Vermont Castings ODGSR42A Operating instructions

Category
Fireplaces
Type
Operating instructions

This manual is also suitable for

Vermont Castings ODGSR42A is a gas fireplace designed for outdoor use, providing warmth and ambiance to your patio or backyard. Its high temperatures make it suitable for use in both residential and commercial settings, and it can be installed in various locations, including screened porches, exterior chases, and even directly on combustible materials with a protective metal or wood panel. The ODGSR42A operates on either natural gas or liquid propane, and its gas inlet and manifold pressures can be adjusted to suit your specific gas supply.

Vermont Castings ODGSR42A is a gas fireplace designed for outdoor use, providing warmth and ambiance to your patio or backyard. Its high temperatures make it suitable for use in both residential and commercial settings, and it can be installed in various locations, including screened porches, exterior chases, and even directly on combustible materials with a protective metal or wood panel. The ODGSR42A operates on either natural gas or liquid propane, and its gas inlet and manifold pressures can be adjusted to suit your specific gas supply.

Outdoor Gas Fireplace
Models:
ODGSR36A, ODGSR42A
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.
WARNING: If the information in this
manual is not followed exactly, a re or
explosion may result causing property
damage, personal injury or loss of life.
—Do not store or use gasoline or other
ammable vapors and liquids in the
vicinity of this or any other appliance
—WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your
building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas
supplier, call the re department.
—Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
WARNING: Improperinstallation,
adjustment,alteration,serviceor
maintenancecancauseinjuryor
propertydamage. Read the installation,
operating and maintenance instructions
thoroughly before installing or servicing
thisequipment.
WARNING:
For Outdoor Use ONLY.
INSTALLER/CONSUMER
SAFETY INFORMATION
Homeowner'sInstallationand
OperatingManual
2000711410/13Rev.17
7114
ODGSR
cover
11/03
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
2
ODGSR Series Outdoor Gas Fireplace
20007114
Table of Contents
Thank you and Congratulations on your purchase of a Vermont Castings Group replace.
PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THE APPLIANCE
IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these
instructions may result in a possible re hazard and will void the warranty.
Installation & Operating Instructions..........................................................................................3
GeneralInformation.............................................................................................................3
FireplaceDimensions..........................................................................................................4
MoistureResistance............................................................................................................5
ScreenedPorchInstallation................................................................................................ 5
ClearancetoCombustibles.................................................................................................5
Mantels...............................................................................................................................5
Hearth ...............................................................................................................................5
MoistureResistance............................................................................................................6
Framing&Finishing............................................................................................................ 6
FinalFinishing.....................................................................................................................6
GasSpecications...............................................................................................................7
GasInlet&ManifoldPressures...........................................................................................7
HighElevations................................................................................................................... 7
ValveAccess.......................................................................................................................7
ExteriorChaseInstallation.................................................................................................. 8
GasLineInstallation............................................................................................................8
RemoteWallSwitch............................................................................................................9
Operating Instructions
LogInstallation..................................................................................................................10
LavaRock......................................................................................................................... 10
FirstFiring......................................................................................................................... 10
FlameAdjustment.............................................................................................................. 11
FlameCharacteristics........................................................................................................ 11
OptionalWeatherEnclosures............................................................................................12
OptionalStainlessSteelHood...........................................................................................12
Lighting&OperatingInstructions......................................................................................13
Troubleshooting................................................................................................................. 14
Maintenance.................................................................................................................................15
Replacement Parts......................................................................................................................16
Accessories..................................................................................................................................18
Warranty....................................................................................................................................... 19
Proposition 65 Warning:Fuelsusedingas,woodburn-
ingoroilredappliances,andtheproductsofcombus-
tionofsuchfuels,containchemicalsknowntotheState
of California to cause cancer, birth defects and other
reproductiveharm.
CaliforniaHealth&SafetyCodeSec.25249.6
IMPORTANT:
PLEASE READ THE FOLLOWING CAREFULLY
Removeanyplasticfromtrimpartsbeforeturningthe
replace“ON”.
Itisnormalforreplacesfabricatedofsteeltogiveoff
some expansion and/or contraction noises during the
startuporcooldowncycle.Similarnoisesarefoundwith
yourfurnaceheatexchangerorcarengine.
ItisnotunusualforyourVermontCastingsGroupFire-
placesgasreplacetogiveoffsomeodorthersttimeit
isburned.Thisisduetothecuringofthepaintandany
undetectedoilusedinthemanufacturingprocess.
Itisrecommendedthatyouburnyourreplaceforatleast
ten(10)continuoushoursthersttimeyouuseit.
3
ODGSR Series Outdoor Gas Fireplace
20007114
General Information
Thisgasapplianceshouldbeinstalledbyaqualiedin-
staller in accordance with local building codes and with
current CSA-B149.1 Installation codes for Gas Burning
AppliancesandEquipment.
FORU.S.AInstallationsfollowlocalcodesand/orthecur-
rentNational Fuel Gas Code. ANSI Z223.1/NFPA 54.
In the Commonwealth of Massachusetts, all gas ttings
andinstallationofthisheatershallonlybedonebyali-
censedgastterorlicensedplumber.
FOR SAFE INSTALLATION AND OPERATION PLEASE
NOTE THE FOLLOWING:
1. This appliance gives off high temperatures and should be
locatedoutofhightrafcareasandawayfromfurniture.
2. Childrenandadultsshouldbealertedtothehazardsofthe
highsurfacetemperaturesofthisapplianceandshouldstay
awaytoavoidburnsorignitionofclothing.
3. Childrenshouldbecarefullysupervisedwhentheyareinthe
sameroomasyourappliance.
4. Undernocircumstancesshouldthisappliancebemodied.
Partshavingtoberemovedforservicingshouldbereplaced
priortooperatingthisapplianceagain.
5. Installationandanyrepairstothisapplianceshouldbecar-
riedoutbyaqualiedserviceperson.Aprofessionalservice
personshouldbecontactedtoinspectthisapplianceannually.
Makeitapracticetohaveallofyourgasapplianceschecked
annually. More frequent cleaning may be required due to
excesslintanddustfromcarpeting,beddingmaterial,etc.
6. Controlcompartments,burnersandairpassagesinthisap-
plianceshouldbekeptcleanandfreeofdustandlint.Make
surethatthegasvalveandpilotlightareturnedoffbefore
youattempttocleanthisunit.
7. Keepthearea around your appliance clear ofcombustible
materials,gasolineand otherammablevaporandliquids.
Thisapplianceshouldnotbeusedasadryingrackforcloth-
ing,norshouldChristmasstockingsordecorationsbehung
intheareaofit.
8. Undernocircumstancesshouldanysolidfuels(wood,coal,
paperorcardboardetc.)beusedinthisappliance.
9. Theowofcombustionandventilationairmustnotbeob-
structedinanyway.
10.Whethertheapplianceisinstalleddirectlyoncarpeting,vinyl
tileoranycombustiblematerialotherthanwood,thisappliance
mustbeinstalledonametalorwoodpanelextendingthefull
widthanddepthoftheappliance.
11.Thisappliancerequiresadequateventilationandcombustion
airtooperateproperly.
12.Donotusethisapplianceifanyparthasbeenunderwater.
Immediatelycallaqualiedservicetechniciantoinspectthe
applianceandtoreplaceanypartofthecontrolsystemorgas
controlthathasbeenunderwater.
13. Inspect the burner before each use of the appliance. The
burner must be replaced prior to operation if there is evi-
dencetheburnerisdamaged.Useonlyburnerspeciedby
manufacturer.
LP-cylinderenclosures,ifprovidedbytheconsumermustconform
tothedesignparametersasdetailedbelow.
Enclosures for LP-Gas Supply Systems
Enclosures for LP-gas supply cylinders shall be ventilated by
openingsatthelevelofthecylindervalveandatoorlevel.The
effectivenessoftheopening(s)forpurposesofventilationshall
bedeterminedwiththeLP-gassupplycylinder(s)inplace.This
shallbeaccomplishedbyoneofthefollowing:
a. Onesideoftheenclosureshallbecompletelyopen;or
b. Foranenclosurehavingfoursides,atopandabottom:
1. Atleasttwoventilationopeningsatcylindervalvelevelshall
beprovidedinthesidewall,equallysized,spacedat180
degrees(3.14rad),andunobstructed.Eachopeningshall
haveatotalfreeareaofnotlessthan1/2squareinchper
pound(3.2sq.cm/kg)ofstoredfuelcapacityandnotless
thanatotalfreeareaof10squareinches(64.5sq.cm).
2. Ventilationopening(s)shallbeprovidedatoorleveland
shallhaveatotalfreeareaofnotlessthan1/2squareinch
perpound(3.2sq.cm/kg)ofstoredfuelcapacityandnot
lessthanatotalfreeareaof10squareinches(64.5sq.cm).
Ifventilationopeningsatoorlevelareinasideall,there
shallbeatleasttwoopenings.Thebottomoftheopenings
shallbeatoorlevelandtheupperedgenomorethan5
inches(127mm)abovetheoor.Theopenings shallbe
equallysized,spacedat180degrees(3.14rad)andun-
obstructed.
3. Everyopeningshallhaveminimumdimensionssoasto
permittheentranceofa1/8inch(3.2mm)diameterrod.
Cylindervalvesshallbereadilyaccessibleforhandoperation.
Adoorontheenclosuretogainaccesstothecylindervalvesis
acceptable,provideditisnon-lockingandcanbeopenedwithout
theuseoftools.
Thereshallbeaminimumclearanceof2inches(51mm)be-
tweenthelowersurfaceoftheooroftheLP-gassupplycylinder
enclosureandtheground.
Thedesign oftheapplianceshallbesuchthat(1) theLP-gas
supplycylinder(s)canbeconnected,disconnectedandthecon-
nectionsinspectedandtestedoutsidethecylinderenclosure;and
(2)thoseconnectionswhichcouldbedisturbedwheninstalling
the cylinder(s) in the enclosure can be leak tested inside the
enclosure.
Description
TheODGSRSeriesareradiantreplaces.Donotburnwoodor
othermaterialsintheseappliances.Eachmodelisavailablewith
standingpilotforusewithNaturalorPropanegasunits.
Reporttoyourdealeranypartsdamagedinshipment.
Adequate combustion and ventilation air must be provided.
Theowof combustionandventilationairMUSTNOTbeob-
structed.
Provide adequate clearances around the air opening into the
combustionchamber;andadequateaccessibilityclearancefor
servicingandproperoperation.NEVERobstructthefrontopen-
ingoftheappliance.
This replace is not designed to be water tight. There-
fore, when installing this unit against an exterior wall,
the wall must be nished before setting unit in place.
4
ODGSR Series Outdoor Gas Fireplace
20007114
42"
(1067mm)
46"
(1168mm)
396"
(1007mm)
6
" (16mm)
50" (1270mm)
50" (1270mm)
56O" (13mm)
56O"
56O
" (1791mm)
"
(610mm)
436M"
(1111mm)
56O"
(191mm)
56O"
(165mm)
56O"
(191mm)
Rough
Opening
Height
6"
(16mm)
22"
(559mm)
56O"
(572mm)
56M"
(667mm)
Recessed
Nailing
Flange
Rough Opening Width 47"
Rough
Opening
Depth
3"
(76mm)
3556M" (895mm)
(1194mm)
7114
ODUVSR42A
specs
11/03
1456M"
(362mm)
36M"
(95mm)
Low Voltage
Wire Access
Gas Line Access
1456M"
(362mm)
Low Voltage
Wire
Access
Fireplace Dimensions
Fig. 2 ODGSR42Aspecicationandframingdimensions.
36"
(914mm)
40"
(1016mm)
396"
(1007mm)
6
" (16mm)
56O" (13mm)
56O"
6" (822mm)
"
(622mm)
436M"
(1111mm)
856M"
(210mm)
56O"
(165mm)
56O"
(191mm)
Gas Line Access
Rough
Opening
Height
6"
(16mm)
22"
(559mm)
56O"
(572mm)
" (559mm)
Recessed
Nailing
Flange
Rough Opening Width 41"
Rough
Opening
Depth
36M"
(95mm)
(1041mm)
3(6"
(98mm)
7114
ODUVSR36A
Specs
11/03
68
56O
" (1740mm)
4856O" (1232mm)
4856O" (1232mm)
1456M"
(362mm)
36M"
(95mm)
Low Voltage
Wire Access
1456M"
(362mm)
Low Voltage
Wire
Access
Fig. 1 ODGSR36Aspecicationandframingdimensions.
Fireplace Dimensions
5
ODGSR Series Outdoor Gas Fireplace
20007114
Moisture Resistance
Thisoutdoorreplacewillshedmoderateamountsofwa-
ter, but is not waterproof. Water and condensing water
vapormayenterthechaseundercertainconditions.
Thereplace will not perform as an exteriorwall. Mois-
turepenetrationmustbeconsideredforconstructionthat
placesthereplaceinstructurewallsoronmoisturesen-
sitivesurfaces.
When installed on exterior walls: Vermont Castings
Group recommends the replace chase be constructed
outsidethestructure'sweatherenvelope.Wheretheplat-
formmeetsthewall,useaashingdetailsimilartothat
required for attached decks. Chase platforms, including
hearthsshouldslopeawayfromthestructureat1/4inper
foot.Thereplacecanbeshimmedlevel.
When installed on surfaces where water may collect or
causedamage:VermontCastingsGrouprecommendsa
slopeof1/8into1/4inperfoottowardsthedrainportsug-
gested.Thereplacecanbeshimmedlevel.
Hearthsshouldslopeawayfromthefrontofthereplace
andchaseat1/8into1/4inperfoot.Metalsafetystrips
mustbeontopofanycombustiblehearthmaterialsused
formoisturemanagement.
Clearance to Combustibles
Appliances
Top..........................................................0”(0mm)
Bottom.....................................................0”(0mm)
Side.........................................................0”(0mm)
Back........................................................0”(0mm)
PerpendicularSidewall...........................0”(0mm)
Topofunittoceiling..........................36”(914mm)
Frontofunittocombustibles.............36”(914mm)
Screened Porch Installation
TheODGSRmaybeinstalledsafelyandisdesigncerti-
edbyCSAtobeinstalledinascreenedporchwiththese
guidelines:
Minimumporcharea..............................96sq.feet(9sqm)
Minimumceilingheight.................................... 92"(234cm)
Minimumoftwo(2)wallsmustbescreened
Minimumtopofscreenheight,sidewalls........6'6"(198cm)
Minimumscreenarea............................64sq.feet(6sqm)
Mantels
WARNING:A4"hoodmustbeusedifamantel
istobeinstalled.
Theheightthatacombustiblemantelisttedabovethe
replaceisdependentonthedepthofthemantel.Thisalso
appliestothedistancebetweenthemantelleg(iftted)
andthereplace.
ForthecorrectmountingheightandwidthsrefertoFigures
3aand3b
Noncombustiblemantelsandlegsmaybeinstalledatany
heightandwidtharoundtheappliance.
When using paint or lacquer to finish the
mantel, such paint or lacquer must be heat
resistant to prevent discoloration.
A
B
Y
Z
Fireplace
CFM146
DV Mantel Chart
7/5/01 sta
Ref. Mantel Ref. Mantel From Top
Shelf Depth of Comb. Chamber
Y 8" (203mm) A 28" (711mm)
Z 1¹⁄₂"(38mm) B 26" (660mm)
CFM146
TopofCombustion
Chamber
Fig. 3aMantelclearances.
Side View
Standoff
Maintainminimum
3/4"(19mm)
clearancetocom-
bustible.
Hearth
Ahearthisnotmandatorybutisrecommendedforaesthetic
purposes.Werecommendanoncombustiblehearth.
6
ODGSR Series Outdoor Gas Fireplace
20007114
Framing and Finishing
Check appliance to make sure it is levelled
and properly positioned.
Theapplianceshouldonlybemountedonthefollowing
surfaces:
Aatcombustible(burnable)surface.
Araisedwoodenplatform.
Aconcreteblockorothersolidobjectplacedbeneath
eachofthefourcornersoftheappliance.
Tomounttheappliance:
1.Chooseunitlocation.
2.Four(4)nailingangesaresuppliedwiththereplace
(found on the replace hearth). Tolevel the box and
secure it rmly in place, remove the nailing anges
fromthehearthandinstallatthesidesofthereplace
asshowninFigure4.
Finishing
CAUTION: All joints between the nished wall
and the appliance surround (top and sides)
may be sealed only with non-combustible
material. Only noncombustible material can
be applied as facing to the appliance surround
(the black painted face).
Finishthewallwiththematerialofyourchoice.Referto
Figures3aand3bforspecicclearanceswheninstalling
acombustiblemantelorothercombustibleprojection.
FP549
Fig. 4 Adjustabledrywallstrip(nailingange).
FP549
9/29/97
BR/BC
NailTop
Standoffs
NailSide-
Nailing
Flanges
J
F
G
H
I
Mantel
Leg
CFM164a
Mantel Leg Chart
06/22/01 sta
CFM170
DV Builder Front
View
O
N
M
L
K
Ref. Mantel Ref. Mantel Leg From
Leg Depth of Comb. Opening
F 14" (356mm) K 14" (356mm)
G 12" (305mm) L 12" (305mm)
H 10" (254mm) M 10" (254mm)
I 8" (203mm) N 8" (203mm)
J 1¹⁄₂" (38mm) O 1¹⁄₂" (38mm)
Black
Surround
Face
CFM164
CFM170
Fig. 3bCombustiblemantellegminimuminstallation.
Sideof
CombustionChamber
Moisture Resistance
Thisoutdoorreplacewillshedmoderateamountsofwa-
ter, but is not waterproof. Water and condensing water
vapormayenterthechaseundercertainconditions.
Thereplace willnot perform as an exterior wall. Mois-
turepenetrationmustbeconsideredforconstructionthat
placesthereplaceinstructurewallsoronmoisturesen-
sitivesurfaces.
When installed on exterior walls: Vermont Castings
Group recommends the replace chase be constructed
outsidethestructure'sweatherenvelope.Wheretheplat-
formmeetsthewall,useaashingdetailsimilartothat
required for attached decks. Chase platforms, including
hearthsshouldslopeawayfromthestructureat1/4inper
foot.Thereplacecanbeshimmedlevel.
When installed on surfaces where water may collect or
causedamage:VermontCastingsGrouprecommendsa
slopeof1/8into1/4inperfoottowardsthedrainportsug-
gested.Thereplacecanbeshimmedlevel.
Hearthsshouldslopeawayfromthefrontofthereplace
andchaseat1/8into1/4inperfoot.Metalsafetystrips
mustbeontopofanycombustiblehearthmaterialsused
formoisturemanagement.
7
ODGSR Series Outdoor Gas Fireplace
20007114
Gas Inlet & Manifold Pressures
Natural LP
MinimumInletPressure 5.5”w.c. 11.0”w.c.
MaximumInletPressure 14.0”w.c. 14.0”w.c.
ManifoldPressure 3.5”w.c. 10.0”w.c.
Gas Specication
Max. Min.
Model Fuel Gas Control Input Input
ODGSR36ARN Nat. MillivoltHi/Lo 60,000 42,600
ODGSR36ARP Prop. MillivoltHi/Lo 60,000 44,000
ODGSR42ARN Nat. MillivoltHi/Lo 60,000 42,600
ODGSR42ARP Prop. MillivoltHi/Lo 60,000 44,000
High Elevations
Input ratings are shown in BTU per hour and are
certied without deration from elevations up to 4,500
feet (1,370 m) above sea level.
Nuisance outages may occur at altitudes above 4,500
feet (1,370 m) if dirt, dust, lint and/or cobwebs are
allowed to accumulate on burner and/or ODS pilot.
Monthly inspection and cleaning is recommended
for altitudes above 4,500 feet (1,370 m)
For elevations above 4,500 feet (1,370 m), installa-
tions must be in accordance with the current ANSI
Z223.1/NFPA 54 and/or local codes having jurisdic-
tion.
Valve Access
Valveaccesscanbeaccomplishedinoneoftwoways:
1. Removethefrontpaneljustbelowthefrontofthehearth
pan.This is accomplished by lifting on the panel.To
replacethevalveaccesspanellineupthetwopinswith
theholesinthesurroundbottomandpushthepanel
overthefrontofthehearthpan.(Fig.5)
2. LiftthebrickwiththeVermontCastingsGrouplogoon
it.(Fig.6)
ODGSR36A / ODGSR42A
Certied to
ANSI Z21.97
Outdoor Decorative Gas Appliances
CGA CR97-003
Outdoor Gas Fireplaces
FP1414
ODUVSR
valve access
11/24/03 djt
FP1414
Fig. 5Valveaccess.
FP1415
lift brick access
11/24/03 djt
VermontCast-
ingsGroup
LogoBrick
Fig. 6Liftbrickwithlogoonittoaccessvalve.
FP1415
NOTE:Wheninstallationis
onahard,atsurface(such
asconcrete),thesurface
mustbesloped1/4"perfoot
awayfromanystructure.
Blocking
Hard,FlatSurface
(i.e.concrete)
FP1642a
Fig. 7Exteriorchaseinstallation.
8
ODGSR Series Outdoor Gas Fireplace
20007114
FP1416
ODUVSR
part id
11/24/03 djt
Nailing
Flange
ValveAccessPanel
Firebox
Grate
Screen
Standoff
Surround
Gas
LineAc-
cess
FP1416
Fig. 8Partsidentication.
*Donotinstall
headeruntilunit
isinplace.
FP1416
ODUVSR
part id
11/24/03 djt
NailingFlange
ValveAccessPanel
Firebox
Grate
Screen
Standoff
Surround
Gas
Line
Access
*Donotinstall
headeruntilunit
isinplace.
