Marantec EM 110 Owner's manual

Type
Owner's manual

Marantec EM 110 is an expansion module that enhances the functionality of the Control x.plus control unit. It offers additional features such as signal light control, potential-free radio contact, and extended levels of programming options. With this module, you can customize the operation of your door system to suit your specific needs, improving convenience and security.

Marantec EM 110 is an expansion module that enhances the functionality of the Control x.plus control unit. It offers additional features such as signal light control, potential-free radio contact, and extended levels of programming options. With this module, you can customize the operation of your door system to suit your specific needs, improving convenience and security.

Expansion module EM 110
Manual for installation and operation
GB
2 Manual for installation and operation, Expansion module EM 110 GB (#85967)
2. Table of contents
Caution!
Danger of personal injury!
The following safety advice must be
observed at all times so as to avoid
personal injury!
Attention!
Danger of material damage!
The following safety advice must be
observed at all times so as to avoid
material damage!
Advice / Tip
Check
Reference
i
Advice
1. Meaning of symbols . . . . . . . . . .2
2. Table of contents . . . . . . . . . . . .2
3. General safety advice . . . . . . . . .3
4. Product overview . . . . . . . . . . . .5
4.1 Supply package . . . . . . . . . . . .5
4.2 Dimensions . . . . . . . . . . . . . . .5
5. Installation . . . . . . . . . . . . . . . . .6
5.1 Install expansion module . . . . .6
5.2 Wiring of the expansion
module . . . . . . . . . . . . . . . . . .6
6. Programming . . . . . . . . . . . . . .10
6.1 Functions of the module . . . .10
6.2 Extended levels of the
Control x.plus control unit . .14
7. Attachment . . . . . . . . . . . . . . . .15
EC Declaration of Conformity . . . . . . .15
1. Meaning of symbols
Manual for installation and operation, Expansion module EM 110 GB (#85967) 3
3. General safety advice
Target group
This product may only be installed, connected and put into operation by qualified and trained professionals!
Qualified and trained specialist personnel are persons
- who have knowledge of the general and special safety regulations,
- who have knowledge of the relevant electro-technical regulations,
- with training in the use and maintenance of suitable safety equipment,
- who are sufficiently trained and supervised by qualified electricians,
- who are able to recognise the particular hazards involved when working with electricity,
- with knowledge regarding applications of the EN 12635 standard (installation and usage requirements).
Warranty
For an operations and safety warranty, the advice in this instruction manual has to be observed.
Disregarding these warnings may lead to personal injury or material damage. If this advice is disregarded,
the manufacturer will not be liable for damages that might occur.
To avoid installation errors and damage to the device, it is imperative that the installation instructions are
followed. The product may only be operated after reading these installation and operating instructions.
The installation and operating instructions are to be given to the door system user, who must keep them
safe. They contain important advice for operation, checks and maintenance.
This item is produced according to the directives and standards mentioned in the Manufacturer's
Declaration and in the Declaration of Conformity. The product has left the factory in perfect condition with
regard to safety.
Power-operated windows, doors and gates must be checked by an expert (and this must be documented)
before they are put into operation and thereafter as required, but at least once a year.
Correct use
The expansion module expands the Control x.plus control unit.
Beside the advice in these instructions, please observe the general safety and accident
prevention regulations!
Our sales and supply terms and conditions are effective.
Please read carefully!
3. General safety advice
Installation tips
• Ensure that the devices to be connected (doors etc.) are in a mechanically faultless state.
• Before commencing cabling works it is very important to disconnect the system from the electricity supply.
Ensure that the electricity supply remains disconnected throughout the cabling works.
• Adhere to the local protection regulations.
• Lay the electricity supply cables and control cables; these MUST be laid separately.
The operating voltage is 24 V.
Information on cleaning the operator system
Never use water jets, high pressure cleaners, acids or bases for cleaning.
Please read carefully!
4 Manual for installation and operation, Expansion module EM 110 GB (#85967)
4.1 Supply package 4.2 Dimensions
1 Expansion module
2 Cable harness for module connection
1
4. Product overview
Manual for installation and operation, Expansion module EM 110 GB (#85967) 5
4.1 / 1
2
4.2 / 1
126
46
48
A
6 Manual for installation and operation, Expansion module EM 110 GB (#85967)
Designation
Type / function
A Operating indicator
B Display for output XH19B
C Display for output XH19A
D
Display for control element
activated
XB59 Control element connections
XB41A
Connection of Control x.plus
control unit
XB41B Connection of further module
XH19A Connection of signalling device
XH19B Connection of signalling device
5.1 Install expansion module 5.2 Wiring of the expansion
module
5. Installation
• Fit the expansion module (B) in the type 4 /
type 5 (A) expansion housing type.
5.2.1 Overview of the module connections
5.1 / 1
A
5.2.1 / 1
B
C
D
XB59
XB41A
XH19A
XH19B
XB41B
B
Manual for installation and operation, Expansion module EM 110 GB (#85967) 7
5. Installation
5.2.2 Connection of the modules
XB41A
• Connect the Control x.plus control unit to the
connecting socket XB41A.
• Connect further modules to socket XB41B as
required.
5.2.2 / 1
XB41B
Connection of the control unit and a further
module
8 Manual for installation and operation, Expansion module EM 110 GB (#85967)
5. Installation
Advice:
To activate the module, a single com-
mand must be given via the connec-
tion XB59 (impulse to B5-8). As a
result further menus in the Control
x.plus control unit will be activated.
Reference:
The activated menus are described in
section 6.2.
i
-XB59
-SB8
13 14
-SB4
13 14
-SB47
13 14
-SB6
13 14
B5 8 4 47 6
5.2.2 / 2
Designation
Type / function
SB8 Operating button for IMPULSE*
SB4
Operating button
intermediate CLOSE position*
SB47 Has no function
SB6 Operating button for OPEN**
Connection of control element (XB59)
M08E002
* The function sequence is programmable in
level 8 / menu 6 of the Control x.plus control
unit.
** The function “active without stop” is not
modifiable through level 8 / menu 5.
-XH19A
-HH94
H1 92 94
L1
N
Manual for installation and operation, Expansion module EM 110 GB (#85967) 9
Connection for signal light (XH19B)
Connection for signal light (XH19A)
-XH19B
-HH94
H1 92 94
L1
N
5.2.2 / 4
M08E002
Designation
Type / function
HH94 Signal light supplied by customer
XH19A Connection of signalling device
Designation
Type / function
HH94 Signal light supplied by customer
XH19B Connection of signalling device
92
94
H1
5.2.2 / 3
M08E002
92
94
H1
5. Installation
Attention!
To avoid damage being caused to the
circuit board, the contact loading
(max. 230 V / 0.5 A) must be
observed.
6. Programming
10 Manual for installation and operation, Expansion module EM 110 GB (#85967)
6.1 Functions of the module
6.1.1 Functions of the module
* Identification plate
** Terminal block
Example 1
XH19A**
XH19B**
Control EM 110 Typ A 1 0 / G 2 0*
Door not in intermediate OPEN position: signalling device OFF
Door in intermediate OPEN position: signalling device illuminated
Function: door in intermediate OPEN position
If door stationary: signalling device OFF
If door is moving: signalling device flashes
Function: door in motion
Example 2
XH19A**
XH19B**
Control EM 110 Typ E 2 0 / J X X*
No further adjustment possible
No further adjustment possible
Function: signal light (level 3 / menu 7)
Door not in OPEN position: signalling device OFF
Door in OPEN position: signalling device illuminated
Function: door in OPEN position
Manual for installation and operation, Expansion module EM 110 GB (#85967) 11
6. Programming
* Identification plate
** Terminal block
Example 3
XH19A**
XH19B**
Control EM 110 Typ L 1 X / K X X*
No further adjustment possible
No further adjustment possible
Function: lighting (level 5 / menu 4)
No further adjustment possible
1: ON/OFF
Function: potential-free contact (level 4 / menu 8)
6. Programming
12 Manual for installation and operation, Expansion module EM 110 GB (#85967)
Function
Programming in the
Control x.plus control
unit
Adjustment of functions
A Door in motion - Refer to section 6.1.3
B Door moves to OPEN - Refer to section 6.1.3
C Door moves to CLOSED - Refer to section 6.1.3
D Door in any intermediate position - Refer to section 6.1.3
E Door in intermediate OPEN position - Refer to section 6.1.3
F Door in CLOSED door position - Refer to section 6.1.3
G Door in intermediate OPEN position - Refer to section 6.1.3
H Door in intermediate CLOSED position - Refer to section 6.1.3
I Motor starts - Wiping impulse
J Signal light Level 3, menu 7 -
K
Lighting (door in motion +
lighting duration)
Level 5, menu 4 -
L Potential-free radio contact Level 4, menu 8
0 Wiping impulse
1 ON / OFF
M Problem - Refer to section 6.1.3
N Maintenance indicator - Refer to section 6.1.3
6.1.2 Function table
Manual for installation and operation, Expansion module EM 110 GB (#85967) 13
6. Programming
6.1.3 Table of values
Function fulfilled Function not fulfilled
0 OFF 1 flashing
0 OFF 2 illuminated
1 flashing 0 OFF
1 flashing 2 illuminated
2 illuminated 0 OFF
2 illuminated 1 flashing
X
No further
adjustment
possible
X
No further
adjustment
possible
14 Manual for installation and operation, Expansion module EM 110 GB (#85967)
6. Programming
Level 4 – Remote programming
Menü 8: Potential-free contact
LED 7 flashes slowly -> press the hand transmitter button -> LED 7 flashes quickly
Level 5 – Special function
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 4: Lighting duration (in seconds)
OFF 5 10 15 20 25 30 35 40 50 80 100 120 150 180 255
Advice:
Potential-free contact by radio is only available if the module has the identification code LOX
or L1X on the corresponding connection.
Advice:
The lighting duration is only available if the module has the identification code KXX on the
corresponding connection.
6.2 Extended levels of the Control x.plus control unit
An activated module results in the menus which follow in the Control x.plus control unit being activated.
Manual for installation and operation, Expansion module EM 110 GB (#85967) 15
EC Declaration of Conformity
We hereby declare that the product sold by us
and mentioned below corresponds in its design,
construction and version to the relevant and basic
health and safety requirements of the following
EC regulations: EMC Directive, Machinery Directive
and Low Voltage Directive.
Product changes made without our consent will
render this Declaration void.
Product:
Relevant EC Regulations:
- EC EMC Directive
(89/336/EEC),
- Machinery Directive
(98/37/EEC) and
- Low Voltage Directive
(73/23/EEC and 93/68/EEC).
Applied harmonised standards, in particular:
EN 292-1 / EN 61000-6-2 / EN 61000-6-3 /
EN 55014 / EN 61000-3-2 / EN 61000-3-3 /
EN 60335-1 / EN 60335-2-95 / EN 12445 /
EN 12453 / EN 300220-1 / EN 301489-3 /
ETS 300683
Date / Signature
7. Attachment
English Copyright.
No part of this manual may be reproduced without our prior consent.
Subject to changes which are in the interest of technical improvements.
Version: 05.2008
#85 967
1 - GB/KD 36-0286 - M - 0.5 - 0508
85967
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Marantec EM 110 Owner's manual

Type
Owner's manual

Marantec EM 110 is an expansion module that enhances the functionality of the Control x.plus control unit. It offers additional features such as signal light control, potential-free radio contact, and extended levels of programming options. With this module, you can customize the operation of your door system to suit your specific needs, improving convenience and security.