Mooney SBM20-267 Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Mooney SBM20-267 Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
SERV ICE BUL LE TINM20-267
IS SUE DATE: 1 No vem ber, 1998
SUB JECT:Parker- Hannifin, Air borne Vacuum Pump Flexi ble Cou pling Replacement
MOD ELS/S/N
AF FECTED: MOO NEY AIR CRAFT MOD ELS AND SE RIAL NUM BERS LISTED BE LOW:
M20J - S/N 24- 3423 thru 24- 3428
M20K - S/N 25- 2028 thru 25- 2031
M20R - S/N 29- 0148 thru 29-0161
TIME OF
COM PLI ANCE:Prior to IFR flight or within the next 60 days.
IN TRO DUC TION:Parker- Hannifin, Air borne Di vi sion, has is sued Serv ice Let ter Number 48, to ad vise
op era tors that a pre ma ture fail ure of the flexi ble cou pling may oc cur. It is rec om mende d that the flexi -
ble cou pling on above listed S/N air craft be re placed in ac cor dance with Air borne Serv ice L et ter Num -
ber 48 within the above time of compliance.
IN STRUC TIONS:
1.Re fer to Air borne Serv ice Let ter Num ber 48 for spe cific in spec tion and re place-
ment pro ce dures.
2.MAC rec om mends the fol low ing op era tional cau tions be used un til full com pli-
ance with Air borne Serv ice Let ter Num ber 48 has been done.
M20J and M20R -- On the above S/N air craft -- Dis able the Stand- by
Vac uum pump. Plac ard the Switch and the Cir cuit Breaker for the Stand-
by Vac uum Pump on each of the above listed S/N air craft.
On the S/N air craft listed above, the Pri mary Vac uum pump is ei ther ex-
cluded from Air borne’s S/N range or is from an other manu fac turer and is
unaf fected by the Air borne Serv ice Let ter.
M20K -- On the above S/N air craft -- Dis able the Stand- by Vac uum pump.
Plac ard the Switch and the Cir cuit Breaker for the Stand- by Vac uum
Pump on each of the above listed S/N airac raft.
Do not fly in IMC/IFR condi tions.
Both the Pri mary and the Stand- by Vac uum are af fected Air borne Pumps.
3.Com ply with Air borne Serv ice Let ter Num ber 48 as soon as pos si ble within
the time con straints of TIME OF COMPLIANCE.
WAR RANTY: Con tact Air borne Cus tomer Sup port at: (800) 382- 8422, or (440) 937- 1315, or
FAX (440) 937- 5409, or e- mail -- air [email protected], or con tact any
author ized Air borne dis tribu tor near you.
REF ER ENCE
DATA:Air borne Serv ice Let ter Num ber 48, date TBD.
PARTS LIST:Ref er ence Air borne Serv ice Let ter Num ber 48, date TBD.
FIG URES/
TA BLES:Ref er ence Air borne Serv ice Let ter Num ber 48, date TBD.
THIS SERV ICE BUL LE TIN IS FAA AP PROVED FOR EN GI NEER ING DE SIGN
/