5.2>.The second line display over voltage protection OVP value.The default
value is 31V and it can be reset.
5.3>.The third line display over current protection OCP value.The default
value is 2.1A and it can be reset.
5.4>.The fourth line display over power protection OPP value.The default
value is 15.5W and it can be reset.
5.5>.The fifth line display over discharging protection OPH value.The default
value is 000:00h. It means turn OFF this function.
5.6>.The sixth line display over capacity protection OAH.The default value is
00.000Ah. It means turn OFF this function.
6>.The Fourth Page:
6.1>.Display module supports fast charging protocols and current USB
supported protocol and then module’s default fast charging mode.
7>.The Fifth Page:
7.1>.The first line display current work mode. The work mode can be selected
from PER, VAH and PWM.
7.2>.The second line display current LCD brightness.It can be selected from
BL0~BL5.
7.3>.The third line display current temperature unit and check value.The
temperature unit can be Celsius and Fahrenheit. Check value can be -10℃~10℃
or -18F~18F.
7.4>.The fourth line display current power on state.It can be selected as ON
or OFF.
7.5>.The fifth line display current background color and font color of Menu
Line. They are available in 8 colors in each parameters.
7.6>.The last line display measured voltage and measured current which can
not be set in this page.
10.PWM Mode:
1>.PWM mode can has 5 display interface. It can be switch display by DOWN or
UP button.
2>.Menu Line: The first line is the page prompt line.It can display current work
mode PER and current display page.
3>.The First Page:
3.1>.Power Main Interface.
3.2>.It can display output frequency, output duty cycle, output voltage, work
mode, temperature C or F, ON/OFF status.
3.3>.The last line display output voltage and output current which can not be
set.
3.4>.The built-in temperature is displayed by default. If an external
temperature sensor is connected, the temperature area shows a blue background.
3.5>.It has three work mode:NOR/FIN/PUL. NOR and FIN mode display
output frequency, output duty cycle, output voltage. PUL mode display Position
Pause Time P-T, Negative Pause Time N-T, Pause Number P-P, Pulse Amplitude