Filename: XPA200-7984-I-OPT1_Errata_a.doc 2
4. Section 5.8.3.5 should be amended to include (amendments or
changes in bold):
. . .
+10_2_xx’cr’ +10 PS#2 Fault
SHTD_xx’cr’ Thermal Shutdown
. . .
Note: A temperature fault is indicated if the unit is less than -
20C or more than 85 degrees C. This creates a summary fault and
will cause the unit to mute itself and switchover to the back-up
unit. However, the 10V supply to the FET transistors will remain
on until the unit reaches the thermal shutdown temperature of 90
degrees C or above. For protection reasons, the unit will
shutdown the 10V supply to the power transistors at temperatures
at or above 90 degrees C.
5. Section 5.8.3.8 should be amended to include (amendments or
changes in bold):
. . .
Confirmation: >DEV/PACRCS_aabcde'cr''lf']
where: aa = # of 0.25 dB steps in HEX above 0dB (0to120)
b = 1 if Amplifier ON, 0 if OFF
c = 1 if Tx ON, 0 if OFF, 2 if external mute
command, 3 if external inhibit command
d = 1 if unit ONLINE, 0 if OFFLINE
e = 1 if Auto Recovery enabled, else 0
6. Section 5.8.3.9 should be amended to include (amendments or
changes in bold):
. . .
iii = RF forward pwr, .1 dBm steps above 26.0 dBm in Hex
jjj = RF reverse pwr, .1 dBm steps above 19.0 dBm in Hex
7. Section 5.8.3.12 should be amended to include (amendments or
changes in bold):
. . .
Confirmation: >DEV/PACRAS_abcdefghijkl'cr''lf']
. . .
. . .
g = 1 if +10 PS#2 Fault, else 0
h = 1 if TEMP Fault, else 0
i = 1 if Thermal Shutdown, else 0
j = 1 if FAN 1 Fault, else 0
k = 1 if FAN 2 Fault, else 0
l = 1 if PROC Fault, else 0