FMI LPA6000 Operating instructions

Type
Operating instructions
104795 01
Outlet: 3/8" FPT
Capacity: 160,000 Btu/Hour
WARNING: This low pressure regulator is designed
to regulate propane vapor only. This regulator meets all
the standards and safety codes for use on a horizontal
ASME tank or single vertical cylinder. The brass con-

left-hand threads. The vent must be pointing down
towards the ground when the regulator is properly
mounted (see Figure 1).

systems which allow liquid and debris to enter the
vapor system.

assembly be used immediately downstream of this regula-

long, marked “”, “”, -
”.
This regulator must be installed in compliance with federal, state,
local codes and laws, and in accordance with NFPA/ANS 58,
Storage and Handling of Liqueed Petroleum Gases.
Read and follow manufacturers’ instructions when installing this
regulator to a propane gas cylinder.

in a building, garage, or enclosed area.
The two stages of the model LPA6000 regulator reduce full cylin-
der pressure down to 11" water column outlet pressure nominally
at room temperature.
The gas appliance(s) served by this regulator must be supplied
with at least the minimum inlet pressure as specied by the manu-
facturer of the appliance(s). A qualied propane service person
should verify proper supply pressure at all appliances.
     
adjust, or service this propane gas regulator. If service
-
cian or dealer.

hear, see, or smell leaking propane gas, close all open
valves, and immediately get everyone away from the
-
tempt repairs.


        
close valve and have propane gas service person
make needed repairs. Also, check all appliance valves
and connections to make sure they do not leak before
lighting appliance.
X
X
X
X
X
X
X
X
LOW PRESSURE TWO-STAGE PROPANE/LP GAS
REGULATOR KIT MODEL LPA6000
For Use with Propane/LP Fueled Indoor Heating Appliances**
104795-01
Rev. C
02/07
Pressure
Relief
Valve
Cylinder Valve
Regulator Nut
or Connection
2-Stage Regulator
Cylinder
Regulator
Vent
Liquid Level
Indicator (Optional)
Figure 1 - Checking Gas Leaks
NOT A UPC
** Follow appliance manufacturer’s installation instructions.
Vent Must Point Down
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
The transportation, installation, and storage of propane cylinders
must be in compliance with federal, state, and local codes, and in
accordance with NFPA/ANS 58, Storage and Handling of Lique-
ed Petroleum Gases.
The design, materials, components, installation, repairs, and main-
tenance of the gas piping system connected to this regulator must
be in compliance with federal, state, and local codes and should
comply with National Fuel Gas Code ANS Z223.1, NFPA 54.
Protect this regulator from the elements by using the vented
protective cover included in this kit.


Your regulator is equipped with a vent because it is constantly “breath-
ing.” That is, the diaphragm of the regulator moves down and draws
air into the bonnet or adjustment spring housing. When the diaphragm
moves up, air is expelled through the vent. In the event that excess
pressure builds up in the lower housing or body of the regulator, a
relief mechanism vents it to the atmosphere. So, it is imperative to
check the vent frequently to be sure it is clean and free of water,
corrosion, or obstructions as clogging is the most common cause of
regulator malfunction. Great care has been taken in the manufacture
of your regulator and it has been thoroughly tested and U.L. listed.
However, even a small piece of dirt, corrosion, pipe dope or other
foreign matter which nds its way into the outlet can result in higher
than normal pressure (high lockup) and/or loss of fuel.
If the vent does become clogged it can easily be cleaned with a
toothbrush. In addition, your regulator should be checked periodically
by a competent propane serviceman to be sure it is properly adjusted
and in safe working condition. By following these simple precautions
your regulator will give you years of trouble free service.