembly and the VAF4 Wire Feeder uses a 19 pin interconnection cable.
Connect the MIG Torch to the front of the 4RT or VAF4. See Figure 3 and gure 4.
Front View 4RT
Rear View 4RT
Control Cable
Welding Power Cable
from Wire Feeder
Work Lead
+
_
Art# A-11280
Transmig 350i,450i,550i
10 Pin
Control Socket
Figure 3: Setup for 4RT Wirefeeder with Gasless MIG Wire
Addendum TRANSMIG 350i, 450i, 550i
Manual 0-5277 5 INTRODUCTION
Art # A-11537
Positive Welding
Terminal (+)
Work Lead
VAF4 Wirefeeder
19 Pin Control Socket
Mig Torch
Figure 4: Setup for VAF4 Wirefeeder with Gasless MIG Wire
TRANSMIG 350i, 450i,550i Addendum
INSTALLATION/SETUP 6 Manual 0-5277
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

ESAB Transmig 350i, 450i, 550i Troubleshooting instruction

Type
Troubleshooting instruction
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI