LST BCE216-3LG is a sectional control panel extension that can be used to extend a BCnet216 fire detection control panel by two additional loops. It offers easy installation and can be integrated into an existing BCnet216 sectional control panel BC216-2 or BC216-3. The extension uses analogue ringbus technology, allowing for the administration of up to 198 physical address points in a maximum of 128 detector zones per loop. It supports both Apollo/Discovery and System Sensor/200 protocols for bi-directional data transfer.

LST BCE216-3LG is a sectional control panel extension that can be used to extend a BCnet216 fire detection control panel by two additional loops. It offers easy installation and can be integrated into an existing BCnet216 sectional control panel BC216-2 or BC216-3. The extension uses analogue ringbus technology, allowing for the administration of up to 198 physical address points in a maximum of 128 detector zones per loop. It supports both Apollo/Discovery and System Sensor/200 protocols for bi-directional data transfer.

© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
BCE216-3LG_DBL_LST_EN_0804.PDF • PAGE 1
ABuilding Safety. Building Security.
Control Panel Extension
Bcnet216: BCE216-3LG
BCnet sectional control panel with
two integrated loop interfaces
Extends a BCnet sectional control
panel BC216-2 or BC216-3 by two
loops
Analogue ringbus technology with
unshielded detector cabling
Easy installation, also possible later
on
Fire is a permanent threat to life and property. There-
fore, immediate response to a re is imperative. The
main objective of the re detection control panel Series
BC216 is to alarm and to react in time and, conse-
quently, save lives and protect property. For decades
LST have focused their aims to undertaking unrivaled
efforts in order to realize new innovations in the security
area. Research, development and production are loca-
ted within LST premises, thus guaranteeing fl exible and
reliable individual solutions.
Using a 32-bit multiprocessor system, the re detection
control panel Series BC216 ensures topmost effi ciency
and speed prerequisites for saving lives and minimi-
zing damage to property.
Description
The BCnet Sectional Control Panel/Extension BCE216-
3LG allows for the extension of a fi re detection control
panel BCnet216 by two ADM loops. The extension is in-
tegrated into the re detection control panel BCnet216
by installing it in a BCnet sectional control panel BC216-
2 or BC216-3 and connecting it to the GSSnet cabling
via the GSSnet interface on the extension.
The 24V supply of the BCnet Sectional Control Panel/Ex-
tension BCE216-3LG is powered from the BCnet sectio-
nal control panel in whose cabinet it has been installed;
it does not have a power supply or battery charger of
its own. The extension is designed as compact unit and
mounted on a pivoting sheet steel carrier.
The loop processing functions of the BCE216-3LG fully
correspond to the functions of a BCnet Sectional Con-
trol Panel BC216-2 equipped with two Loop Interfaces
LIF64-1.
The ADM loop principle offers intelligent analogue ring-
bus technology with bi-directional data transfer. Each
loop provides for the software-aided administration of
up to 198 physical address points in a maximum of 128
detector zones.
Easy parameterisation by means of PC software en-
ables you to optimally adapt the control panel to your
individual requirements.
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
BCE216-3LG_DBL_LST_EN_0804.PDF • PAGE 2
ABuilding Safety. Building Security.
Clear Concept
The BCnet Sectional Control Panel/Extension
BCE216-3LG extends a BCnet sectional control panel
BC216-2 or BC216-3, respectively, by two ADM loops.
It provides the following features:
Detectors and modules in ADM loop technology can
be connected to each Loop Interface LIF64-1. Depen-
ding on the parameterisation, either the Apollo/Disco-
very protocol or the System Sensor/200 protocol is
used to achieve bi-directional data transfer.
Logical combinations of detectors and detector zo-
nes for the activation of external controls and alar-
ming devices facilitate maximum exibility. Thus, no
additional expenses arise for external relays, logic
gates or timers. Thanks to the wide range of parame-
terisation possibilities, individual requirements even
under the most diffi cult ambient conditions can be
combined into a reasonable fi re protection strategy.
By integrating input and output modules on any positi-
on in the loop you can realize enablements or disable-
ments as well as control tasks in your system without
having to care for additional wires.
The free combination of detectors and modules into
logic sectors allows for the joint operation of defi ned
parts of the system even beyond the limits of loops
or sectional control panels.
The use of unshielded loop cables allows for cost-
saving and uncomplicated installation as well as for
the possibility of reusing the existing cabling.
At a possible breakdown of the central processing
unit which is integrated on the extension, the diver-
sifi ed redundancy concept ensures secure alarm re-
cognition.
The parameter data can be created by means of the
PC software PARSOFT and loaded into the control pa-
nel in a comfortable way. Thus, a quick and effi cient
transfer of the system confi guration into the control
panel is guaranteed.
AUTO setup facilitates parameterisation when the
control panel is commissioned or expanded and thus
helps to save time.
The BCnet Sectional Control Panel/Extension
BCE216-3LG is suitable for later installation in the wall
mount cabinet.
Owing to the compact design, a maximum of four loops
can be centralized in one single place. The required bat-
teries are accommodated in the wall mount cabinet or
in an external auxiliary case. Series BC216 thus stands
for modularity and easy expansion.
This product complies with all relevant standards of
EN 54 and is VdS-certifi ed. In addition, the product also
holds several country-specifi c approvals and certifi ca-
tes. LST‘s high quality level is secured by a permanent-
ly monitored quality management system certifi ed by
ISO 9001.
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
BCE216-3LG_DBL_LST_EN_0804.PDF • PAGE 3
ABuilding Safety. Building Security.
Permanent Connection
By means of a BCnet Sectional Control Panel/Extension
BCE216-3LG, a Fire Detection Control Panel BC216-2
or BC216-3, respectively, can be extended by two
loops. In one case, you thus have up to four loops at
your disposal. In addition, a variety of peripheral de-
vices can be connected to this device:
• Fire brigade key safe
• Fire brigade control unit
• Acoustic and optical signaling devices
• External protocol printer
• Remote display and operating panels
• Remote indication unit
• Actuations
• Electronic monitoring system
Transmitting device for the actuation of pagers via
ESPA protocol
Modules for remote parameterisation and remote
maintenance via computer newtork, modem or GSM
connection
Transmitter module for the transmission of messages
via SMS or e-mail
– and much more.
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
BCE216-3LG_DBL_LST_EN_0804.PDF • PAGE 4
ABuilding Safety. Building Security.
Specifi cations
Supply voltage 21 – 30 VDC
Current consumption at 24V 140mA (without detectors)
Idle loop current typ. 300µA per detector/module
Total loop current max. 300mA (at reduced line resistance)
Idle loop voltage typ. 26V (Apollo/Discovery) or
typ. 29V (System Sensor/200), respectively
Loop line resistance max. 50Ω per core
Number of ADM loops 2
Number of detector zones max. 128 per loop, max. 144 in total
Ambient temperature -5°C to +50°C
Dimensions W × H × D 248 × 222 × 28 (mm)
Weight approx. 675g
Part No. 214034
Order name BCnet Sectional Control Panel/Extension BCE216-3LG
The re detection control panel BCnet216 opens up ma-
nifold possibilities for the realization of specifi c requests
of re detection, especially in spacious buildings, high-
rise buildings or wide-stretched areas.
The decentralized security network that has been crea-
ted by BCnet216 offers increased security and reduces
the total expenses due to a much lower cabling volume.
The consistent ring-shaped cabling guarantees commu-
nication between the sectional control panels even in
the event of a line fault.
A sectional control panel of the BCnet216 is parame-
terised as main operating unit for the administration of
the GSSnet, all other members can be equipped with or
without a display and operating unit.
The system is designed modularly and can be gradually
expanded according to future demands. The maximum
size of a BCnet216 comprises 127 network members,
9700 detector zones, 9700 actuations, 999 alarming
devices, 99 transmitting devices as well as 199 logic
sectors. Different interfaces are available for the con-
nection of external information devices, e.g., a facility
management system or a remote maintenance sys-
tem.
Cabling of the detectors is required only between two
neighboring sectional control panels. This clear and
exible arrangement of the sectional control panel cre-
ates a powerful network. In this way, most economical
cabling and thus effi cient use of the installation expen-
ses is guaranteed. Larger distances between individual
sectional control panels can be bridged through the use
of optical fi ber modems or long distance modems.
The entire virtual control panel BCnet216 provides for
the monitoring in mid-sized and large systems, applying
the same technology and the same software tools as
with the single control panel BC216-1. This guarantees
a minimum of training and expansion costs as well as
expenses of the user and thus guarantees the optimal
use of resources during the usable life of the building.
BCnet sectional control panels are available in wall
mount cabinets, as 19“ compact version and in 19“
slide-in technology.
Distributed Intelligence in the GSSnet
If required, the BCnet216 can be easily expanded to
an extinguishing control panel LCnet216 according to
EN 12094-1. The panel can control up to 127 ooding
zones in a maximum of 127 extinguishing systems.
The function of the extinguishing control panel is fully in-
tegrated into the re detection control panel BCnet216,
a combined operation is therefore possible.
The LCnet216 is certifi ed to EN 54-2, EN 54-4,
EN 12094-1 and VdS as a pure extinguishing control
panel and as a combined re detection and extinguis-
hing control panel.
Optionally, the LCnet216 can be implemented with full
hardware redundancy.
Extinguishing Control System
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

LST BC216-3 User manual

Category
Networking
Type
User manual
This manual is also suitable for

LST BCE216-3LG is a sectional control panel extension that can be used to extend a BCnet216 fire detection control panel by two additional loops. It offers easy installation and can be integrated into an existing BCnet216 sectional control panel BC216-2 or BC216-3. The extension uses analogue ringbus technology, allowing for the administration of up to 198 physical address points in a maximum of 128 detector zones per loop. It supports both Apollo/Discovery and System Sensor/200 protocols for bi-directional data transfer.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI