IXIO-DT3 /-DP3
12-24 V
AC-DC
IXIO-DT3
INTERFACE
BELL1
12-24 V
AC-DC
INTERFACE
DOOR BELL
1
2
IXIO-DT3
3
*
*
*
A
B
* max. 800 mA
* max. 800 mA
LCD
LCD
BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 |
[email protected] | WWW
.BEA.BE
©BEA | User’s Guide | 42.8209 / V2 - 12.14
DOOr bell InTerface
Relay or frequency output is used to open the door:
connect YE/BK and WH/BK wires to the door bell
+ turn the switch down.
The LED will be blue and the LCD shows «bell1» when the
door bell is activated.
Current output is used to open the door:
connect YE and WH wires to the door bell
+ turn the switch up.
The LED will be green and the LCD shows «door
bell» when the door bell is activated.
PLUG THE IXIO DOOR BELL INTERFACE
USE THE FREE OUTPUT WIRES TO CONNECT THE DOOR BELL
CHOOSE THE DOOR BELL DURATION VIA LCD (0.05 s - 5 s)
Max. switching voltage: 30 V DC / 27 V AC
Max. switching current: 0.8 A
Overvoltage protection for inductive loads
No overcurrent protection
EN
YE
WH
YE/BK
WH/BK
YE
WH
YE/BK +
WH/BK -
INSIDE
WHEN DOES THE DOOR BELL RING?
The door bell is activated when the inside radar detects
a person who enters after crossing both inside infrared
curtains.
If the door bell rings when a person leaves the building,
increase the radar angle slightly towards the interior.
door bell rings
door bell does not ring