SEFRAM 5472DC User manual

Category
Measuring, testing & control
Type
User manual

This manual is also suitable for

Digital Storage Oscilloscope
SEFRAM 5472DC / 54102DC / 54152DC
USER MANUAL
M54X2DC A 00
SEFRAM 5472DC/54102DC/54152DC TABLE OF CONTENTS
SEFRAM 5472DC/54102DC/54152DC TABLE OF CONTENTS
4
Table of Contents
SAFETY INSTRUCTIONS ........................... 11
Safety Symbols ............................................................................... 11
Safety Guidelines ........................................................................... 12
Power cord for the United Kingdom .................................. 16
GETTING STARTED .................................... 17
Main Features ......................................................................... 17
Panel Overview ....................................................................... 19
Front Panel ....................................................................................... 19
Rear Panel ......................................................................................... 24
Display ................................................................................................ 25
Setting up the Oscilloscope ............................................... 27
QUICK REFERENCE .................................... 30
Menu Tree and Shortcuts .................................................... 30
CH1/CH2 key ................................................................................... 31
Cursor key 1/2 ................................................................................ 33
Cursor key 2/2 ................................................................................ 33
Display key ....................................................................................... 35
Autoset key ...................................................................................... 35
Hardcopy key .................................................................................. 36
Help key ............................................................................................. 36
Horizontal menu key ................................................................... 36
Math key 1/2 (+/-/x) ................................................................... 38
SEFRAM 5472DC/54102DC/54152DC TABLE OF CONTENTS
5
Math key 2/2 (FFT/FFT rms) .................................................... 39
Measure key .................................................................................... 40
Run/Stop key .................................................................................. 40
Save/Recall key 1/10 ................................................................... 41
Save/Recall key 2/10 ................................................................... 41
Save/Recall key 3/10 ................................................................... 42
Save/Recall key 4/10 ................................................................... 42
Save/Recall key 5/10 ................................................................... 44
Save/Recall key 6/10 ................................................................... 44
Save/Recall key 7/10 ................................................................... 45
Save/Recall key 8/10 ................................................................... 45
Save/Recall key 9/10 ................................................................... 47
Save/Recall key 10/10 ................................................................ 47
Trigger key 1/6 .............................................................................. 49
Trigger key 2/6 .............................................................................. 49
Trigger key 3/6 .............................................................................. 51
Trigger key 4/6 .............................................................................. 51
Trigger key 5/6 .............................................................................. 53
Trigger key 6/6 .............................................................................. 53
Utility key 1/11 (Utility #1) ....................................................... 54
Utility 2/11 (Utility #2)................................................................ 54
Utility key 3/11 (Utility #3) ....................................................... 55
Utility key 4/11 (Hardcopy -Save All) ................................. 55
Utility key 5/11 (Hardcopy -Printer) .................................... 56
Utility key 6/11 (Hardcopy -Save Image) ......................... 56
Utility key 7/11 (Probe compensation) .............................. 57
Utility key 8/11 (Go-NoGo) ...................................................... 57
Utility key 9/11 (Data Logging 1/2)..................................... 58
Utility key 10/11 (Data Logging 2/2) .................................. 58
Utility key 11/11 (Self CAL Menu) ........................................ 59
Default Settings ..................................................................... 60
SEFRAM 5472DC/54102DC/54152DC User Manual
6
Built-in Help ............................................................................ 61
MEASUREMENT ........................................ 63
Basic Measurements ............................................................. 63
Activating a channel .................................................................... 63
Using Autoset ................................................................................. 64
Running and stopping the trigger ....................................... 66
Changing the horizontal position and scale ................... 67
Changing the vertical position and scale ......................... 68
Using the probe compensation signal ............................... 70
Automatic Measurements .................................................... 72
Measurement items ..................................................................... 72
Automatic measurement gating ............................................ 74
Automatically measuring the input signals...................... 76
Cursor Measurements........................................................... 79
Using the horizontal cursors ................................................... 79
Using the vertical cursors ......................................................... 80
Math Operations .................................................................... 81
Overview ............................................................................................ 82
Adding, subtracting or multiplying signals ...................... 83
Using the FFT function ............................................................... 84
Go No-Go Testing.................................................................. 86
Overview ............................................................................................ 86
Edit: NoGo When .......................................................................... 88
Edit: Source ...................................................................................... 88
Edit: NoGo Violation Conditions ........................................... 90
Edit: Template (boundary) ........................................................ 90
Run Go-NoGo Tests..................................................................... 95
Data Logging .......................................................................... 96
SEFRAM 5472DC/54102DC/54152DC TABLE OF CONTENTS
7
Overview ........................................................................................... 96
Edit: Source ...................................................................................... 97
Edit: Setup Parameters ............................................................... 97
Run Data logging ......................................................................... 99
CONFIGURATION .................................... 100
Acquisition ............................................................................. 100
Selecting the acquisition mode ........................................... 100
Selecting Delay mode .............................................................. 102
Real time vs Equivalent time sampling mode .............. 104
Display .................................................................................... 105
Selecting vector or dot drawing ......................................... 105
Accumulating the waveform ................................................. 105
Adjusting the display contrast ............................................. 106
Selecting the display grid ....................................................... 106
Horizontal View .................................................................... 108
Moving the waveform position horizontally ................. 108
Selecting the horizontal scale .............................................. 108
Selecting the waveform update mode ............................ 109
Zooming the waveform horizontally ................................. 111
Viewing waveforms in the X-Y mode ............................... 113
Horizontal Adjustment Menu ............................................... 115
Vertical View (Channel) ...................................................... 117
Moving the waveform position vertically ....................... 117
Selecting the vertical scale ..................................................... 117
Selecting the coupling mode ............................................... 117
Expand Vertical Scale Center / Ground ........................... 118
Inverting the waveform vertically ....................................... 119
Limiting the waveform bandwidth ..................................... 121
Probe attenuation level and type ....................................... 121
SEFRAM 5472DC/54102DC/54152DC User Manual
8
Trigger ..................................................................................... 123
Trigger type .................................................................................. 123
Trigger parameter ...................................................................... 123
Configuring Holdoff .................................................................. 126
Configuring the edge trigger ............................................... 126
Configuring the video trigger .............................................. 128
Configuring the pulse width trigger ................................. 129
Manually triggering the signal ............................................ 131
Rear Panel USB Port Interface ......................................... 132
Remote Control Interface .................................................. 133
System Settings .................................................................... 135
Viewing the system information ........................................ 135
Selecting the language ........................................................... 135
SAVE/RECALL .......................................... 137
File Structures ....................................................................... 137
Display image file format ....................................................... 137
Waveform file format ............................................................... 137
Setup file format ........................................................................ 140
Using the USB file utilities ..................................................... 141
Quick Save (HardCopy) ...................................................... 143
Save ......................................................................................... 145
File type/source/destination ................................................. 145
Saving the panel settings ...................................................... 146
Saving the waveform ............................................................... 147
Saving the display image ....................................................... 150
Saving all (panel settings, display image, waveform)
............................................................................................................ 152
Recall ....................................................................................... 154
SEFRAM 5472DC/54102DC/54152DC TABLE OF CONTENTS
9
File type/source/destination .................................................. 154
Recalling the default panel settings .................................. 155
Recalling a reference waveform to the display ........... 157
Recalling panel settings........................................................... 157
Recalling a waveform ............................................................... 158
Recall Image .................................................................................. 160
PRINT ....................................................... 162
Print (Hardcopy) ................................................................... 162
MAINTENANCE ....................................... 166
Vertical Resolution Calibration ........................................ 166
Probe Compensation .......................................................... 167
FAQ .......................................................... 169
The input signal does not appear in the display. ...... 169
I want to remove some contents from the display. .. 169
The waveform does not update (frozen). ....................... 171
The probe waveform is distorted. ...................................... 171
Autoset does not catch the signal well. .......................... 171
I want to clean up the cluttered panel settings.......... 171
The saved display image is too dark on the
background. ................................................................................... 171
The accuracy does not match the specifications........ 173
The oscilloscope will not allow a 2M waveform to be
saved. ................................................................................................ 173
APPENDIX ................................................ 174
Fuse Replacement ................................................................ 174
SEFRAM 5472DC/54102DC/54152DC User Manual
10
Specifications ........................................................................ 176
Model-specific specifications ............................................... 176
Common specifications ........................................................... 178
Probe Specifications ........................................................... 182
Probe for 5472DC ...................................................................... 182
Probe for 54102DC ................................................................... 183
Probe for 54152DC ................................................................... 184
Dimensions ............................................................................ 185
EC Declaration of Conformity .......................................... 186
SEFRAM 5472DC/54102DC/54152DC
11
SAFETY INSTRUCTIONS
This chapter contains important safety instructions
that should be followed when operating and
storing the oscilloscope. Read the following before
any operation to ensure your safety and to keep
the oscilloscope in the best condition.
Safety Symbols
These safety symbols may appear in this manual or on the
oscilloscope.
WARNING
Warning: Identifies conditions or practices that
could result in injury or loss of life.
CAUTION
Caution: Identifies conditions or practices that
could result in damage to the oscilloscope or to
other objects or property.
DANGER High Voltage
Attention: Refer to the Manual
Protective Conductor Terminal
Earth (Ground) Terminal
SEFRAM 5472DC/54102DC/54152DC User Manual
12
Safety Guidelines
General
Guideline
CAUTION
SEFRAM 5472DC/54102DC/54152DC
13
(Measurement categories) EN 61010-1:2001 specifies the
measurement categories and their requirements as follows.
The SEFRAM 53X2DC series falls under category II.
Measurement category IV is for measurement performed
at the source of a low-voltage installation.
Measurement category III is for measurement performed
in a building installation.
Measurement category II is for measurement performed
on circuits directly connected to a low voltage installation.
Measurement category I is for measurements performed
on circuits not directly connected to Mains.
Power Supply
WARNING
AC Input voltage: 100 ~ 240V AC, 47 ~ 63Hz
The power supply voltage should not fluctuate
more than 10%.
Connect the protective grounding conductor of
the AC power cord to an earth ground.
Fuse
WARNING
Fuse type: T1A/250V
To ensure fire protection, replace the fuse only
with the specified type and rating.
Disconnect the power cord before replacing the
fuse.
Make sure the cause of fuse blowout is fixed
before replacing the fuse.
Cleaning the
oscilloscope
Disconnect the power cord before cleaning the
oscilloscope.
Use a soft cloth dampened in a solution of mild
detergent and water. Do not spray any liquid
into the oscilloscope.
Do not use chemicals containing harsh products
such as benzene, toluene, xylene, and acetone.
SEFRAM 5472DC/54102DC/54152DC User Manual
14
Operation
Environment
Storage
environment
SEFRAM 5472DC/54102DC/54152DC
15
Disposal
Do not dispose this instrument as unsorted
municipal waste. Please use a separate collection
facility or contact the supplier from which this
instrument was purchased. Please make sure
discarded electrical waste is properly recycled to
reduce environmental impact.
SEFRAM 5472DC/54102DC/54152DC User Manual
16
Power cord for the United Kingdom
When using the oscilloscope in the United Kingdom, make sure the
power cord meets the following safety instructions.
NOTE: This lead/appliance must only be wired by competent persons
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in this lead are coloured in accordance with
the following code:
Green/ Yellow:
Earth
Blue:
Neutral
Brown:
Live (Phase)
As the colours of the wires in main leads may not correspond with the
coloured marking identified in your plug/appliance, proceed as follows:
The wire which is coloured Green & Yellow must be connected to the Earth
terminal marked with either the letter E, the earth symbol or coloured
Green/Green & Yellow.
The wire which is coloured Blue must be connected to the terminal which is
marked with the letter N or coloured Blue or Black.
The wire which is coloured Brown must be connected to the terminal
marked with the letter L or P or coloured Brown or Red.
If in doubt, consult the instructions provided with the equipment or contact
the supplier.
This cable/appliance should be protected by a suitably rated and approved
HBC mains fuse: refer to the rating information on the equipment and/or
user instructions for details. As a guide, a cable of 0.75mm2 should be
protected by a 3A or 5A fuse. Larger conductors would normally require
13A types, depending on the connection method used.
Any exposed wiring from a cable, plug or connection that is engaged in a
live socket is extremely hazardous. If a cable or plug is deemed hazardous,
turn off the mains power and remove the cable, any fuses and fuse
assemblies. All hazardous wiring must be immediately destroyed and
replaced in accordance to the above standard.
SEFRAM 5472DC/54102DC/54152DC
17
GETTING STARTED
The Getting started chapter introduces the
oscilloscope’s main features, appearance, and set
up procedure.
Main Features
Model name
Frequency bandwidth
Input channels
5472DC
DC 70MHz (3dB)
2
54102DC
DC 100MHz (3dB)
2
54152DC
DC 150MHz (3dB)
2
Performance
1 GS/s real-time sampling rate
25GS/s equivalent-time sampling rate
2M points record length
Up to 10ns peak detection
2mV~10V vertical scale
1ns ~ 50s time scale
Features
5.7 inch color TFT display
Saving and recalling setups and waveforms
27 automatic measurements
Multi-language menu (12 languages)
Math operation: Addition, Subtraction,
SEFRAM 5472DC/54102DC/54152DC User Manual
18
Interface
SEFRAM 5472DC/54102DC/54152DC
19
Panel Overview
Front Panel
LCD
Display
Function
keys
VARIABLE
knob
Menu keys
Trigger
LEVEL knob
Trigger
keys
Ground
Terminal
CH1
terminal
USB port CH2
terminal
Probe
compensation
output
EXT TRIG
terminal
Power
switch
Horizontal
POSITION
knob
Horizontal
MENU key
TIME/ DIV
knob
CH1/ CH2/
MATH keys
Vertical
POSITION
knob
VOLTS/ DIV
knob
VOLTS/DIV VOLTS/DIV TIME/DIV
CH 1 MATH CH 2 MENU MENU
Acquire Display Utility Help
Run/Stop
VARIABLE
FORCE
Autoset
Cursor
SINGLE
Hardcopy
Measure Save/Recall
LEVEL
VERTICAL HORIZONTAL TRIGGER
CH1
CAT300V
MW15pF
MAX. 300Vpk
1
CH2 EXT TRIG
CAT300V
MW15pF
MAX. 300Vpk
1
X Y
150 MHz 1 G Sa/s
Digital Storage Oscilloscope
GDS-1152A-U
LCD display
TFT color, 320 x 234 resolution, wide angle view
LCD display.
Function keys:
F1 (top) to
F5 (bottom)
Activates the functions which
appear in the left side of the LCD
display.
Variable knob
VARIABLE
Increases or decreases values and
moves to the next or previous
parameter.
Acquire key
Acquire
Configures the acquisition mode
(page 100).
Display key
Display
Configures the display settings
(page 105).
SEFRAM 5472DC/54102DC/54152DC User Manual
20
Cursor key
Cursor
Runs cursor measurements (page
79).
(Continued on next page)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188

SEFRAM 5472DC User manual

Category
Measuring, testing & control
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI