Savant SPM-H2FPD10-01, SPM-Q2FPD10-01 Reference guide

  • Hello! I am an AI chatbot trained to assist you with the Savant SPM-H2FPD10-01 Reference guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
009-1485-01 | 191031 45 Perseverance Way, Hyannis MA 02601
Copyright © 2019 Savant Systems, LLC 1 of 2 Savant.com | 508.683.2500
A
B
C
F
E
D
A
Multi-Page LCD screen can display the following:
Energy usage in watts at the output.
Percentage of brightness at the output.
Firmware, Mac Address, and FCC/IC information.
Real time Bluetooth status connectivity icon.
B
PAIR Button - This is a multi-use button. How the button is
pressed will determine its function:
Press and Release - Cycles through the various screens on
the LCD (POWER > DIMMER > INFO 1 > INFO 2).
Press and hold - Press and hold for 2 seconds to put module
into pairing mode. Press and hold for 3 seconds to reset.
C
Manual Load Switches - Toggle switch to ON position to
switch load on. Toggle switch to AUTO for normal operation.
Switch A controls output A and Switch B controls output B.
D
Input Power Connection - Connect the 120V AC output
from the companion breaker to this input.
E
Output Connections - Connections are labeled OUTPUT A
and OUTPUT B. Connect each output to a separate load.
See the Wiring section (page 2).
F
Neutral Wire - Connect to the neutral bar in breaker panel.
See the Wiring section on page 2.
Minimum Supported Release
Savant OS da Vinci 9.0
Terminals
Screw Tighten
Torque
1.34 Nm
Wire /
Conductor Type
Copper (Cu) only
Supported Load Types
Standard
Configuration
Dimmable circuits – Incandescent, halogen,
magnetic low-voltage transformer, and forward
phase dimmable fluorescents
Standards
Wireless
Bluetooth Low Energy (BLE)
2.4 GHz radio frequency
Regulatory
Safety and
Emissions
FCC Part 15 UL ICES 003
Contains FCC ID: 2AA9B04
Contains IC: 12208A-04
RoHS Compliant
Recommended Load Center Types
All Homeline™ compatible modules fit into 1-inch load centers.
All QO™ compatible modules fit into
¾ inch load centers
Power
Inputs
120V AC @ 60 Hz, 15 Amps (max)
Load Power
(max)
300VA 2.5A @ 120V AC per channel
600VA 5.0A @ 120V AC per channel (when
just one channel is used)
Features of
Automatic
Action
Type 1.Y action
Dimensions and Weights
Height Width Depth Weight
Module
(Homeline)
1.98 in.
(5.03 cm)
4.87 in.
(12.37 cm)
2.80 in.
(7.11 cm)
.5 lbs
(.23 kg)
Module
(QO)
1.48 in.
(3.76 cm)
5.00 in.
(12.70 cm)
2.63 in.
(6.68 cm)
.5 lbs
(.23 kg)
Environmental
Temperature 32° to 104° F (0° to 40° C)
Humidity 5% to 85% Relative Humidity (non-condensing)
Location Indoor Use Only
Features
Control capability for dimming two loads up to 300 VA (volt-
ampere). See the table in the section below.
All QO™ and Homeline™ lighting modules are compatible with
Schneider Electric Square D™, QO™, and Homeline™ load centers.
Modules are forward phase (leading edge) type dimmers.
Built-in energy monitoring; +/- 3% accuracy / 1 sec sample time.
Color LCD display for easy identification and load status.
Output Power Maximums
Dual 300W Forward Phase Companion Module Dimmer
Installation Manual
Specifications
Box Contents
Descriptions
(1) Forward Phase Dimmer Module
SPM-Q2FPD10-00 QO™ Style Dimmer Module -or-
SPM-H2FPD10-00 Homeline™ Style Dimmer Module
(1) Product Information and Regulatory Insert (009-1710-xx)
(1) Quick Reference Guide (this document)
Dimmer Type Incandescent MLV LED
Forward Phase 300W 240W Not Recommended
The maximum output in watts is shown below for the dierent
dimmer/load combinations. Use this table for reference when
determining the number of loads that can be connected to each
output on the dimming module.
Additional Documentation
Panel Bridge Controller Quick Reference Guide (009-1740-xx)
Savant Panelized Lighting Deployment Guide (009-1823-xx).
Dual 500W Adaptive Phase Companion Module Dimmer
Installation Manual (009-1486-xx).
Dual 20 Amp Relay Companion Module Installation Manual (009-
1484-xx).
Dual 30A 240VAC 2-Pole Relay Companion Module Installation
Manual (009-1483-xx)
009-1485-01 | 191031 45 Perseverance Way, Hyannis MA 02601
Copyright © 2019 Savant Systems, LLC 2 of 2 Savant.com | 508.683.2500
ELECTRIC SHOCK! The 120V AC, 60 Hz source poses an
electrical shock hazard that has the potential to cause serious injury
to installers and end users.
IMPORTANT! A licensed electrician is required to install Savant
Lighting Companion Modules.
1. At the breaker panel, switch o the main breaker so there is no
power supplied to the panel.
2. Position and install a breaker into one of the slots in the panel.
Press firmly until the breaker is fully seated onto the appropriate
bus bars.
3. Position and install the Companion Module into the slot
where it will be installed. Press firmly until fully seated onto
the appropriate bus bars. Typically the Companion Module is
installed alongside the breaker.
HELPFUL! In a 3-phase breaker panel, an adaptive phase
dimmer module and the breaker that feeds the module must
be installed onto the same phase in the panel. Failure to do
so will result in damage to the module.
4. Connect the neutral wire (white wire) from the module to the
neutral bus bar in the panel.
5. Use the wiring diagram below to complete the wiring.
Installation into Breaker Panel
Wiring
Important Information Circuit Test Instructions
To determine the size (wattage) of the breaker feeding each set
of Companion Modules do the following:
1. Determine the wattage requirements of each load connected
to a Companion Module.
2. Sum up the wattage of all loads.
3. Divide the wattage requirements by the input voltage. This
will be the current being drawn.
Sum up the number of spaces needed for the breaker and the
dimming and relay modules. Each breaker requires one space
and each Companion Module requires two spaces.
Maximum number of modules that can communicate with the
Panel Bridge Controller is 40.
The total current draw from the loads can’t exceed 80% of the
size of the breaker for that circuit. For example, with 15 amp
breaker, 12 amps or 1440 watts. With a 20 amp breaker, max
would be 16 amps or 1920 watts.
Do not add MLV and ELV type loads to the same breaker/
Companion Module circuit. MLV and ELV loads should be
connected to separate breaker circuits. Doing so can cause
damage to the dimming module.
Use the diagram below when making connections between the Companion Module, associated breaker, and load(s). Additional diagrams are
available in the Savant Panelized Lighting Deployment Guide. When making connections, common electrical practices should be followed.
BREAKER
OUTPUT OUTPUT
B
A
INPUT
CIRCUIT POWER
ON
AUTO
PAIR
A B
FORWARD PHASE
DIMMER
OUTPUT OUTPUT
B
A
INPUT
CIRCUIT POWER
ON
AUTO
PAIR
A B
FORWARD PHASE
DIMMER
Neutral Bar
Neutral Bar
To Gnd Bar
To Gnd Bar
When connecting to an ARC
fault type breaker, connect
the neutral wire from the
load to the neutral screw.
The neutral on an ARC fault
type breaker is either a
pigtail wire, or a plug-on
neutral bus bar connection.
Ground Bar
ARC FAULT
CIRCUIT
STANDARD
CIRCUIT
BREAKER
OUTPUT OUTPUT
B
A
INPUT
CIRCUIT POWER
ON
AUTO
PAIR
A B
FORWARD PHASE
DIMMER
OUTPUT OUTPUT
B
A
INPUT
CIRCUIT POWER
ON
AUTO
PAIR
A B
FORWARD PHASE
DIMMER
Use AFCI / GFCI protection where
required by local regulations
The instructions below can be used to test that the Companion
Breaker Modules are functioning correctly. The setup requires the
following:
Forward Phase Companion Dimmer Module.
Resistive loads with maximum amperage of 2.5 Amps.
15 amp circuit breaker.
Neutral bus bar
120V AC source
To complete this test, follow the instructions below. Refer to the
wiring diagram when making connections.
1. Connect neutral pigtail from the module to a neutral bus bar.
2. Connect the output of a 15A circuit breaker (120VAC) to the
INPUT connection on the module. Wire must be at least 4 inches
(10.1 cm) in length.
3. Connect a resistive load to Output A.
4. Connect a second resistive load to Output B.
5. Connect the unused side of each load to the neutral bus bar.
6. Toggle the CIRCUIT POWER switches A and B to the ON position
7. Connect 120V AC to the hot connection on the rear of the
module (not shown in diagram).
8. To test, apply 120V AC to the HOT connection on the rear of the
companion module. The loads will switch on. Toggle the CIRCUIT
POWER switches to AUTO and verify the loads switch o.
PANEL CIRCUIT
BREAKER
15A
OUTPUT OUTPUT
B
A
INPUT
CIRCUIT POWER
ON
AUTO
PAIR
A B
FORWARD PHASE
DIMMER
Neutral Bus Bar
Neutral pigtail wire from
the companion module
Resistive Load A
2.50 Amps
Resistive Load B
2.50 Amps
1
2
3
4
5
6
/