Optimus MESSENGERG2XL User manual

Type
User manual

This manual is also suitable for

M-Control Remote Software
and
Lobe Assembler Software
for
Messenger series M, L, XL, II-L and II-XL
(Manual version 1.22)
Messenger XL
Is a trademarks
of
Ateïs International S.A.
Distributed by:
ATEÏS International S.A.
Chemin du Vallon, 26
CH-1030 Bussigny-près-Lausanne
SWITZERLAND
Phone: +41 21 881 2510
Fax: +41 21 881 2509
http//www.ateis-international.com
Messenger Operating Manual
TABLE OF CONTENTS
1. INTRODUCTION: ........................................................................................................................................ 4
2. GENERAL INFORMATION: ...................................................................................................................... 4
3. LIST OF SHIPPED ITEMS: ........................................................................................................................ 4
4. PRODUCTS: .................................................................................................................................................. 5
5. SYSTEM CONSIDERATIONS: .................................................................................................................. 5
6. PRODUCT VIEW: ........................................................................................................................................ 7
6.1
MOUNTING CONSIDERATIONS: .................................................................................................................... 8
7. M-CONTROL: ............................................................................................................................................... 9
7.1. U
NPACKING AND INSTALLATION ............................................................................................................. 10
8. USING THE SOFTWARE .......................................................................................................................... 10
8.1. M
INIMUM SYSTEM REQUIREMENTS ......................................................................................................... 10
8.2. G
ETTING STARTED .................................................................................................................................. 10
8.3. C
ONNECTING TO THE MESSENGER USING M-CONTROL ........................................................................... 11
8.3.1. Using the USB-485 interface: ........................................................................................................ 11
8.4. E
STABLISHING A CONNECTION BETWEEN PC AND MESSENGER: ............................................................. 11
9. THE PROGRAM TABS AND STANDARD SETTINGS: ....................................................................... 12
9.1. S
TATISTICS TAB: ..................................................................................................................................... 12
9.2. I
NPUT SETTINGS TAB:.............................................................................................................................. 13
9.2.1. Primary input: ................................................................................................................................ 13
9.2.2. Secondary input: ............................................................................................................................ 14
9.3. E.Q.
TAB: ................................................................................................................................................ 15
9.3.1. Filter selection: .............................................................................................................................. 15
9.3.2. Presets: ........................................................................................................................................... 16
9.4. G
LOBAL TAB: .......................................................................................................................................... 17
9.4.1. The UPLOAD of a LOBE (FIR-File) ............................................................................................. 18
9.4.2. Ambient noise following. ................................................................................................................ 19
9.4.3. VOX ................................................................................................................................................ 19
9.4.4. Ambient noise following and Vox both on. ..................................................................................... 19
9.4.5. Global amplifier gain: ................................................................................................................... 20
9.4.6. Design new Lobe filter. .................................................................................................................. 20
10. SYSTEM TAB: ......................................................................................................................................... 21
M
AIN SETTINGS: ................................................................................................................................................. 21
10.2. S
ETTINGS. ........................................................................................................................................... 22
11. SAVE YOUR DATA ................................................................................................................................ 23
12. MESSENGER LOBE ASSEMBLER SOFTWARE ............................................................................. 24
12.1. G
ENERAL INFORMATION ABOUT LOBE-ASSEMBLER: .......................................................................... 24
12.2. H
OW TO START WITH THE LOBE-ASSEMBLER SOFTWARE: ................................................................... 27
12.3. P
ERSONALISING OF YOUR PROJECT FILE: ............................................................................................. 27
12.4. V
ISUALISATION SCREEN: ..................................................................................................................... 28
12.5. S
PEAKER CHOICE: ............................................................................................................................... 29
12.6. L
OBE SHAPE SELECTION: ..................................................................................................................... 30
12.7. L
OBE PROPERTIES: .............................................................................................................................. 31
12.8. S
AVE AND EXPORTING FIR DATA: ....................................................................................................... 33
12.8.1. Save your project data: .................................................................................................................. 33
Page 2 of 38
12.8.2. Exporting a FIR-file or Lobe-file: .................................................................................................. 33
Messenger Operating Manual
13. EXAMPLES: ............................................................................................................................................ 34
13.1. P
ROJECT 1: .......................................................................................................................................... 34
13.2. P
ROJECT 2: .......................................................................................................................................... 35
13.3. P
ROJECT 3 ........................................................................................................................................... 36
13.4. P
ROJECT 4 ........................................................................................................................................... 37
Page 3 of 38
Messenger Operating Manual
1. Introduction:
This document describes the methods to be employed when installing and connecting
equipment associated with the Messenger XL digital controlled loudspeaker array, produced
by Ateïs International S.A.
This type of loudspeaker Array is equipped with onboard amplifiers, powersupply and signal
processing boards and needs extra precaution during installation and set-up of the unit.
The Messenger comes pre-programmed from the factory and is ready for immediate use. With
the concept of the Messenger we have focussed on an easy to install and to set-up unit which
does not lead to human errors and mistakes during the installation and set-up.
The Messenger can be programmed to adapt it for special applications where a different lobe-
shape is required. For that purpose you will need a USB-RS485 interface and the M-Control
communication protocol for Windows
®.
2. General information:
The Messenger XL has the unique quality that the acoustical centre can be moved over the
array to match with required mounting heights. This can be achieved because each driver is
separately powered and processed and therefore all variations between a Symmetrical and an
asymmetrical arrangement can be made by a simple push on a button. This separates the
Messenger XL from any other line-array speaker making it the most flexible and unique line
array with software controlled directivity pattern.
Lobes
:
The Symmetrical lobe has its acoustical-centre centred in the middle of the array. The
Asymmetrical lobe has its acoustical-centre centred at the bottom or at the top of the array.
Any other position of the acoustical-centre between the middle and the bottom/top of the array
fades the lobe-shape from a purely symmetrical shape to an asymmetrical shape.
Symmetrical lobes are mostly used to address balcony areas or is used for mounting heights
of 1.2m from the floor. It results in a sharply defined directive shape with vertical opening-
angles adjustable in steps from 40 down to 5 degrees. The lobe shape guarantees an equal
coverage even when seated very near to the source.
An asymmetrical lobe are used for typical mounting heights between 1.8 and 4m from the floor
and covers the groundsection. It results in a lobe that starts at 5m distance from the array at
ear-level and ends in a sharp lobe at 40m and further.(This depends on the type of array) The
Asymmetrical lobe has the ability to keep the sound deviation within 2 dB from 5 to 60m. Its
mounting height is NOT critical and therefore it is the most used system solution. The vertical-
opening angle can be adjusted in steps from 40 down to 5 degrees.
3. List of shipped items:
The following items are packed with the shipment in the carton of each Messenger:
Description: Pieces
Mounting brackets 2
230 VAC Powerplug, 3-pin. (Euro-stile plug) 1
Spare 24VDC fuse, 40 Amp. 1
Audio input/output connector, 3-pin. (Phoenix) 2
Data RS485 input/output connectors, 4-pin. (Phoenix) 3
Input / output contact interface, 8-pin. (Phoenix) 2
Factory test sheet 1
Page 4 of 38
Messenger Operating Manual
4. Products:
The Messenger XL series of products is series of digital controlled line-arrays with constant
directivity. The series contains the following products:
- Messenger M, a 12-way digital controlled steerable array, length 171 cm.
- Messenger L, a 18-way digital controlled steerable array, length 237 cm.
- Messenger XL, a 24 way digital controlled steerable array, length 304 cm.
- Messenger Two-L, a 36 way digital controlled steerable array, length 454 cm.
- Messenger Two-XL, a 48 way digital controlled steerable array, length 608 cm.
5. System considerations:
Mounting height of the Messenger XL is NOT critical. The Asymmetrical unit can be
positioned between 1.85 metre and 4 metre from the floor, measuring from floor level
to the centre of the first driver, acoustical mounting point, at the bottom of the array.
The symmetrical array is located at 1.2 metre from the floor measuring from floor level
to the centre of the first driver, acoustical mounting point, at the bottom of the array.
The acoustical centre of the Messenger can be moved over the array from bottom to
the middle and from the middle to the top in 9-stepsd. Special pre-constructed lobes
are available as well as lobes with variable opening angles.
The bottom of the array is indicated by the part that carries the service hatch behind
which the input connection board is located. The mains and the 24 VDC connectors
are located in this position. The battery for emergency purposes should be located as
close as possible to the array to avoid power loses over the cable. The built-in charger
is able to maintain the battery. It is NOT meant for quick or for normal charging!
The position of the acoustical centre of the Messenger can be chosen from a library of
lobes available from our download site at: www.ateis-international.com
The lobes can offer you system solutions in cases where there are special
requirements on mounting position or where there are height variations in the listening
plane.
When connecting the Messenger to the mains supply, be aware that the signal earth
of the Messenger is the same as the mains earth. It is recommended that the mains is
checked and connected to a proper ground. The mains should also be uninterrupted!
If this is not the case a backup power supply can be applied to maintain operation in
case of a power failures. Check the technical details in case of a battery back-up
source and its capacity.
The audio input to the Messenger should be according to one of the following
electrical standards:
Primary input:
Transformer balanced line level signal of 0 dBu 775 mV.
Level can be electronically adjusted
Maximum recommended distance: 300 metre.
Secondary input
: (Used for Ambient Noise Microphone or optional inputboard SD-1)
→♪ Un-balanced line level signal of 0 dBu or 6 dBu.
Level can be electronically adjusted
Audio output :
←♪ This output follows the signal input 1
Page 5 of 38
Level can be set in M-Control
Messenger Operating Manual
Optional input board for secondary input – SD-1:
→♪ Transformer balanced microphone level signal of 5 - 10 mV.
The Messenger is equipped with an RS485 data-network connection, which allows
remote system set-up and control of all parameters available through the M-Control
software for Windows®. Each addressable loop device gets a unique I.D. number for
quick FIR/Lobe downloads. I.D.-numbers are chosen between 1 and 32.
A two core communication link is used to connect an RS485 serial link to up to 32
Messengers using the DATA-RS485 input and slave-output.
NOTE: - An end-of-line resistor of 120 ohm should be applied to the last Messenger
connected in the data-ring.
The Ambient-Noise-Following option is supplied in the software and needs the
hardware module SD-1 and an ambient-noise microphone. The SD – 1 is equipped
with a pre-amplifier with phantom power and uses the secondary input of the
Messenger.
The ambient temperature for the Messenger XL should not exceed 40°C. If higher
temperatures are expected, precaution should be taken to avoid this by means of
installing extra forced ventilation within the Messenger. Alternatively a Messenger
XL/WP can be ordered which has the electronics externally installed in box. This unit
must be placed in a conditioned room.
2 potential-free OUTPUT contacts are provided to serve the following functions:
No. 1 Fatal fault
No. 2 General fault
2 Opto-coupler isolated inputs are provide for
No. 1 Priority Audio input 2 activated
No. 2 Lobe switch
Page 6 of 38
Messenger Operating Manual
6. Product view:
Typical: Messenger XL
Acoustical centre can be chosen from
symmetrical or any position in betwee
custome
asymmetric to
n to match with
r requirements.
Ref
acoustical m
Centre of th
erence point for
ounting height.
e bottom driver
Se
conne
rvice hatch with
ctor department
Bottom of the array
Page 7 of 38
Messenger Operating Manual
6.1. Mounting considerations:
Mounting instructions:
A: Acoustical centre When the acoustical centre is chosen in the lower range of the array,
an Asymmetrical lobe is generated. These are used in conjunction
with mounting heights between 1.8 and 4m from the floor and results
in a lobe that starts at 5m distance from the array at earlevel and ends
in a sharp lobe at 60m and further. The Asymmetrical lobe has the
ability to keep the sound deviation within 2 dB from 5 to 60m. Its
mounting height is NOT critical and therefore it is the most used
system solution. The vertical-opening angle is adjustable from 40
down to 5 degrees, with steering up to 30 degrees up and down.
The acoustical centre runs from A-symmetrical to Symmetrical, from
bottom to top in 9-steps.
H: Mounting height This height is measured between the floor and the bottom of the array
which starts at the bottom driver. (Small plate).
It is recommended to keep this height around 2mt.
D: Min. Distance This distance is measured from the front wall towards the first
listener’s position.
E: Effective range This distance is measured between the Messengers mounting
position and the last listener’s position.
Additional information:
Position: It is of vital importance that the Messenger is always placed in a rectangle
line with the listener’s plane. This ensures that reflected energy from the
back-wall stays in the acoustical centre and is not bounced into the ceiling
area where it might contribute artificial reverberation to the building
acoustics.
Opening angle: The vertical opening angle can be varied between 40 and 5 degrees.
Steering: Steering up to +/- 30 degrees.
Page 8 of 38
Messenger Operating Manual
7. M-Control:
All versions are controlled using the M-Control USB - 485 interface. This interface is available
from the pricelist. This interface is an electronic device that can only be used in conjunction
with the Messenger series of products and in conjunction with FIRMWARE VERSION V2.15
or higher. The device allows easy system configuration via a PC-link that is supported by
Windows
®
XP. (Other operating systems are not tested)
The software is a development of Ateïs International SA and is license free, but only available
for key-dealers and distributors. The M-Control interface combines access control and data-
link control and can be used as permanent interface or for configuration-use only. The
interface is delivered complete with a USB cable of approx. 1 meter and a CD with the
necessary driver software. The M-Control software and the Lobe-Assembler software are
also on this CD.
www.ateis-international.com
Page 9 of 38
USB
RS 485 connection
Messenger Operating Manual
7.1. Unpacking and installation
The RS485 box should contain the following items:
M-Control USB – 485 interface.
USB connection cable, length: 1 m.
Interface set-up manual.
CD with drivers for the interface, the M-Control program for setting up
the Messenger(s) and this user manual.
Before using the RS 485 interface, please check if all the given items are present. Secondly,
be sure that the FIRMWARE VERSION of your Messenger is reading V2.15 or higher. Lower
versions will not provide complete functionality of the M-Control Software.
The interface set-up manual can be found with the interface..
8. Using the software
The M-Control and Lobe-Assembler software packages are easy to use and provide full
access to all system features of the Messenger. All menu pages and sub-menus are displayed
and can be opened by clicking the appropriated icon. If you select a sub-menu, close current
before opening new menu or submenu. The cursor movement, selection of parameters and
parameter settings can be established with the use of the mouse and keys.
It is important to note that you store changes into the Messenger before terminating the
software program. After every power shutdown, or software reboot, the Messenger will start-
up in its last saved configuration.
8.1. Minimum system requirements
The minimum system requirements to run the M-Control and Lobe assembler software
properly should be:
PC-Pentium type with Windows
®
XP or higher
Free disk space of approximately 25 Mb
USB to RS 485 interface
8.2. Getting started
Insert the CD and click on “install M-Control and Lobe Assembler.
Install the drivers for the RS485 interface. (see the interface manual)
Latest version of M-control : Version 1.21
Latest version of the Lobe Assembler software : Version 1.10
Minimum firmware requirements of the Messenger : Version 2.32
Latest version of FIR-files (For Messenger V3) : Version V3.HAC
(Firmware information can be found on the inside sticker in the connection
bay of the Messenger).
After you have finished the installation you can run both programs.
Page 10 of 38
Messenger Operating Manual
8.3. Connecting to the Messenger using M-Control
8.3.1. Using the USB-485 interface:
The interface comes with a USB cable to connect the interface to the computer.
See the interface manual for installing the software for the interface and connecting
the Messenger(s) with the interface.
8.4.
Establishing a connection between PC and Messenger:
Once you have made the connection between your PC and the Messenger, via the
USB – 485 interface start M-Control.
Startup screen of M-Control.
Page 11 of 38
Select the COM port for communicating. Note that you can only select COM 1 till 4.
If all COM ports stay grey you have to set the USB-485 interface to a different COM
port. This has to be done in the Windows system settings menu.
Messenger Operating Manual
If you have a connection between the PC and the interface click on “scan for Messengers”
Note: The Messenger(s) must be powered-up for at least 20 seconds before the M-Control
program can detect them.
You will see the Messenger(s), which are present in the 485 loop.
Select the Messenger you want to control. In the bottom line of the screen you
can read the Messenger(s) you are connected to.
9. The program tabs and standard settings:
9.1. Statistics tab:
Here you can find the general information about the selected Messenger.
Page 12 of 38
Messenger Operating Manual
9.2. Input Settings tab:
If you are accessing a new Messenger (Factory Default) in the “input Settings” tab
the settings are as in the windows below.
9.2.1. Primary input:
INPUT SENSE Sets the input sensitivity of the primary input. By default this is
set to 0 dB.
LINE OUT Sets the output level to the next Messenger. By default this is
set to 0 dB.
VOLUME Sets the direct audio level of the primary input. By default this
is set to 0 dB.
NOISE GATE Is by default enabled and can be adapted to the situation by altering
the values in the boxes: Level, Hold and Soft fade (out).
PEAK LIMITER Is by default enabled and set at –3dB. It is our strong recommendation
that the peak-limiter stays enabled. It is for protection reasons. If high
SPL levels are required the limiter could be set to 0 dB. This will still
limits the audio at 0,1 dB before the AD converter starts clipping.
DELAY Maximum delay setting is 1000 ms.
Page 13 of 38
MUTE Audio MUTE mutes the primary input. It does not mute the audio path
from the audio-slave output.
Messenger Operating Manual
9.2.2. Secondary input:
VOLUME Sets the direct audio level of the secondary input. By default this is
set to 0 dB.
NOISE GATE Is by default enabled and can be adapted to the situation by altering
the values in the boxes: Level, Hold and Soft fade (out).
PEAK LIMITER Is by default enabled and set at –3dB. It is our strong recommendation
that the peak-limiter stays enabled. It is for protection reasons. If high
SPL levels are required the limiter could be set to 0 dB. This will still
limits the audio at 0,1 dB before the AD converter starts clipping.
DELAY Maximum delay setting is 1000 ms.
Page 14 of 38
MUTE Audio MUTE mutes the secondary input.
Messenger Operating Manual
9.3. E.Q. tab:
Changes made in the EQ settings are directly effecting the settings of the Messenger.
9.3.1. Filter selection:
The EQ-folder provides 7 free addressable filters. Every EQ has the following
pre-selectable filter-characteristics:
- All pass (Phase shifting)
- Low pass (high-cut)
- High Pass (low-cut)
- Low Shelving (Tone control)
- High Shelving (Tone control)
- Band pass
- Notch filter (Anti –feedback)
Page 15 of 38
- Peak filter (Room resonance’s)
Messenger Operating Manual
9.3.2. Presets:
Here you can select several factory-pre-set settings for the EQ.
Page 16 of 38
Note that the primary and secondary input have their own EQ.
Messenger Operating Manual
9.4. Global tab:
Page 17 of 38
Here you can upload Lobe files, set the amplifier gain, and several other things
described in this chapter.
There is the possibility to store two different Lobe files in the memory of the Messenger.
The selection of the Lobe is done with a contact closure. For further information see the
description of the input board.
Messenger Operating Manual
9.4.1.
The UPLOAD of a LOBE (FIR-File)
To upload a lobe, you first have to generate a FIR file from the Lobe-Assembler software.
(See section 4 of this manual). The file will carry the file extension: *.mfd (Export file from Lobe
Assembler)
Click on Upload (Lobe1 or Lobe2) and select the MDF (Messenger Fir Data)
you want to load in the Messenger.
For uploading the data into the Lobe1 section you get the following screen:
For uploading the data into the Lobe2 section you get the following screen:
Page 18 of 38
Click on send.
A running bar will show you the time remaining for the upload. During the upload the
unit will not pause its functioning, so an upload or lobe-change could be done during
a live performance. After loading the lobe click on activate.
It is advised to reset the Messenger after the upload of a new Lobe file.
The reset procedure is described in the System tab.
Messenger Operating Manual
9.4.2. Ambient noise following.
If Ambient noise following is activated the secondary input is turned into a measuring input.
This input accepts line signals. If a sensing microphone is connected we advise you to use
the SD 1 expansion input board. For all the details of the SD 1 expansion board we refer to
the appendix.
Max gain; determinates the maximum additional amplification.
Trigger level; is the point where the additional amplification starts.
The LED lights up when the trigger level is reached.
Correction; is the ratio between the level above trigger level and the increase in volume gain.
Example (correction is set at 30%):
if the Ambient noise level is 10dB above trigger level the volume gain will be 3 dB.
Speed; (slow – medium – fast) sets the reaction to changes the sensing
microphone is reregistering.
9.4.3. VOX
In this setting the secondary input can be used as alarm input.
If the audio level, on the secondary input, reaches a certain level
this signal overrides the primary input.
Trigger level; sets the point where the secondary input becomes active.
The LED lights up when the trigger level is reached.
Sustain; sets the hold time of the Vox in seconds.
9.4.4.
Ambient noise following and Vox both on.
Page 19 of 38
When those two functions are set on together the Ambient noise following function is set
with an extra feature. The Vox is now working as a threshold on the primary input.
This feature means that if the audio level on the primary input reaches the trigger level the
Ambient noise sensing is stalled at the correction value of that moment.
Messenger Operating Manual
9.4.5. Global amplifier gain:
This sets the gain of all the amplifiers. It can be set between –10dB and + 10dB.
Default setting is 0 dB.
For normal situations it is advised to keep the default setting. Only when a higher
SPL level is needed correct it upwards.
9.4.6. Design new Lobe filter.
Page 20 of 38
This starts the Messenger Lobe Assembler program.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

Optimus MESSENGERG2XL User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI