Lunos Silvento surface-mounted Installation guide

Type
Installation guide
1
DE Einbauanleitung
Silvento Aufputz-Gehäuse
- Bitte an den Nutzer weiterleiten -
EN Installation Manual
Silvento Surface–Mounted
Housing
- Please pass on to user -
2
1
2
3
4
5
6
DE Hinweise 3
EN Hints 3
7
DE Abmessungen 4
EN Dimensions 4
DE Einbaubeispiele 4
EN Installation examples 4
DE Liefereinheiten 5
EN Delivery units 5
DE Montage 6
EN Assembly 6
DE Elektrischer Anschluss 8
EN Elektrical connection 8
DE Filterwechsel 8
EN Filter replacement 8
8DE Textteil / Beschreibung 9
EN Text part / description 14
3
2,25 m
1 1
0
2
1 2
0
4
8/BA
269 mm
58 mm
109,5 mm
69 mm
79 mm
260 mm
58,5 mm
2
3
5
40078
V-EC
4
39152
3/AP-B
39144
3/AP
8/BA
6
5.1
5.2
Ø 5,5 mm
5.3
5.4
(A)
Ø 6 mm
5.5
5 3/AP
3/AP-B
7
L2
L1
N
L
F+
F-
(A)
12 mm 40 mm
6 mm
(C)
(C)
(D)
(F)
(E)
AP
5.6
5.7 5.8
5.9
8
6.1 6.2
6.3
(R)
6.4
(R)
5/W
LED
6.5
6
TAC
5/W2
3 s
(S)
7
9
Inhalt: Seite:
Zu dieser Anleitung, Sicherheitshinweise, Einsatzbereich, Entsorgen 9
Technische Daten, Hinweise 10
Einbaubeispiele, Versandeinheiten 11
Montage - Gehäuse und elektrischer Anschluss 11
Montage - Ventilatoreinsatz und Designblende 11
Elektrischer Anschluss 12
Filterwechsel, Reinigung, Zusatz und Austauschteile 13
Einbauanleitung DE
8
Lesen Sie vor Montage diese Anleitung sorgfältig und vollständig durch! Beachten Sie unbedingt
die allgemeinen Sicherheitshinweise und die Sicherheitssymbole mit Hinweisen im Text
Diese Anleitung ist nach Abschluss der Montage an den Nutzer (Mieter, Eigentümer, Hausverwal-
tung usw.) weiterzugeben
Zeichen in dieser Anleitung:
Dieses Zeichen warnt Sie vor Verletzungsgefahren
Dieses Zeichen warnt Sie vor Verletzungsgefahren durch Elektrizität
Vorsicht! Jede Montagearbeit am Lüftungsgerät darf nur bei abgetrennter Netzspan-
nung erfolgen!
Achtung! Der elektrische Anschluss darf nur von autorisiertem Fachpersonal und
nach gültiger VDE 0100 vorgenommen werden!
Achtung! Dieses Gerät darf nicht von Kindern und Personen bedient werden
(Filterwechsel/ Reinigung), die aufgrund ihrer physischen, sensorischen oder geistigen
Fähigkeiten oder ihrer Unerfahrenheit oder Unkenntnis nicht in der Lage sind, es sicher zu
bedienen.
Bei Ventilatoren für Abluftbetrieb muss immer für eine funktionierende Nachströmung von
Außenluft gesorgt werden
Temperatureinsatzbereich: - 15°C bis + 40°C
Einsetzbar bei einer relativen Luftfeuchte bis 75% im Innenraumbereich (nicht kondensierend, kurz-
zeitiges Überschreiten bei laufendem Lüfter zulässig). Bei Überschreitung der Einsatzgrenzen Gerät
ausschalten. Frischluftzufuhr durch Fensterlüftung sicherstellen.
Entsorgen Sie die Verpackung sortenrein. Wenn Sie sich vom Lüftungsgerät trennen
möchten, entsorgen Sie es zu den aktuellen Bestimmungen. Im Rahmen des Elektro-und
Elektronikgerätegesetzes (ElektroG) ist die kostenlose Rückgabe dieses Gerätes bei Ihrer
kommunalen Sammelstelle gewährleistet.
Zu dieser Anleitung
Sicherheitshinweise
Einsatzbereich
Entsorgen
10
Funktion/Steuerplatine 5/EC-ZI (90) 5/EC-FK (90) 5/EC-FK+ (90)
Volumenstrom Grundlast (DIP 1,2)
Volumenstrom Bedarf (DIP 6,7)
Einschaltverzögerung (-/45/120s) (/ / ) (/ / ) ( - / - / -)
Nachlaufzeit (-/15/30 min) (/ / ) (/ / ) ( - / - / -)
Intervallbetrieb
(-/4h30min/2h15min) (/ / ) (/ / ) ( - / - / -)
Feuchte/Temperatur Sensor ( - / - / -) (/ ) (/ )
VOC Sensor (Gerüche) - -
CO2 äquivalente Regelung - -
LED Filterwechselanzeige
0-10 V Steuereingang
Datenlogging
Optional Funkmodul FM-EO oder
Bewegunsgmelder 5/BM (/ ) (/ ) (/ )
Diagnosesoftware PC basiert
Technische Daten
Spannungsversorgung: 200-240 V AC 50/60 Hz
Fernsteuereingang: 0-10 V DC
Schutzklasse: II
Schutzart: IPX5
Luftvolumenstrom: AUS, 15-60/90* m³/h
Elektrische Leistungsaufnahme: 1,8-6,2/14,5* W
Schalldruckpegel: 22 35/44* dB(A)
(bei aktiver Feuchteregelung quasi-stufenlos zwischen 15 und 60/90* m³/h)
*je nach Steuerplatine
Jeder Silvento ec kann mit einer Steuerplatine ohne Feuchtesensor oder mit Feuchtesensor kombi-
niert werden, jede Steuerplatine ist mit jeweils einem Erweiterungsmodul kombinierbar.
Daraus ergeben sich folgende Konfigurationsmöglichkeiten:
15/20/30/40/45/45/50/60 (90) m³/h
15/20/30/40/45/45/50/60 m³/h
Optional verfügbar und hier nicht aufgeführt ist die Steuerplatine für die Kellerlüftung 5/EC-KE.
Wir informieren Sie gerne.
Alle Geräte sind ausgestattet mit Filter der Klasse G2 und einer Filterwechselanzeige.
Lüftungsgeräte der Typenreihe Silventoerfüllen alle Anforderungen:
- für Niederspannung (CE) nach EG Richtlinien (2006/95/EG; 2014/35/EU)
- für elektromagnetische Verträglichkeit (CE) nach EG Richtlinien (2004/108/EG; 2014/30/EU)
Die Kennlinie der Stufe 60 m³/h ist Bestandteil der DIBt Zulassung Z-51.1-215 und kann dieser ent-
nommen werden. Die Kennlinie ist ebenfalls mit allen weiteren Kennlinien in einem separaten Doku-
ment zusammengefasst, das unter www.lunos.de heruntergeladen werden kann.
Die Ventilatoren der Baureihe Silvento ec sind in Kombination mit den oben aufgeführten Platinen
konfigurierbar und im Volumenstrom kalibrierbar. Eine Anleitung ist ebenfalls und www.lunos.de zu
finden.
Die in den Begleitdokumenten genannten Volumenströme beziehen sich auf den eingebauten Zu-
stand unter Berücksichtigung einer korrekten Auslegung/Planung und entsprechenden Einbaus.
11
3/AP ohne Brandschutz-Absperrvorrichtung
5.1 Lage der Rückschlagklappe entsprechend der gewählten Einbaulage überprüfen und gege-
benenfalls korrigieren. Stutzen mit Rückschlagklappe zur Korrektur durch Drehen lösen und
entsprechend Abbildung 5.2 wieder einsetzen
3/AP-B mit Brandschutz-Absperrvorrichtung 8/BA
5.3 Befestigungslöcher bohren und Dübel einsetzen (dazu Bohrschablone benutzen,
Oberkante waagerecht ausrichten)
5.4 Brandschutz-Absperrvorrichtung montieren
Die Lage der Rückschlagklappe muss der gewählten Einbaulage entsprechen.
(Siehe Abbildung 5.2)
Gehäusemontage
5.5 Kabeltülle (A) abschneiden (Wasserdichtheit beachten, siehe auch Abbildung 5.6) und Netz
kabel einführen.
Netzkabel als Schlaufe hinter das Gehäuse legen und das Gehäuse mit den beiliegenden
Schrauben an der Schachtwand befestigen.
Achtung! Netzkabel spannungsfrei machen!
Netzanschluss
5.6 Netzkabel wie dargestellt abmanteln und abisolieren.
Netzanschlussklemme (C) entsprechend des gewählten Anschlussbildes (siehe 6) montie-
ren. Zur leichteren Montage kann die Netzanschlussklemme durch Drücken in Richtung der
Gehäusewand entnommen werden.
5.7 Netzanschlussklemme einrasten
5 Montage - Gehäuse und elektrischer Anschluss
- Der Einbau im Bereich 1 und 2 in Bade- und Duschräumen entsprechend VDE 100 ist zulässig.
- Lüftereinbau als Dunstabzugshaube nicht gestattet
- Bei veränderte Einbaulage gegebenenfalls Lage der Rückschlagklappe korrigieren (siehe Bild 5.2)
- Innerhalb der schraffierten Bereiche darf sich kein Netzkabel befinden.
1 Hinweise
4 Versandeinheiten
Bei Brandschutz muss die Schachtwand die geforderte Feuerwiderstandsdauer besitzen!
3 Einbaubeispiele
Ventilatoreinsatz Silvento V-EC inklusive:
Filterrahmen mit Filter
Designblende
Schraubenzubehör
Einbauanleitung
Produktdatenblatt und Energielabel
Aufputzgehäuse inklusive:
Stutzen mit Rückschlagklappe
Netzanschlussklemme
Bohrschablone
Einbauanleitung
Schrauben und Dübel
Montage Ventilatoreinsatz
5.8 Ventilatoreinsatz fest einrasten und am Netzanschlussbereich (D) anschrauben. Achten Sie
dabei auf einen sauberen Sitz des Motoranschlusskabels innerhalb der dafür vorgesehenen
Führung.
Montage Designblende
5.9 Rastöffnungen (AP) im Filterrahmen (E) freimachen (sind mit APgekennzeichnet). Filter
rahmen auf dem Gehäuse einrasten und Filter einlegen. Designblende (F) aufsetzen und
einrasten.
5 Montage - Ventilatoreinsatz und Designblende
12
Zusätzliche Installationen und elektrische Bauelemente im Lüftungsgerät sind unzulässig!
Anschlussbilder für weitere Lüfterfunktionen auf Anfrage!
Vorsicht! Jede Montagearbeit am Lüftungsgerät darf nur bei abgetrennter Netzspannung erfol-
gen! Das Lüftungsgerät ist schutzisoliert nach Schutzklasse II, der Schutzleiteranschluß
entfällt.
Machen Sie vor Anschluss des Lüftungsgerätes an die Netzspannung alle Anschlussleitungen
spannungsfrei! (Abtrennung vom Netz mit mindestens 3 mm Kontaktöffnung, z.B. elektr. Si-
cherung).
Jeder zum Lüfter gehörende Stromkreis muss mit einem Fehlerstromschutz (z. B. FI– Schal-
ter) ausgestattet sein!
Elektrischer Anschluss nur durch Fachmann!
Hinweis: Eine Vielzahl von Lüftungsfunktionen des Silvento ec lassen sich über die in der
Steuerplatine dieses Typs integrierten DIP-Schalter und über mögliche Zusatzmodule realisieren.
Entnehmen Sie bitte diese Informationen der Einbauanleitung E186 Ventilatoreinsatz Silvento ec“.
6 Elektrischer Anschluss
6.1 Automatischer Betrieb mit Feuchteregelung/Grundlüftung entsprechend DIP-Schalterstellung
der Steuerplatine.
Komfortplatine: feuchtegeregelter Betrieb
Basisplatine: Intervallschaltung möglich
6.2 Mit Fernsteuerung (0 - 10 V)
Der Fernsteuereingang ist in zwei Bereiche aufgeteilt. Im Bereich 0-5 V wird die Stufe abso
lut, d.h. mit höchster Priorität gesetzt (entspricht DIP 6,7 bei geschaltetem L1). Im Bereich 6-
10 V wird nur die Grundlast gesetzt (entspricht DIP 1,2). Im Bereich 0-0,4 V arbeitet der Lüf-
ter eigenständig.
Stufe 0: 0,6 V - 0,9 V
Stufe 1: 1,1 V - 1,4 V
Stufe 2: 1,6 V - 1,9 V
Stufe 3: 2,1 V - 2,4 V
Stufe 4: 2,6 V - 2,9 V
Stufe 5: 3,1 V - 3,4 V
Stufe 6: 3,6 V - 3,9 V
Stufe 7: 4,1 V - 4,4 V
Stufe 8: 4,6 V - 4,9 V
Stufe 1: 6,1 V - 6,4 V
Stufe 2: 6,6 V - 6,9 V
Stufe 3: 7,1 V - 7,4 V
Stufe 4: 7,6 V - 7,9 V
Stufe 5: 8,1 V - 8,4 V
Stufe 6: 8,6 V - 8,9 V
Stufe 7: 9,1 V - 9,4 V
Stufe 8: 9,6 V - 9,9 V
Bereich absolute
Stufe Bereich Grund-
laststufe
6.3 Je nach Steuerplatine, DIP-Schalterstellung und Modul:
Mit Zeitnachlauf (Basisplatine): Deaktivieren der Nachlauffunktionen (L2), Dauerbetrieb
Grundlüftung oder AUS entsprechend DIP-Schalter 1 und 2 schaltbar auf Bedarfslüftung
(L1) entsprechend DIP-Schalter 6 und 7.
Mit Feuchteregelung (Komfortplatine): Deaktivierbare Feuchteregelung (L2), schaltbar auf
Bedarfslüftung (L1)
Hinweis: Keine Lichtkopplung bei VDE-konformer Installation möglich
((R) Brücke)
6.4 Je nach Steuerplatine, DIP-Schalterstellung und Modul:
Einstufiger Betrieb, schaltbar auf Bedarfslüftung
Dauerbetrieb Grundlüftung und zeitnachlaufgesteuerte Bedarfslüftung
Feuchteregelung, schaltbar auf Bedarfslüftung
Zeitnachlaufgesteuerte Bedarfslüftung
Hinweis: Verwenden Sie einen zweipoligen Schalter, wenn die Raumbeleuchtung
gleichzeitig mit der Bedarfslüftung geschaltet werden soll!
6.5 Direkter Anschluss an die TAC mittel Niederspannungseingang F+ und F-.
13
Wischen Sie bei Bedarf Designblende und Gitterabdeckrahmen mit einem trockenen weichen Tuch
ab.
Filterwechsel und Reinigung dürfen nicht von Kindern und Personen durchgeführt werden, die
aufgrund ihrer physischen, sensorischen oder geistigen Fähigkeiten oder ihrer Unerfahrenheit
oder Unkenntnis nicht in der Lage sind, diese sicher durchzuführen.
Filter im 3er Pack 2/FSI-R Bestell-Nr.: 39721
Basisplatine 5/EC-ZI Bestell-Nr.: 40080
Komfortplatine 5/EC-FK Bestell-Nr.: 40081
Komfortplatine plus 5/EC-FK+ Bestell-Nr.: 40217
Basisplatine bis 90 m³/h 5/EC-ZI90 Bestell-Nr.: 40126
Komfortplatine bis 90m³/h 5/EC-FK90 Bestell-Nr.: 40127
Komfortplatine plus bis 90 m³/h 5/EC-FK 90+ Bestell-Nr.: 40221
Platine für Kellerlüftung 5/EC-KE Bestell-Nr.: 40133
Bewegungsmelder 5/BM Bestell-Nr.: 40082
7.1 LED leuchtet dauerhaft bei verschmutztem Filter. Designblende abnehmen, Filter entnehmen
und neuen oder gereinigten Filter einlegen. Die Reinigung des Filters kann z.B. mit dem
Geschirrspüler erfolgen.
Taster (S) mit Finger oder Hilfsmittel z. B. Stift 3 Sekunden betätigen. Die LED erlischt.
Achtung! Gerät niemals ohne Filter betreiben.
7 Filterwechsel
Reinigung
Zusatz-/ Austauschteile
14
About These Instructions, Safety Instructions, Range of Application, Disposal 14
Technical Data, Notes 15
Installation Examples, Shipping Units 16
Installation - Housing and Electrical Connection 16
Installation - Fan Insert and Decor Screen 16
Electrical Connection 17
Filter Change, Cleaning, Additional Parts and Replacement Parts 18
Read these instructions carefully and completely before executing assembly work! General safety
instructions and the safety symbols with respective notes in the text must be observed.
These instructions are to be passed on to the user after completing assembly work (tenant, own-
er, building administration etc.).
Symbols in these instructions
This symbol warns of a risk of injury
This symbol warns of a risk of injury from electricity
Caution! Any installation work on the ventilation unit may only be carried out with the mains
voltage disconnected!
Attention! Electrical connections must be carried out by authorized qual ified staff in
accordance with applicable VDE 0100!
Attention! This device must not be operated by children or persons (filter change/
cleaning) who are not able to operate it safely on account of their physical, sensory or mental
capacity or due to their inexperience or lack of skills.
When using fans for exhaust air operation, a properly working fresh air flow must always be
ensured.
Temperature application range: - 15°C to + 40°C
Can be used at a relative air humidity of up to 75% indoors (non-condensing; temporary exceedance
with the fan running is permissible). The user is requested to switch off the unit if the application
limits are exceeded. Ensure fresh air supply by window ventilation.
Dispose of packaging correctly sorted. If you wish to dispose of the device, observe appli-
cable conditions. Within the framework of the German Electrical and Electronic Equipment
Act (ElektroG), the free return of this device to your municipal collection point is guaran-
teed.
Contents Page:
Installation Instructions EN
About These Instructions
Safety Instructions
Range of Application
Disposal
8
15
Technical Data
Power supply: 200-240 V AC 50/60 Hz
Remote control input: 0-10 V DC
Protection class: II
Protection type: IPX5
Air volume flow: OFF, 15-60/90* m³/h
Electrical power consumption: 1.8-6.2/14.5* W
Sound pressure level: 22-35/44* dB(A)
* depending on the control board
Function/Control Board 5/EC-ZI (90) 5/EC-FK (90) 5/EC-FK+ (90)
Volume flow base load (DIP 1,2)
Volume flow demand (DIP 6,7)
Switch-on delay (-/45/120s) (/ / ) (/ / ) ( - / - / -)
Follow-up time (-/15/30 min) (/ / ) (/ / ) ( - / - / -)
Interval operation
(-/4h30min/2h15min) (/ / ) (/ / ) ( - / - / -)
Humidity / temperature sensor ( - / - / -) (/ ) (/ )
VOC Sensor (smells) - -
CO2 equivalent operation - -
LED filter change indicator
0-10 V control input
Data logging
Optional Radio Module FM-EO or
Motion Detector 5/BM (/ ) (/ ) (/ )
Diagnostic tool PC based
15/20/30/40/45/45/50/60 (90) m³/h
15/20/30/40/45/45/50/60 m³/h
Every Silvento ec can be combined with a control board without a humidity sensor or with a humidity
sensor, each control board can be combined with one extension module.
This results in the following configuration options:
The Control board for the basement ventilation 5/EC-KE is optionally available and not listed here.
We will be pleased to inform you.
All units are equipped with class G2 filters and a filter change indicator.
Ventilation units of the "Silvento" series meet all requirements:
- for low voltage (CE) according to EG guidelines (2006/95/EG; 2014/35/EU)
- for electromagnetic compatibility (CE) according to EC directives (2004/108/EC; 2014/30/EU)
The characteristic curve of the level 60 m³/h is part of the DIBt approval Z-51.1-215 and can be taken
from it. The characteristic curve is also summarized with all other characteristic curves in a separate
document that can be downloaded from www.lunos.de.
The fans of the Silvento ec series can be configured in combination with the circuit boards listed
above and the volume flow can be calibrated. Instructions can also be found at www.lunos.de.
The volume flows specified in the accompanying documents refer to the installed condition, taking
into account correct design/planning and corresponding installation.
16
3 Installation Examples
4 Shipping Units
For fire protection, the shaft wall must have the required fire resistance duration!
Fan insert Silvento V-EC including:
Filter frame with filter
Decor Screen
Screw accessories
Installation Manual
Product data sheet and energy label
All wall installation housings including:
Nozzle with non-return valve
Mains connection terminal
Drilling template
Installation Manual
Screws and dewels
5 Installation - Housing and Electrical Connection
3/AP without fire protection shut-off device
5.1 Check the position of the non-return valve according to the selected installation position and
correct it if necessary. Loosen the nozzle with the non-return valve by turning it for correction.
(see figure 5.2)
3/AP-B with fire protection shut-off device 8/BA
5.3 Drill fixing holes and insert dowels (using the drilling template, align upper edge horizontally)
5.4 Installing the kitchen fire protection
The position of the non-return valve must be according to the selected installation position.
(see figure 5.2)
Housing installation
5.5 Cut off cable grommet (A) (observe water tightness, see also figure 5.6) and insert power
cable.
Place the power cable as a loop behind the housing, fasten the housing to the shaft wall
using the screws provided.
Attention! Disconnect the mains cable from the power supply!
Power connection
5.6 Strip the power cable as shown.
Mount the mains connection terminal (C) according to the selected connection diagram (see
6). To facilitate the installation, the mains connection terminal can be removed by pressing it
in the direction of the housing wall.
5.7 Snap the mains connection terminal into place.
5 Installation - Fan Insert and Decor Screen
Mounting the fan insert
5.8 Snap the fan insert firmly into place and screw on the mains connection area (D). Make sure
that the motor connection cable is properly seated within the guide provided for it.
Attention: Do not operate the one-room fan without sound insulation
Mounting the decor screen
5.9 Clear the snap openings (AP) in the grille frame (P) (they are marked "AP")
Snap the grill framewith filter onto the housing. Put on the front cover and snap it into place.
1 Notes
- Installation in area 1 in bath and shower rooms in accordance with VDE 100 is permissible
- Fan installation for use as extractor hood not permitted
- Correct position and tight fit of the non-return valve if necessary (see Figure 5.7).
- Do not place a power cable within the hatched areas.
17
Note: A variety of Silvento ec ventilation functions can be created using the DIP switches
integrated in the control board of this type and via optional add-on modules. For this information,
please refer to the "Fan Insert Silvento ec Installation Manual ".
Additional installations and electrical components in the ventilation unit are not permitted!
Connection diagrams for further fan functions available on request!
Caution! Any installation work on the ventilation unit may only be carried out with the mains
voltage disconnected! The ventilation unit is insulated in accordance with protection class II, a
protective conductor connection is not required.
Make sure all connection lines are de-energized before connecting the ventilation unit to the
power supply! (Disconnection from power supply with at least 3 mm contact opening, e.g.
fuse)
Each circuit connected to the ventilation system must be fitted with residual current protection
(e.g. RCD switch)!
Electrical connections must be carried out by qualified staff only!
6.1 Automatic operation with humidity control according to DIP switch position of the
control board.
Comfort control: Humidity controlled operation
Basic control: Interval switching possible
6.2 With remote control (0 - 10 V)
The remote control input is divided into two ranges. In the range of 0-5 V the level is
set absolutely, i.e. with highest priority (corresponds to DIP 6,7 with switched L1 ). In the
range of 6-10 V only the base load is set (corresponds to DIP 1,2). In the range of
0-0.4 V the fan operates autonomously.
6.3 Depending on the control board, DIP switch position and module:
With run-on time (basic control): Deactivation of the run-on functions (L2), conti-
nuous operation basic ventilation or OFF according to DIP switches 1 and 2 swit-
chable to regulated ventilation (L1) according to DIP switches 6 and 7
With humidity control (comfort control): Humidity control can be deactivated (L2),
switchable to regulated ventilation (L1)
Note: No light coupling possible with VDE-compliant installation
((R) Bridge)
Step 0: 0,6 V - 0,9 V
Step 1: 1,1 V - 1,4 V
Step 2: 1,6 V - 1,9 V
Step 3: 2,1 V - 2,4 V
Step 4: 2,6 V - 2,9 V
Step 5: 3,1 V - 3,4 V
Step 6: 3,6 V - 3,9 V
Step 7: 4,1 V - 4,4 V
Step 8: 4,6 V - 4,9 V
Step 1: 6,1 V - 6,4 V
Step 2: 6,6 V - 6,9 V
Step 3: 7,1 V - 7,4 V
Step 4: 7,6 V - 7,9 V
Step 5: 8,1 V - 8,4 V
Step 6: 8,6 V - 8,9 V
Step 7: 9,1 V - 9,4 V
Step 8: 9,6 V - 9,9 V
Area
absolute
level
Base load
level area
6 Electrical Connection
18
6.4 Depending on control board, DIP switch position and module:
Single-stage operation, switchable to regulated ventilation
Continuous operation basic ventilation and run-on time-controlled regulated ventila-
tion
Humidity control, switchable to regulated ventilation
Run-on time-controlled regulated ventilation
Note: Use a two-pole switch to switch the room lighting simultaneously with the
regulated ventilation!
6.5 Direct connection to TAC via F+ and F-.
7.1 The LED lights up continuously when the filter is dirty.
Remove the front cover, remove the filter. Insert a new or cleaned filter. The filter can be
cleaned e.g. using a dishwasher.
Press the button (S) with a tool, e.g. a pen, for 3 seconds; the LED goes out.
Put the front cover back in place.
Never operate the unit without a filter!
When necessary, wipe the front cover and grille frame using a dry soft cloth.
Filter change and cleaning must not be carried out by children or persons who are not able to
operate the unit safely on account of their physical, sensory or mental capacity or due to their
inexperience or lack of skills.
Pack of 3 filters 2/FSI-R Order no.: 39721
Control board basic variant 5/EC-ZI Order no.: 40080
Control board comfort variant 5/EC-FK Order no.: 40081
Control board comfort plus 5/EC-FK+ Order no.: 40217
Control board basic variant up to 90 m³/h 5/EC-ZI90 Order no.: 40126
Control board comfort variant up to 90 m³/h 5/EC-FK90 Order no.: 40127
Control board comfort plus up to 90 m³/h 5/EC-FK 90+ Order no.: 40221
Control board for basement ventilation 5/EC-KE Order no.: 40133
Motion detector module 5/BM Order no.: 40082
Radio module 5/FM –EO Order no.: 40083
Additional Parts and Replacement Parts
7 Filter Change
Cleaning
19
Notes
20
LUNOS Germany
LUNOS Lüftungstechnik GmbH & Co. KG Phone +49 30 362 001-0
für Raumluftsysteme Fax +49 30 362 001-89
Wilhelmstr. 31 [email protected]
13593 Berlin Germany www.lunos.de
E97 12.22
Notes
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Lunos Silvento surface-mounted Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI