Primare DIRIS A60 Operating instructions

Type
Operating instructions

This manual is also suitable for

DIRIS A60
Operating instructions
F GB
D I
NL E P
2
DIRIS A60 - Ref.: 536 418 A GB
DANGER AND WARNING _______________________ 3
PRELIMINARY OPERATIONS ____________________ 4
PRESENTATION ________________________________ 5
INSTALLATION _________________________________ 6
PROGRAMMING ______________________________ 12
OPERATION __________________________________ 43
CONNECTION TEST FUNCTION ________________ 48
ASSISTANCE _________________________________ 52
TECHNICAL CHARACTERISTICS ________________ 53
GLOSSARY OF ABBREVIATIONS _______________ 56
Contents
3
DIRIS A60 - Ref.: 536 418 A GB
This equipment must be mounted only by professio-
nals.
The manufacturer shall not be held responsible for
failure to comply with the instructions in this manual.
Risk of electrocution,
burns or explosion
the device must be installed and serviced only by
qualified personnel
prior to any work on or in the device, isolate the
voltage inputs and auxiliary power supplies and
short-circuit the secondary winding of all current
transfromers (PTI SOCOMEC)
always use an appropriate voltage detection device
to confirm the absence of voltage
put all mechanisms, door and covers back in place
before energising the device
always supply the device with the correct rated vol-
tage
Failure to take these precautions could cause serious
injuries.
Risk of damaging device
Chek the following :
the voltage of the auxiliary power
the frequency of the distribution system (50 or
60 Hz)
the maximum voltage across the voltage-input ter-
minals, (V1, V2, V3 and VN) 500 V AC phase-to-
phase or 289 V AC phase-to-neutral
a maximum current of 6 A on the current-input ter-
minals (I1, I2 and I3)
DANGER AND WARNING
4
DIRIS A60 - Ref.: 536 418 A GB
DANGER AND WARNING
For personnel and product safety please read the
contents of these operating instructions carefully
before connecting.
Check the following points as soon as you receive
the package:
• the packing is in good condition,
the product has not been damaged during transit,
the product reference number conforms to your
order,
the packaging included a product fitted with deta-
chable terminal strips,
• operating instructions.
5
DIRIS A60 - Ref.: 536 418 A GB
PRÉSENTATION
1. Key-pad with 6 dual-function keys (display or pro-
gramming)
2. Backlit LCD display
3. Phase
4. Values
5. Unit
6. Activity indicator on the communication bus
7. Energy metering indication
8. Hour meter and energy display
9. Alarm relay 1
10. Alarm relay 2
6
DIRIS A60 - Ref.: 536 418 A GB
INSTALLATION
avoid being close to systems generating elec-
tromagnetic disturbances,
avoid vibrations involving accelerations greater
than 1 G for frequencies lesser than 100 Hz.
RECOMMENDATIONS
CUT-OUT DIAGRAM, MOUNTIG
3.62
+0.03
in
92
+0,8
mm
0
0
3.62
+0.03
in
92
+0,8
mm
0
0
Max. 0.31 in
Max. 8
mm
ni 87.3
mm 69
3.82 in
97 mm
ni
4
5
.
3
mm 09
0.94 in
24 mm
ni 02.2
mm 65
ni 51.3
mm 08
ni 28.0
mm 12
3.54 in
90 mm
7
DIRIS A60 - Ref.: 536 418 A GB
CONNECTION
Each CT’s secondary winding must be
short-circuited when disconnecting the
DIRIS. This can be done automatically using
one of Socomec’s catalogue products: the
PTI. Please contact us for further informa-
tion.
DIRIS A60
Å Aux.: IEC / CE 110 … 400 V AC
120 … 350 V DC
12 … 48 V DC
Ç Fus.: 0.5 A gG / BS 88 2A gG / 0.5 A class CC
DIRIS A60
INSTALLATION
S2 S1 S2 S1 S2S1
I2 I3I1
V1 V2 V3 VN
1
2
81
71
+
-
Input Synchro
10...30 V DC
0.24 in / 6 mm
Flat 3,5
0,5 mm² - 2,5 mm²
0.27 in / 7 mm
Flat 5,5
Pozidriv 1
0,5 mm² - 6 mm²
7lb-in / 0.8Nm
3.5lb-in / 0.4Nm
8
DIRIS A60 - Ref.: 536 418 A GB
INSTALLATION
MODULES OPTION
DIRIS A60 can be fitted with optional modules:
- JBUS/MODBUS communication;
ref: 4825 0092:
RS485 JBUS/MODBUS serial port in RTU
mode with a speed from 2400 to 38400 baud.
(Operating instructions ref: 536 103).
- PROFIBUS-DP Communication;
ref: 4825 0205:
RS485 PROFIBUS-DP serial port with a speed
from 9,600 baud to 12 Mbaud.
(Operating instructions ref: 535 749).
- Pulse outputs; ref: 4825 0090:
2 pulse outputs connected to the metering of
energy in kWh, kvarh and KVAh.
(Operating instructions ref: 536 045).
- Analogue outputs; ref: 4825 0093:
2 analogue outputs 4/20 mA or 0/20 mA confi-
gurable for measures performed by the DIRIS
A60. 2 modules can be installed, a maximum
of 4 outputs.
(Operating instructions ref: 536 048).
- Inputs/Outputs; ref: 4825 0094:
2 outputs allocated for alarms, for voltage, cur-
rent, power, power factor and THD, or remote
control.
2 inputs for the metering of pulses or control-
ling position.
(Operating instructions ref: 536 047).
- Ethernet; réf : 4825 0203 :
Link with RJ45 connector.
Protocol MODBUS/TCP or JBUS/
MODBUS RTU with TCP. WEB-ser-
ver for configuration of the product, dis-
play of the main quantities and diagnosis.
(Operating instructions ref.: 535 748).
- Ethernet/gateway RS485; ref: 4825 0204:
Link with RJ 45 connector.
Master gateway function MODBUS with 3
points link RS485.
Protocol MODBUS/TCP or JBUS/MODBUS
RTU with TCP. WEB-server for the configura-
tion of the product, display of the main quan-
tities and diagnosis.
(Operating instructions ref.: 535 748).
- Temperature; ref: 4825 0206.
PT100 Technology:
4 temperature indicators :
- 1 internal
- 3 external (PT100 input)
(Operating instructions ref.: 535 750).
- Operating earth; ref.: 48250087
(Operating instructions ref.: 536 423).
DIRIS 343 A
9
DIRIS A60 - Ref.: 536 418 A GB
DIRIS 272 E
UNBALANCED THREE-PHASE NETWORK
(4NBL)
UNBALANCED THREE-PHASE NETWORK
(3NBL)
DIRIS A60
INSTALLATION
DIRIS 278 D
DIRIS 280 DDIRIS 276 C
Å Aux.: IEC / CE 110 … 400 V AC
120 … 350 V DC
12 … 48 V DC
Ç Fus.: 0.5 A gG / BS 88 2A gG / 0.5 A class CC
P1
S1
P1
S1
L1
(
R
)
L2
(
S
)
L3
(
T
)
P1
S1
S2 S1 S2 S1 S2S1
I2 I3I1
V1 V2 V3 VN AUX
2
1
2
L1
(
R
)
L2
(
S
)
L3
(
T
)
S2 S1 S2 S1 S2S1
I2 I3I1
V1 V2 V3 VN AUX
P1
S1
P1
S1
2
2
1
L1
(
R
)
L2
(
S
)
L3
(
T
)
S2 S1 S2 S1 S2S1
I2 I3I1
V1 V2 V3 VN AUX
P1
S1
P1
S1
2
1
2
Å Aux.: IEC / CE 110 … 400 V AC
120 … 350 V DC
12 … 48 V DC
Ç Fus.: 0.5 A gG / BS 88 2A gG / 0.5 A class CC
10
DIRIS A60 - Ref.: 536 418 A GB
DIRIS A60
INSTALLATION
BALANCED THREE-PHASE NETWORK (3BL/4BL)
The solution using one CT, with the 3rd phase
current calculated via vectoral summation, results
in an 0.5% reduction in phase accuracy.
P1
S1
L1
(
R
)
L2
(
S
)
L3
(
T
)
S2 S1 S2 S1 S2S1
I2 I3I1
V1 V2 V3 VN AUX
2
1
2
DIRIS 282 D
1
2
L1
(
R
)
L2
(
S
)
L3
(
T
)
S2 S1 S2 S1 S2S1
I2 I3I1
N
P1
S1
V1 V2 V3 VN AUX
2
DIRIS 679 B
Å Aux.: IEC / CE 110 … 400 V AC
120 … 350 V DC
12 … 48 V DC
Ç Fus.: 0.5 A gG / BS 88 2A gG / 0.5 A class CC
11
DIRIS A60 - Ref.: 536 418 A GB
DIRIS A60
INSTALLATION
TWO-PHASE NETWORK (2BL)
SINGLE-PHASE NETWORK (1BL)
DIRIS 284 D
N
P1
S1
L1
(
R
)
S2 S1 S2 S1 S2S1
I2 I3I1
V1 V2 V3 VN AUX
2
1
2
Å Aux.: IEC / CE 110 … 400 V AC
120 … 350 V DC
12 … 48 V DC
Ç Fus.: 0.5 A gG / BS 88 2A gG / 0.5 A class CC
Å Aux.: IEC / CE 110 … 400 V AC
120 … 350 V DC
12 … 48 V DC
Ç Fus.: 0.5 A gG / BS 88 2A gG / 0.5 A class CC
AAA
aaa
L1 (R)
L2 (S)
L3 (T)
V1 V2 V3
1
2
DIRIS 680 B
VOLTAGE TRANSFORMER
P1
S1
L1
(
R
)
L2
(
S
)
S2 S1 S2 S1 S2S1
I2 I3I1
V1 V2 V3 VN AUX
2
1
2
DIRIS 285 D
Å Aux.: IEC / CE 110 … 400 V AC
120 … 350 V DC
12 … 48 V DC
Ç Fus.: 0.5 A gG / BS 88 2A gG / 0.5 A class CC
12
DIRIS A60 - Ref.: 536 418 A GB
DIRIS A60
PROGRAMMING
ACCES TO PROGRAMMING MODE (COdE 100)
x 1
x 1
x 1
confirm
x 1
3 sec
13
DIRIS A60 - Ref.: 536 418 A GB
DIRIS A60
PROGRAMMING
NETWORK (Example : NET = 3NBL)
x 1
x 1(1BL)
x 2 (2BL)
x 3 (3BL)
x 4 (3NBL)
x 5 (4BL)
x 6 (4 NBL)
x 1
confirm
14
DIRIS A60 - Ref.: 536 418 A GB
DIRIS A60
PROGRAMMING
x 1
x 1
x 1
x 1
x 1
confirm
NOMINAL VOLTAGE OF THE NETWORK (phase/phase) (Example: 4NBL: U=390V)
This value is used for calculating the sliding
reference voltage (Ureg) for the detection of the
voltage dips and interruption, as well as voltage
swell.
15
DIRIS A60 - Ref.: 536 418 A GB
DIRIS A60
PROGRAMMING
CURRENT TRANSFORMERS (Example : CT = 1500 / 5A).
Maxi 10000/5 ou 10000/1
x 2
x 1
x 1
confirm
16
DIRIS A60 - Ref.: 536 418 A GB
DIRIS A60
PROGRAMMING
VOLTAGE TRANSFORMER (Example : Vt = YES)
x 1
x 1
x 1
confirm
17
DIRIS A60 - Ref.: 536 418 A GB
DIRIS A60
PROGRAMMING
VOLTAGE TRANSFORMER PRIMARY (Example : PR = 20 000 V)
x 2
x 2
x 2
x 1
x 1
confirm
18
DIRIS A60 - Ref.: 536 418 A GB
DIRIS A60
PROGRAMMING
VOLTAGE TRANSFORMER SECONDARY (Example : SE = 110 V)
x 1
x 1 (110)
x 2 (115)
x 3 (120)
x 4 (173)
x 5 (190)
x 6 (60)
x 7 (100)
x 1
confirm
19
DIRIS A60 - Ref.: 536 418 A GB
DIRIS A60
PROGRAMMING
INTEGRATION PERIOD OF AVERAGE AND MAXIMUM CURRENTS
(Example : tIME 4I = 20 min)
x 1
x 1 (20 min)
x 2 (30 min)
x 3 (60 min)
x 4 (2 sec)
x 5 (10 sec)
x 6 (5 min)
x 7 (8 min)
x 8 (10 min)
x 9 (15 min)
x 1
confirm
20
DIRIS A60 - Ref.: 536 418 A GB
DIRIS A60
PROGRAMMING
INTEGRATION PERIOD OF AVERAGE AND MAXIMUM VOLTAGES
(Example : tIME U/V = 20 min)
x 1
x 1 (20 min)
x 2 (30 min)
x 3 (60 min)
x 4 (10 sec)
x 5 (5 min)
x 6 (8 min)
x 7 (10 min)
x 8 (15 min)
x 1
confirm
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Primare DIRIS A60 Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI