  • Hello! I am an AI chatbot trained to assist you with the ALLEGION Von Duprin 4754 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
*941035-00*
941035-00
Note: Use lock washers on top and
bottom mullion ttings except
for counter sunk screws.
1. Line up and install bottom mullion
tting with center of door
opening and ush with closed
doors (Figure 1 or 2).
2. Wire top mullion tting and
mullion. Test assembly. See
wiring diagram opposite
side of sheet.
3. Line up and install top mullion
tting with center of door
opening and ush with closed
doors. See Figure 5 (reverse
side) for optional frame conditions.
4. Cut mullion body to length as
shown in Figure 6.
Note: Do not cut mullion cable.
5. Insert mullion in top tting and
slide bottom of mullion into
place. See Figure 6 (reverse side).
6. Nest mullion into bottom tting
and secure set screw.
7. Install top mullion clamp over
mullion and tting with mounting
screws. See Figure 6 (reverse side).
8. Adjust strikes for 1/32 clearance
between latch bolt and strike.
See Figure 6 (reverse side).
3 15/32
3/16” R. typ.
F-Flat sill tting shown
Figure 1
Top anchor
1/4-20 X 5/8” B.H.M.S.
2
Threshold must be
cut to t around
the at sill tting
Figure 2
2 3/8
2 7/8”
1 3/16
1/16” ref.
Door opening
Door opening
1 7/16
1 11/16
9/16
Cut o top end of mullion body
so length is 1/16” less than this dimension.
C
L
C
L
Figure 4
2
Figure 3
Door opening
C
L
Disconnect Mullions
4754 & 4854
Installation Instructions
© Allegion 2014
Printed in U.S.A.
941035-00 Rev. 01/14-b
Customer Service
1-877-671-7011 www.allegion.com/us
Reinforcement
Filler block is to be
supplied by the frame
mfg. for conditions
similar to this
For stops wider than 3 1/2”
1 7/16
3/4
Dia.
Clearance
Reinforcement
Top clamp
Bottom
set screw
Figure 6
5/16 - 18” Anchor
Note: Reinforcement for all
sheet metal frames is
to be supplied by
frame mfg.
15/16
Figure 5
Reinforcement
Note: The application of the
strike depends on the
device it is to be used with
C
L
Latch bolt
and strike
5/16 - 18 X 1/4”
F.P.H.M.S. - S.S.
sekirtS sekirtS
sekirtS
sekirtS sekirtS
/