Astria Fireplaces DRT4036/42 Instruction Sheet

Category
Fireplaces
Type
Instruction Sheet

This manual is also suitable for

Astria Fireplaces DRT4036/42 is a direct vent gas fireplace designed to provide supplemental heat to your home. It features a realistic flame pattern and glowing ember bed, creating a cozy and inviting atmosphere. The DRT4036/42 is available in two sizes, 36 inches and 42 inches, and can be installed in either a traditional or contemporary style. With its high efficiency rating, the DRT4036/42 can help you save money on your energy bills.

Astria Fireplaces DRT4036/42 is a direct vent gas fireplace designed to provide supplemental heat to your home. It features a realistic flame pattern and glowing ember bed, creating a cozy and inviting atmosphere. The DRT4036/42 is available in two sizes, 36 inches and 42 inches, and can be installed in either a traditional or contemporary style. With its high efficiency rating, the DRT4036/42 can help you save money on your energy bills.

Removing Barrier/Glass Door
Gloves must be worn when removing/replacing glass door. If glass
is broken, tape remaining glass frame before removing.
1. Remove bottom access panel.
2. Remove barrier by holding the barrier in front of the glass door
and slide it up into the channel underneath the upper front face
to release it from bottom channel then pull it out and away from
the fireplace (see Figure 1a, page 2).
3. Unlock 2 door latches on bottom of firebox.
4. Tilt open glass door 30° from bottom of firebox and lift up to
release door from firebox top retainer (see Figure 2, page 2).
5. To replace the barrier and glass door, reverse steps above.
WARNING: Reinstall any barrier removed before
operating the fireplace. The barrier is designed to
reduce the risk of burns from hot glass. Do not operate
the fireplace without the barrier installed.
IHP.US.com
This conversion kit must be installed by a qualified
service agency.
Read these instructions completely before installing this conversion kit.
Before proceeding, make sure gas control valve is in the OFF posi-
tion, all electrical power to the appliance is off and fireplace is cool
to the touch.
CAUTION: The gas supply shall be shut off prior to disconnect-
ing the electrical power before proceeding with the conversion.
Parts included with this kit:
Part No. Description Quantity
127175-01 Instruction Sheet 1
24771 Front Burner Orifice NG (#42) 2
23101 Rear Burner Orifice NG (#44) 2
127213-02 Conversion Label 1
106080-01 Conversion Information Label 1
123802-01 Gas Valve Regulator NG & Injector 1
Tools Required
3/8" Hex Socket Wrench or Adjustable Wrench
7/8" Open End Wrench or Adjustable Wrench
3/4" Open End Wrench or Adjustable Wrench
Slotted Screwdriver
Needle Nose Pliers
#2 Short Phillips Screwdriver
Thread Sealant (Resistant to Propane/LP)
ACCESSING FIREPLACE
The gas control valve and main burner orifice are located under firebox
floor of appliance and are accessed by removing bottom access door.
2 orifices are located in burners and are accessed by removing the
bottom access panel, barrier, glass door and burner.
Removing Bottom Access Panel
Remove bottom access panel by pulling top end forward and away
from appliance (see Figure 1). To replace removed item, reverse
procedure above.
Figure 1 - Removing Bottom Access Panel
Bottom Access
Door
Barrier
NCD-42S GAS CONVERSION KIT, PROPANE/LP GAS TO NATURAL GAS
[FOR USE WITH APPLIANCE MODELS SENTINEL42TEP & DRT4042TEP]
NCD-42S GAS CONVERSION KIT
PROPANE/LP GAS TO NATURAL GAS
P/N 127175-01
Rev. C, 10/2019
HEARTH PRODUCTS
KITS AND ACCESSORIES
Cat. No. Model Description
F1105 NCD-42S Gas Conversion LP to NG
IHP.US.com 127175-01_C
2
Grate
Base
Removable Logs
Burner
Base
Rear
Orice
Logset
Bulkhead
Fitting
BURNER ORIFICE CONVERSION
1. Remove andiron by lifting up and away from back of fireplace
(see Figure 3).
2. Carefully lift 3 loose logs from log stack.
3. Remove hex nuts that attach pilot shield and grate base to burner
base and 2 screws on side of pilot shield top.
4. Remove main burner from grate base by removing screw located
at right inner corner of firebox, and lifting up and toward the right
(see Figure 3).
5. Remove log set with grate base by holding sides of grate base
and lifting carefully to clear front burner orifice on right and pilot
shield on the left.
6. Remove LP orifice from elbow and bulkhead fittings. Apply a light
amount of propane/LP resistant sealant to threaded end of NG
orifices (#42 and 44) supplied with kit. Thread NG orifices into
fittings and tighten.
7. Adjust front burner air shutter and rear tube burner air shutter to
3/16" open position.
8. Reinstall log set with grate base, main burner and loose logs
removed in step 2, 3 and 4.
GAS CONTROL VALVE CONVERSION
Convert gas control valve by replacing valve regulator portion of
gas valve.
1. Partially press down and turn valve control knob to OFF position.
2. Remove 2 screws, regulator tower and diaphragm/spring com-
ponents.
3. Install new diaphragm/spring components, regulator tower and
2 screws from conversion kit.
4. Turn control knob to PILOT to light pilot. Turn control knob to ON.
5. Leak test with leak detection solution with main burner ON.
Note: in replacement and conversion use only new parts provided.
When converting to different gas you must also change pilot and
burner orifices.
Main
Burner
Andiron
Assembly
Pilot
Shield
Top Pilot
Shield
Front
Orice
Elbow
Fitting
Air
Shutter
Figure 3 - Removing Orifice for Conversion (Valve Shown
Removed from Base for Clarity
Figure 1a - Removing Barrier
Channel
Barrier
Frame
Slot
Figure 2 - Removing Glass Door
Glass Door
Door Latch
IHP.US.com
127175-01_C 3
Figure 4 - Removing Mounting Screws, Pressure Regulator
Tower and Diaphragm/Spring Components Mounting
Lighting Instruction Plate
Conversion Label
Pilot
Bracket
Pilot Hood
Pilot
Orice
Pilot Barrel
Pilot Clip
Figure 5 - Apply Conversion Labels over Existing Certification
Label on Lighting Instruction Plate
CONVERSION LABELING AND PLACEMENT
1. Apply conversion label over top of existing certification label (see
Figure 5). Existing certification label is located on lighting instruc-
tions plate inside gas valve compartment area. With permanent
ink, print previous model number on label in space provided (see
Figure 6).
2. After filling data required on conversion information label (see
Figure 7), affix it to floor of appliance where it is easily seen when
bottom access door is removed.
Conversion Label
VENTED GAS FIREPLACE
Conversion Kit Model
Type of Gas
Previous Model #
PFS
®
Figure 6 - Print Previous
Model Number on
Conversion Label
Figure 7 - Conversion
Information Label
PILOT ORIFICE CONVERSION
1. Remove pilot hood from barrel using tweezers or needle nose
pliers to open clips (see Figure 8).
2. Remove pilot orifice from inside barrel with slotted screwdriver.
3. Replace pilot orifice with orifice supplied with this kit. Insert open
end of new pilot orifice inside barrel and thread pilot orifice with
slotted screwdriver.
4. Reinstall pilot hood into barrel then install clip to secure pilot
hood.
IMPORTANT: Be careful not to bend or kink aluminum tubing
during conversion. Make sure pilot hood and orifice are properly
mated and aligned after finishing this conversion.
Figure 8 - Converting Pilot Orifice
CONVERSION INFORMATION LABEL
This appliance was converted on
___ - ___ - ___ to ______________ gas
with Kit No. _______________________
by _____________________________
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
(name and address of organization making
this conversion), which accepts the
responsibility that this conversion has been
properly made.
106080-01
Day Month Year
Mounting
Screws
Pressure
Regulator
Tower
Diaphragm/
Spring
Components
FINAL PREPARATION
1. Leak check gas control and any connections you've made be-
fore operating appliance. Refer to Checking Gas Connections in
owner's manual.
2. Reinstall glass door and close latches.
3. Replace barrier and reinstall bottom access panel.
The conversion is now complete.
To operate your fireplace, refer to Operating Fireplace in your appli-
ance owners manual.
WARNING: Test all gas piping and connections,
internal and external to unit, for leaks after installing
or servicing. Correct leaks at once.
WARNING: Never use an open flame to check for
a leak. Apply noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak. Correct all
leaks at once.
WARNING: This conversion kit shall be installed
be a qualified service agency in accordance with the
manufacturer's instructions and all applicable codes
and requirements of the authority having jurisdiction.
If the information in these instruction is not followed
exactly, a fire, explosion or production of carbon mon-
oxide may result causing property damage, personal
injury or loss of life. The qualified service agency is
responsible for the proper installation of this kit. The
installation is not proper and complete until the opera-
tion of the converted appliance is checked as specified
in the manufacturer's instructions supplied with the kit.
You may have further questions about installation, operation, or
troubleshooting. Please contact your IHP dealer for any questions or
concerns. When contacting your dealer please have the model and
serial numbers of your fireplace ready.
You can also visit our web site at IHP.US.com.
TECHNICAL SERVICE
Innovative Hearth Products reserves the right to make changes at any time, without notice, in
design, materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.
Printed in U.S.A. © 2014 Innovative Hearth Products LLC
P/N 127175-01 Rev. C 10/2019 1769 East Lawrence Street • Russellville, AL 35654
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Astria Fireplaces DRT4036/42 Instruction Sheet

Category
Fireplaces
Type
Instruction Sheet
This manual is also suitable for

Astria Fireplaces DRT4036/42 is a direct vent gas fireplace designed to provide supplemental heat to your home. It features a realistic flame pattern and glowing ember bed, creating a cozy and inviting atmosphere. The DRT4036/42 is available in two sizes, 36 inches and 42 inches, and can be installed in either a traditional or contemporary style. With its high efficiency rating, the DRT4036/42 can help you save money on your energy bills.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI