INSTRUCTIONS for
METER KIT, P/N 34722
for
HELIARC 250
AC/DC Power Source
This optional meter kit provides accurate indication of open-circuit and welding voltage, and welding current in AC or
DC modes. This module is designed for easy installation at top-front of the power supply.
To install the meter kit:
1. Remove right panel of power source (as viewed from front panel). Above the top-right circuit board locate the black
circular plug (P16) which will be tied to the wire harness. Carefully untie (P16) from the harness.
2. On the top panel, remove the hole plug near the front of the lift eye, and remove the screw in the center of top
(front) panel. Place the module on the top panel so that the receptacle in the bottom of the module protrudes
through the top panel hole. Replace the screw through the flange of the module and tighten. The module is now
securely mounted to the power source.
3. Orient (P16) to the receptacle in the module, push (P16) into receptacle and tighten locking collar by turning fully
clockwise.
4. Replace right panel of power source, which completes METER KIT installation.
METER KIT SPARE PARTS LIST
Part No. Qty. Description
950817 1 Meter, 0-400 Amperes
950816 1 Meter, 0-80 Volts
674993 1 Meter P.C. Board Ass’y.
F-15-050-A 3/95