Aiphone AT-406B/A Installation & Operation Manual

Category
Telephone handsets
Type
Installation & Operation Manual

This manual is also suitable for

1–
HAND
S
ET INTER
COM
Models
;
AT
-406
,
Boxed
S
e
t
AT
-406
P,
Displa
y
pack
S
e
t
AT
-306
,
Add
-on
sub
AT-406B
A
Boxed Set
tt
c
harcoal gray colo
r
83096400 0602 F
F
2
2
2
2
NAME
S
& FEATURE
S
AIPHONE
AT-206
CA
LL
AT-206
master
Battery check
LED
CALL button
Battery
compartment
AIPHONE
AT-306
C
ALL
AT-306
sub
CALL button
F
ea
t
u
r
es
2
-
h
an
d
set commun
i
cat
i
on s
y
stem
suited
f
or
:
R.V. cab-to-camper, Boat deck-to-cabin
,
Limo. chauffer to back seat
,
an
d
Restaurant kitchen to bar, etc
.
U
p to 3 su
bs
Electronic call tone, not ad
j
ustabl
e
Front loadin
g
batterie
s
Battery or DC power suppl
y
External signaling devic
e
1
AT
-406
i
s a
H
an
d
set
I
ntercom set, a
ll
ow
i
ng two-way ca
lli
ng
&
commun
i
cat
i
on
.
AT
-306 Add-on sub
(
add’l 2
p
cs max.
)
P
ower supp
ly:
S
KK-62
0
in U
S
A, P
S
-6D
,
P
S
-6
M
i
n Europe, or 4 pcs
S
UM-3(AA) batteries
.
TAR
-
3
r
elay for external si
g
nalin
g
device. Powered by a separate 6V D
C
power supply
.
C
om
p
onents availabl
e
A
T-406
B
oxed se
t
A
T-4
06P
Display pack set (N/A in USA
)
A
T-4
06
B
/A
B
exed set, charcoal gray colo
r
1
1
1
1
S
Y
S
TEM
O
UTLINE &
CO
MP
O
NENT
S
P
ackage
C
ontent
s
Handset Intercom set
(
A
T-406,AT-406P
,
AT-4
06
B
/A
)
or Sub station
(
AT-
306
)
M
ount
i
ng
b
rac
k
e
t
P
ac
k
e
t of
sc
r
e
w
s
Installation &
O
peration Manua
l
2
AT-206 AT-306
PS6
Batteries
or
22
AT-306AT-306
33
3
I
N
S
TALLATI
ON
External s
i
gnal
i
ng dev
i
c
e
Any particular station can be si
g
naled by bell or li
g
ht, while it rin
g
s
.
I
nstal
l
TAR-
3
relay powered by its own 6V DC power supply
(
SKK-620
,
P
S
-
6
D o
r
P
S
-
6M
).
TAR-3
Black(–)
Red(+)
Orange(2)
pwr.
BlueWhite
AT-206
B
1
2
AT-306
1
2
PS6
TAR-3
Black(–)
Red(+)
Orange(2)
pwr.
Blue
White
AT-206
B
AT-306
1
2
1
2
PS6
Mountin
g
AT-406 set is desi
g
ned
f
or indoor use only. Do not install outdoors
.
I
t must be used in wall-mounted applications only
.
Wirin
g
AT-406 can be wired with 2 non-polarized wires. When add-on sub(s
)
is installed, connect in loop or home run. Keep audio wires 50cm, 20
a
way from any AC wirin
g
, fluorescent li
g
hts, dimmer switches, etc
.
AIPHONE
AT-206
CALL
AIPHONE
AT-206
CALL
Cover
Loading batterie
s
S
lide down front battery cover. Place four
S
UM-3 (AA
)
b
atteries into compartment. Observe polarity
.
B
attery LED indicato
r
1
.
LED
i
s
b
r
i
g
h
t
l
y
li
t
.
B
atteries are power
f
ul enou
g
h
.
2.
B
ecomes
di
m
d
ur
i
n
g
use
.
B
atteries are
g
ettin
g
weaker
.
3. LED is no lon
g
er lit
.
Batteries are exhausted. Re
p
lac
e
a
ll four batteries with new ones
.
IN
S
TALLATI
O
N &
O
PERATI
O
N MANUA
L
Warning
(Negligence could result in death or serious injury to people)
Do not connect any power source other than specified to
terminals +,
. Do not connect AC wires to any terminal
on any unit. Fire or unit damage could result.
Do not dismantle or alter the intercom.
When placing the batteries inside the compartment, observe
polarity as marked inside. If batteries are damaged,
fire, injury, or contamination to environment may result.
For DC powered systems, use Aiphone power supply model specified with
system. If non-specified product is used, fire or malfunction could result.
Precautions
The intercom station is designed for indoor use and for wall
-mounting only.
Do not install the intercom in any of the following locations,
as it may cause the system to malfunction:
High or extreme cold temperature area: under direct
sunlight, near equipment that varies in temperature, in front of
air-conditioner, inside a refrigerated area, etc.
Places subject to moisture or humidity extremes.
Places subject to environmental conditions, such as oil,
dust, chemicals, salt, etc.
Places subject to constant vibration or impact.
Places subject to steam or smoke, such as near heating
appliances, cooking surface, etc.
General Precautions
Caution
(Negligence could result in injury or damage to property.)
Do not manually hold hook switch down while holding handset, as
the call tone sounds very loud through handset receiver,
and can cause your hearing damage.
Mount the intercom on wall in a convenient location, but not
where it could be bumped or jarred. Injury could result.
General prohibitions
Prohibitions to dismantle the unit
Prohibitions to subject the unt to water
4
– 2 –
4 WIRING
W
ARRANT
Y
Aiphone warrants its products to be
f
ree
f
rom de
f
ects o
f
material and workmanship under normal use and service
f
or a period o
f
on
e
y
ear a
f
ter delivery to the ultimate user and will repair
f
ree o
f
char
g
e or replace at no char
g
e, should it become de
f
ective up
o
n
whic
h
examination shall disclose to be de
f
ective and under warranty. Aiphone reserves unto itsel
f
the sole ri
g
ht to make the
f
inal d
e
c
isio
n
whether there is a defect in materials and
/
or workmanship; and whether or not the product is within the warranty
.
This warranty shall not apply to any Aiphone product which has been subject to misuse, ne
g
lect, accident, or to use in violatio
n
of
instructions
f
urnished, nor extended to units which have been repaired or altered outside o
f
the
f
actory. This warranty does n
o
t
cove
r
batteries or dama
g
e caused by batteries used in connection with the product
.
This warranty covers bench repairs only, and any repairs must be made at the shop or place desi
g
nated in writin
g
by Aiphone
.
Aiphone will not be responsible
f
or any costs incurred involvin
g
on site service calls
.
AIPHONE CO., LTD., NAGOYA, JAPA
N
AIPH
O
NE
CO
RP
O
RATI
O
N, BELLEVUE, WA, U
SA
AIPH
O
NE EUR
O
PE N.V.
,
ANTWERP
,
BEL
G
IU
M
N
P: Non-polarize
d
PS6
:
6V DC power suppl
y.
S
KK-
6
2
0
: (+) Red, (–) Black
.
PS
-
6D
: (+) Red, (–) White
.
PS
-
6M
AT-206 AT-306
PS6
AT-306AT-306
1
2
+
---
1
2
1
2
1
2
NP NPNP
55
5
M
OU
NTIN
G
M
ount t
h
e
i
ntercom on
b
rac
k
et, a
lig
n
i
n
g
at t
h
e mar
k
s.
P
u
ll
d
ow
n
on
b
rac
k
et, unt
il
i
t proper
l
y
l
oc
k
s.
T
erm
i
na
l
sect
i
on
i
s on t
h
e
b
ac
k
s
ide. Do not disassemble the unit. For surface wall cable run
,
outlet hole is
p
rovided on the to
p
or bottom of chassis
.
83.5mm,
3-5/16"
Mounting
bracket
Marks
DC wires
Single-gang
box
2 screws
supplied
AT-206
AT-306
66
6
O
PERATION
S
P
ress CALL button to call sub station(s)(max. 3 subs). Sub station rin
g
s master station only. It rin
g
s as lon
g
as CALL button
i
s pressed
.
Communicate on handsets.At conclusion, replace handset onto cradle. If not hun
g
up, battery power is consumed
.
External si
g
nalin
g
device, connected to astation, is activated as lon
g
as call tone rin
g
s on handset
.
7
7
7
7
7
TE
C
HNI
C
AL PRE
C
AUTI
O
N
S
When batteries are exhausted, replase all
f
our batteries with new ones
.
C
lean AT-406 with a soft cloth dampened with neutral household cleanser. Never use an
y
abrasive cleaner or cloth
.
8
8
8
8
S
PE
C
IFI
C
ATI
O
N
S
(
AT-406
)
P
ower source
:
6
V D
C
, 150mA. 0A standby
.
P
ower supp
l
y
:
S
KK-620 in U
S
A, P
S
-6D or P
S
-6M power supply.
O
r 4 pcs
S
UM-3(AA) batteries
.
C
ommunication
:
Electronic tone rin
g
s opponnent station(s).
C
ommon talk system with handsets
.
• W
i
r
i
ng
:
2 w
i
res
p
ara
ll
e
l
, non-
p
o
l
ar
i
ze
d.
• Wiring distance
:
Diameter 0.65mmø 1.0mmø AWG 22AWG 18AWG
2-station 700m 1,600m 2-station 2,300’ 5,300’
3
x AT-
306
s
400m 940m
3
x AT-
306
s
1,300’ 3,100’
• D
i
mens
i
ons & we
ig
ht
:
21
0
H x
80
W x
5
1D.
8
-1
/
4”H x
3
-1
/8
”W x 2”D
.
AT-206: 310
g
(0.68 lbs.) approx
.
AT-306: 280
g
(0.62 lbs.) approx
.
0.65mmø
700m
22AWG
2,300’
P
rinted in Ja
p
an
(
E
)
D
o not use a power supp
l
y w
h
en
b
atter
i
es ar
e
i
nsta
ll
e
d
.
h
ttp://www.aiphone.com
/
AT-206
master
AT-306
sub1
CALLING
CALLING
CALLING
CALLING
AT-306
sub2
AT-306
sub3
  • Page 1 1
  • Page 2 2

Aiphone AT-406B/A Installation & Operation Manual

Category
Telephone handsets
Type
Installation & Operation Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI