Page 3
JAG-9
100 Series
0.17 OSIG 1 OSIG 4 OSIG 8 OSIG 12 OSIG 16 OSIG 20 OSIG
200 Series
0.17 OSIG 0.5 OSIG 2 OSIG 4 OSIG 6 OSIG 8 OSIG 10 OSIG
Input Capacity
10
3
BTU/hr
90 200 390 550 680 785 880
Excess Air (%) 1,000 2,000 3,500 5,000 5,000 5,000 4,500
Flame Length (in) In TubeIn Tube26688
Input Capacity
10
3
BTU/hr
100 300 535 725 875 1,000 1,120
Excess Air (%) 1,500 2,500 5,000 7,000 7,000 7,000 7,000
Flame Length (in) In Tube In Tube 6 6 6 12 16
Input Capacity
10
3
BTU/hr
125 290 600 850 1,060 1,250 1,310
Excess Air (%) 4,500 5,000 5,000 7,000 7,000 7,500 7,500
Flame Length (in) In TubeIn Tube6 10121216
Input Capacity
10
3
BTU/hr
230 560 1,050 1,440 1,810 2,075 2,300
Excess Air (%) 2,500 3,500 5,000 7,500 7,500 7,500 7,500
Flame Length (in) 6 121216181824
Input Capacity
10
3
BTU/hr
555 1,062 2,364 3,166 3,619 4,150 4,584
Excess Air (%) 2,500 2,500 3,500 3,500 4,000 4,000 4,000
Flame Length (in) In Tube In Tube 6 8 12 16 24
SVG280C-JAG BURNER STATIC PRESSU
0.11 OSIG 0.43 OSI
2.9 OSIG 5.4 OSIG 9 OSIG 12 OSIG 15 OSIG
Input Capacity
10
3
BTU/hr
800 1,618 4,180 5,700 7,374 8,515 9,520
Excess Air (%) 2,500 2,500 3,500 5,000 7,500 7,500 7,500
Flame Length (in) 12 24 24 30 36 36 42
0.7 mbar 2 mbar 9 mbar 17 mbar 26 mbar 35 mbar 43 mbar
Input Capacity (kW) 24 53 103 145 180 207 232
Excess Air (%) 1,000 2,000 3,500 5,000 5,000 5,000 4,500
Flame Length (m) In Tube In Tube 0.05 0.15 0.15 0.20 0.20
Input Capacity (kW) 26 79 141 191 231 264 296
Excess Air (%) 1,500 2,500 5,000 7,000 7,000 7,000 7,000
Flame Length (m) In Tube In Tube 0.15 0.15 0.15 0.30 0.41
Input Capacity (kW) 33 76 158 224 280 330 346
Excess Air (%) 4,500 5,000 5,000 7,000 7,000 7,500 7,500
Flame Length (m) In Tube In Tube 0.15 0.25 0.30 0.30 0.41
Input Capacity (kW) 61 148 277 380 478 548 607
Excess Air (%) 2,500 3,500 5,000 7,500 7,500 7,500 7,500
ame
engt
m
0.15 0.30 0.30 0.41 0.46 0.46 0.61
Input Capacity (kW) 147 280 624 836 955 1,096 1,210
Excess Air (%) 2,500 2,500 3,500 3,500 4,000 4,000 4,000
Flame Length (m) In Tube In Tube 0.15 0.20 0.30 0.41 0.61
0.5 mbar 2 mbar 13 mbar 23 mbar 39 mbar 52 mbar 65 mbar
Input Capacity
kW
211 427 1,104 1,505 1,947 2,248 2,513
Excess Air (%) 2,500 2,500 3,500 5,000 7,500 7,500 7,500
Flame Length (m) 0.30 0.61 0.61 0.76 0.91 0.91 1.07
NOTES:
1. Capacities based on Natural Gas with HHV of 1034 BTU/ft
(Standard), and LHV of 36.74 MJ/nm3 (Metric), 0.59 S.G.,
and a stoichiometric ratio of 9.74:1 with burner firing into chamber under no pressure at 10% excess air.
2. Excess air based on 2V or higher, flame signal via a Honeywell 7800 series Burner Control
3. Flame lengths measured from end of flame protection tube.
SVG_80C-
JAG
SVGE80C-
JAG
JAG BURNER CAPACITIES
METRIC
SVGE60C-
JAG
SVGE20C-
JAG
SVGE25C-
JAG
SVGE30C-
JAG
SVGE40C-
JAG
BURNER
BURNER STATIC INLET AIR PRESSURE
JAG BURNER CAPACITIES
STANDARD
BURNER
BURNER BURNER STATIC INLET AIR PRESSURE
SVG_20C-
JAG
SVG_25C-
JAG
SVG_30C-
JAG
SVG_40C-
JAG
SVG_60C-
JAG
C. CAPACITIES
Table 1. Burner Capacities