Interiorsidesofanexteriorchase
shouldbeweatherproof
FP1644
Fig. 9Exteriorchaseinstallation.
Gas Line Installation
Thisappliancemustbeisolatedfromthegassupplypiping
systembyclosingitsindividualmanualshutoffvalveduring
anypressureequaltoorlessthan1/2psig(3.45kPa).
Theapplianceanditsindividualshutoffvalvemustbedis-
connectedfromthegassupplypipingsystemduringany
pressuretestingofthatsystemattestpressuresinexcess
of1/2psig(3.45kPa).
Ifgaspipingfromthesourcetotheappliancelocationhas
notbeenaccomplished,installtherequiredpipe.Consult
localplumbingcodetoassureproperpipesize.
Thegaspipelinecanbebroughtinthroughtherightsideof
theappliance.Aknockoutisprovidedtoallowforthegas
pipeinstallationandtestingofanygasconnection.
NOTE: The gas line connection can be made with 3/8"
coppertubingapprovedforpropaneornaturalgas,1/2"
rigidpipeoranapprovedexconnector,thenreducedto
3/8"totheappliance.Becausesomemunicipalitieshave
someadditionallocalcodes,it isalwaysbesttoconsult
yourlocalauthority.
U.S.:ConsultthecurrentNationalFuelGasCode,ANSI
Z223.1/NFPA54.
Canada:CSA-B149.1installationcode.
Testforleaks.Usea50/50solutionofliquidsoapandwater
totestforleaksatgasttingsandjoints.Applywater/soap
solutionwithbrushonly-donotoverapply. NEVER test
withanopename.
Thegascontrolisequipped withacapturedscrewtype
pressuretestpoint,thereforeitisnotnecessarytoprovide
a1/8"testpointupstreamofthecontrol.
Whenusingcopperorexconnectoruseonlyapproved
ttings.Always provide a unionsothatgaslinecanbe
easilydisconnectedforburnerorfanservicing.Seegas
specicationforpressuredetailsandratings.NOTE:Ifex
connectorisused,itmustbekeptinsideoftheappliance.
(Fig.10)
FP598
Fig. 10 Typicalgassupplyinstallation.
GF598
nvb GAS SUPPLY INSTALL
12/4/97
1/2"GasSupply
1/2"x3/8"Shut-offValve
3/8"Nipple
3/8"Union
3/8"Nipple
9
ODGSR Series Outdoor Gas Fireplace
20007114
Remote Wall Switch
NOTE:Useanapprovedoutdoorswitch.
1.Threadwirethroughthelowvoltagewireaccesshole
locatedoneithersideofunit.Donotcutwireorinsula-
tiononmetaledges.Ensurethatwireisprotected.Run
theotherendtoaconvenientlylocatedwallreceptacle
box.
2.Attachwiretoswitchandinstallswitchintoreceptacle
box.Attachcoverplatetoswitch.
3.Connectwiringtogasvalve.RefertoFigure11.
CAUTION: Do not wire millivolt remote wall
switch for gas appliance to a 120v power
supply.
For lighting instructions, refer to Page 12.
NOTE: If glass doors are installed, the unit must be
operated with the doors fully open. (Fig. 12) If the doors
are not fully open, the thermodisk will automatically
turn the unit off.
CAUTION: After the unit cools, the burner will
automatically come on.
MD706-7
Glass Door Position
1/20/99
OPEN
Correct
Wrong
MD706-7
Fig. 12Correctdoorpositionduringoperation.
Pilot
Thermodisk
On/Off
Switch
Valve
HV105
Fig. 11 Remoteswitchwiring.
HV105
Generic Gas Valve
9/22/99 djt
TPTH
TH
TP
10
ODGSR Series Outdoor Gas Fireplace
20007114
Operating Instructions
Log Installation
1.Removelogsfromthepackaging.
As with all plastic, these bags
are not toys and should always
be kept away from children and
infants.
2. Place left rear log on rear log support.
Ensure that log is rmly positioned and
thereisnoside-to-sidemovement.(Figs.
13&14)
3.CarefullyplaceEmberLogbetweengrate
andburner.(Figs.13&14)
4. Place the front of right rear log on the
burnerandthebackofthelogontherear
logsupport.
5.Placethetoplogsontothelocatornotches.
Ensure the logs are secure. (Fig. 13 &
14)
First Firing
Uponcompletingthegaslineconnection,asmall
amountofairwillbetrappedintheline.Whenrst
lighting the unit with pilot light, it will take a few
minutestopurgethetrappedair.Oncepurgingis
complete,thepilotandburnerwilllightandoperate
asindicatedintheinstructionmanual.Subsequent
lightingsoftheappliancewillnotrequirepurging.
Whenlitforthersttime,theappliancewillemita
slightodorforanhourortwo.Thisisduetopaint
andlubricantsusedinthemanufacturingprocess.
Aftereachlighting,vapormaycondenseandfog
theglass;thismoisturedisappearsinafewminutes
ofburning.
LG317
UVODSR36
logs
11/24/03 djt
RightCross
Log
LeftCross
Log
LeftRear
Log
RightRear
Log
Ember
Log
LG317
Fig. 13ODGSR36logplacement.
LG318
ODUVSR42
log set
11/24/03 djt
LeftRear
Log
LeftCross
Log
MiddleCrossLog
RightCross
Log
RightRear
Log
LogLeft
Ember
Grate
Fig. 14ODGSR42Alogplacement.
LG318
LogRight
Ember
11
ODGSR Series Outdoor Gas Fireplace
20007114
LG320
ODUVSR42
log flames
11/24/03 djt
LG320
Fig. 18ODGSR42Aameappearance.
Fig. 16Properpilotameheight.
FP581
3/8"-1/2"
FP581
NVB-PILOTS
12/4/97
ELECTRONIC
IGNITION
NOVA SIT Pilot
LG319
ODUVSR36
log flames
11/24/03 djt
RedGlow
LG319
Fig. 17 ODGSR36Aameappearance.
Flame Adjustment
ForunitsequippedwithHi/Lovalves,ameadjustmentis
accomplishedbyrotatingtheHi/Loadjustmentknoblocated
nearthecenterofthegascontrol.
L
O
H
I
Turn
counterclockwise
to increase
flame height
Turn clockwise
to lower
flame height
FP390
FLAME ADJUSTMENT KNOB
11/21/96
Fig. 15FlameadjustmentknobforSIT820valve.
Flame Characteristics
Itisimportanttoperiodicallyperformavisualcheckofthe
pilotandtheburnerames.Comparethemtotheillustra-
tionsbelow(Figs.16,17,18).Ifanyoftheamesappear
abnormalcallaserviceperson.
12
ODGSR Series Outdoor Gas Fireplace
20007114
Optional Weather Enclosure
Anoptionalweatherenclosureisavailabletoprotectthe
burnerwhennotinuse.
CAUTION:Donotusetheweatherenclosureif
theunithasglassdoorsinstalled.
Installation Instructions
1. TurntheunitOFFandallowtocool.
2. Grabtheweatherenclosurebythehandle(s).
3. Slidethetopoftheweatherenclosureupbetweenthe
backofthesurroundtopandthescreenrail.(Fig.19)
4. Pushthebottomoftheweatherenclosureintothere-
boxjustenoughtoclearthevalveaccesscoverandset
down.(Fig.20)
KT457
place we top
4/1/04 djt
KT457
Fig. 19Placetopofweatherenclosurebetweensurroundtop
andscreenrail.
SurroundTop
WeatherEnclosure
ScreenRail
KT458
place we bottom
4/1/04 djt
Screen
HearthBrick
ValveAccessCover
KT458
Fig. 20Pushbottomofweatherenclosureintorebox.
Optional Stainless Steel Hood
Anoptionalstainlesssteelhoodisavailableforboththe
ODGSR36AandODGSR42A.
NOTE: The stainless steel hood may NOT be
used when the optional glass doors are in-
stalled.
Installation Instructions:
1. Turntheunitoffandallowtocool.
2. Placethehoodsothe2B⁄,"(67mm)slotclearsthesen-
sor plate located under the replace opening onthe
topleftside.(Fig.21)
3. Securethehoodtotheunitusingthethree(3)slotsin
thehoodandthepilotholesintheunitwiththestain-
lesssteelsheetmetalscrewsprovided.(Fig.21)
4. Align the sides of thehood sothe pilotholes onthe
rightandleftsidesoftheunitareexposedthroughthe
slots on the ends of the hood. Secure using the re-
mainingstainlesssteelsheetmetalscrews.(Fig.21)
&0
/$'32HOOD

Stainless
SteelHood
Stainless
SteelSheet
MetalScrews
(5)
SensorPlateSlot
FP1635
Fig. 21Securestainlesssteelhoodwithve(5)sheetmetal
screws.
13
ODGSR Series Outdoor Gas Fireplace
20007114
3. Opencontrolaccesspanel.
4. Pushingascontrolknobslightlyandturnclock-
wise to"OFF".Donotforce.
5. Closecontrolaccesspanel.
1. STOP!Readthesafetyinformationabove.
2. TurnOFFallelectricalpowertothereplace.
3. ForMN/MP/TN/TPappliancesONLY,goontoStep
4.ForRN/RPappliancesturntheOn/Offswitchto
OFF”positionorsetthermostattolowestlevel.
4. Opencontrolaccesspanel.
5. Pushingascontrolknobslightlyandturnclock-
wise to"OFF".
6. Waitve(5)minutestoclearoutanygas.Then
Immediatelylightthepilotbyrepeatedlydepress-
ing the piezo spark ignitor until a ameappears.
Continuetoholdthecontrolknobinforaboutone
(1)minuteafterthepilotislit.Releaseknobandit
willpopbackup.Pilotshouldremainlit.Ifitgoes
out,repeatsteps5through8.
• Ifknobdoesnotpopupwhenreleased,stop
andimmediatelycallyourservicetechnicianorgas
FOR YOUR SAFETY READ BEFORE LIGHTING
• Ifyoucannotreachyourgassupplier,callthe
FireDepartment
C.Useonlyyourhandtopushinorturnthegascontrol
knob.Neverusetools.Iftheknobwillnotpushinor
turnbyhand,donottrytorepairit,callaqualied
servicetechnician.Applyingforceoranyattempted
repairmayresultinareorexplosion.
D.Donotusethisreplaceifanyparthasbeenunder
water.Immediatelycallaqualiedservicetechnician
toinspecttheheaterandtoreplaceanypartofthe
controlsystemandanygascontrolwhichhasbeen
underwater.
A. Thisheaterhasapilotwhichmustbelitmanu-
ally. When lighting the pilot follow these
instructionsexactly.
B. BEFORELIGHTINGsmellallaroundtheheater
areaforgas.Besuretosmellnexttotheoor
becausesome gasis heavierthan airand will
settleontheoor.
WHAT TO DO IF YOU SMELL GAS
• Donottrytolightanyreplace
• Donottouchanyelectricswitch
• Donotuseanyphoneinyourbuilding
• Immediatelycallyourgassupplierfromaneigh-
bor'sphone.Followthegassupplier'sinstruc-
tions.
To Turn Off Gas to Heater
Lighting and Operating Instructions
1. TurntheOn/Offswitchto"OFF"positionorset
thethermostattolowestsetting.
2. Turn off all electric power to the replace if
serviceistobeperformed.
Lighting Instructions
smellforgas,includingneartheoor.Ifyousmell
gas,STOP!Follow"B"inthesafetyinformation
above.Ifyoudonotsmellgas,gotothenext
step.
7. Removeglassdoorbeforelightingpilot.(See
GlassFrameRemovalsection).
8. Visiblylocatepilotbythemainburner.
9. Turnknobongascontrolcounterclockwise
to"PILOT".
10. Push the control knob all the way in and hold.
supplier.
• Ifafterseveraltries,thepilotwillnotstaylit,
turn the gas control knob to "OFF" and call your
servicetechnicianorgassupplier.
11.Replaceglassdoor.
12.Turngascontrolknobto“ON”position.
13.ForRN/RPappliancesturntheOn/OffswitchtoON”
positionorsetthermostattodesiredsetting.
14.Turnonallelectricalpowertothereplace.
WARNING:If you do not follow these instructions exactly, a re or explosion
may result causing property damage, personal injury or loss of life.
Euro SIT SIT NOVA
Honeywell
PILOT
ON
OFF
ON
P
I
L
O
T
O
F
F
O
F
F
FP1067
lighting instruction
knobs
3/9/01 djt
5
4
3
2
1
O
F
F
P
i
l
o
t
3/8" - 1/2"
FP1068
Lighting instructions
Pilots
14
ODGSR Series Outdoor Gas Fireplace
20007114
Troubleshooting
FP396
Gas Supply On
Supply Line Hooked up
Shutoff Valve Open
NO
NO
NO
NO
Lockout has engaged. Wait 60
seconds and try again.
Piezo not tight enough for good
ground.
For spark at electrode while
depressing Piezo (Red Button)
1/8" gap to pilot hood needed.
All wiring connections
Replace Piezo Ignitor
Thermodisk
For Air in the lines
Thermopile needs a minimum
325mV. Adjust pilot flame height.
All wiring connections
Replace Thermopile
Thermocouple needs a minimum
of 14mV.
Defective valve. Turn to pilot,
meter should read greater than
100mV.
Thermodisk
Pilot Lights with
Piezo Ignitor
YES
YES
YES
YES
Pilot Stays Lit
Pilot Lights Main
Burner
System OK
START
CHECK
Wall switch is not turned on.
Watch for grounded wires!
Thermopile needs a minimum
325mV
Plugged burner orifice
Doors not fully open (Fig. 10)
FP396
NVC-standing pilot troubleshooting
5/6/98
Nova SIT 820 Standing Pilot
15
ODGSR Series Outdoor Gas Fireplace
20007114
Maintenance
Burner and Burner Compartment
Itisimportanttokeeptheburnerandtheburnercompartment
clean.Atleastonceperyearthelogsshouldberemoved
and the burner compartment vacuumed and wiped out.
Remove and replace the logs as per the instructionsin
thismanual.
Always handle the logs with care as they are fragile and
may also be hot if the replace has been in use.
Cleaning
Therearethreemethodsofcleaningthepolishedstainless
steelofyouroutdoorreplace;
1. Warm,soapywater-toloosenanydirtlm
2. Glasscleanerwithammonia
3. Stainlesssteelcleaneravailableathardwarestores
Regardlessofwhichmethodisused,rememberthatany-
thingwithtoomuchabrasivemaydullthenish.
Cleaning the Standing Pilot
Control System
Theburnerandcontrolsystemconsistsof:
mainburner
• gasorice
• pilotburner
• thermopile
• combinationmillivoltgasvalve
Mostofthesecomponentsmayrequireonlyanoccasional
checkupandcleaningandsomemayrequireadjustment.
Ifrepairisnecessary,itshouldbeperformedbyaqualied
technician.
Inordertoproperlycleantheburnerandpilotassembly,
turnoffthegastotheunit,removelogsexposingtheburner
andpilotassembly.Cleanallforeignmaterialsfromthetop
oftheburner.Checktomakesurethatburnerpartsare
clean.Visuallyinspectpilot.Brushorblowawayanydust
orlintaccumulationIfpilotoriceisplugged,disassembly
mayberequiredtoremoveanyforeignmaterialfromthe
oriceortubing.
Toobtainproperoperation,itisimperativethatthepilot
and burner's ame characteristics are steady, not lifting
oroating.
Typically,thetop3/8"or1/2"ofthethermopileshouldbe
engulfedinthepilotame.(Fig.16)
Toadjustpilotburner,turnpilotscrewmarked"pilot"for
properamesize.
Theairshutterissetatfactorynoadjustmentshouldbe
necessary.
16
ODGSR Series Outdoor Gas Fireplace
20007114
7114
oduvsr36/42A
parts
11/24/03 DJT
4a/b
11
13
H
I
L
O
O
F
F
O
N
O
F
F
E A
P
I
L
O
T
THTP
TP
TH
14
12a/b
16
15
18a/b
6
9
10
a
b
d
c
h
c
d
a
b
f
e
2
3
7
8
17
20
g
19a/b
21
22
25
ODGSR36A, ODGSR42A
Ref. Description ODGSR36A ODGSR42A
1. Logs-CompleteSet 20007180 20007200
1a. Log-LeftRear 20007175 20007193
1b. Log-RightRear 20007176 20007194
1c. Log-RightCross 20007178 20007197
1d. Log-LeftCross 20007177 20007195
1e. Log-MiddleCross -- 20007196
1f. Log-LeftEmber -- 20007198
1g. Log-RightEmber -- 20007199
1h. FrontEmberLog 20007179 --
2. BurnerHousingAssembly 20007119 20007187
3. CeramicTile(single) 57803 57803
4a. BurnerOrice-Natural(Manifold&Orice) 20007106 20007106
4b. BurnerOrice-LP(Manifold&Orice) 20007159 20007159
6. SideBrick-Left* 20002008or92D0004 20002021or92D0011
7. BackBrick* 20002006or92D0002 20002019or92D0005
8. SideBrick-Right* 20002007or92D0003 20002020or92D0006
9. LeftHearthBrick* 20007158or92D0008 20007241or92D0010
10. RightHearthBrick* 20007157or92D0007 20007240or92D0009
11. Piezo 52464 52464
12a. PilotTopConvertible-Natural(3WayAssembly) 10002264 10002264
12b. PilotTopConvertible-LP(3Wayassembly) 10002265 10002265
13. Thermopile18" 7533113 7533113
VermontCastingsGroupreservestherighttomakechangesindesign,materials,specications,pricesanddiscontinuecolorsandproductsat
anytime,withoutnotice.
7114
1.ODGSR36ALogs 1.ODGSR42ALogs
17
ODGSR Series Outdoor Gas Fireplace
20007114
ODGSR36A, ODGSR42A (continued)
Ref. Description ODGSR36A ODGSR42A
14. PilotTubing 10001296 10001296
15. CableIgnitor24" 7522432 7522432
16. Thermocouple24" 7531137 7531137
17. Grate 20006819 20006819
18a. PilotOrice-Natural 10002268 10002268
18b. PilotOrice-LP 10002269 10002269
19a. ValveNOVA-Natural 7529141 7529141
19b. ValveNOVA-LP 7529142 7529142
20a. AirShutter-Natural 20009120 20000129
21. HearthBrickCover 20007183or92D0016 20007183or92D0016
22. Thermodisk 20007568 20007568
23. ConversionKitLPtoNatural 20008549 20008550
24. ConversionKitNaturaltoLP 20008548 20008551
25. ValveAccessPanelAssy 20009119 20008296
Contact Vermont Castings Group for questions concerning
prices and policies covering replacement parts. Parts may
beorderedthroughyourVermontCastingsGroupFireplaces
distributorordealer.
Youwillneedthefollowinginformationwhenorderingreplace-
mentparts:
1. Theappliancemodelnumber.
2. Theserialnumber.
3. Adescriptionofthepart.
Shouldyouneedadditionalinformationbeyondwhatyourdealer
canfurnish,contact:
VermontCastingsGroup
149ClevelandDrive
Paris,KY40361
Modeland serial numbersare listed on the rat-
ing plate (located on right side of combustion
chamber).
Recordyourmodelandserialnumbersherefor
futurereference:
Model# ____________________________
Serial# ____________________________
*Whenorderingreplacementrebrick,checktheserialnumberandplantcodeofthereplace,locatedontheULlabel
insidetherebox.Serialnumbers/plantcodewitha'P'requiretherebricklistedrstundertherespectivereplace
(whitebrick).Serialnumbers/plantcodewithan'X'requiretherebricklistedsecondundertherespectivereplace
(greybrick).
18
ODGSR Series Outdoor Gas Fireplace
20007114
Accessories
ThefollowingaccessoriesareavailablefromyourlocalVermontCastingsGroupFireplacesdistributor.Eachaccessory
comeswithaseparateinstallationinstructionformountingtotheparticularrebox.Besuretoreadeachinstruction
thoroughlybeforeinstalling.
CAUTION: This rebox is a highly engineered system, and, as such, must be operated only with Vermont Cast-
ings Group approved components. If you use an unapproved component to make any modications, you may
create a possible re hazard and will void the Vermont Castings Group warranty. In addition, such action may
void the coverage provided by the owner's insurance.
Accessory Description Model Number
4"StainlessSteel Forheaterupto40,000BTU'sandmantels UV36SH4
Hood 8"highby12"wide UV42SH4
GlassDoors Designedtoenhancethelookofthereplace 36GDKSSSR
42GDKSSSR
WeatherEnclosure Designedtoprotecttheburnerwhenunitisnotinuse ODG36WE
ODG42WE
DrainPan Designedtobeinstalledunderunittoshedwater 20014194(36"models)
bymeansofcontainingandpipingwayfromstructure 20014195(42"models)
19
ODGSR Series Outdoor Gas Fireplace
20007114
LIMITED LIFETIME WARRANTY
PRODUCT COVERED BY THIS WARRANTY
AllVermontCastingsgasstoves,gasinserts,andgasreplaces,andallMonessenandVermont
CastingsGroupbrandgasreplacesequippedwithanInsta-FlameCeramicBurner,orstandard
BASIC WARRANTY
Vermont CastingsGroup(hereinafter referred tocollectivelyas the
Company) warrants that your new Vermont Castings, Monessen
or Vermont Castings Group Gas Fireplace/Stove is free from
manufacturingandmaterialdefectsforaperiodofoneyearfromthe
dateofpurchase,subjecttothefollowingconditionsandlimitations.
EXTENDED LIFETIME WARRANTY
The heat exchanger, where applicable, and combustion chamber
ofeveryVermontCastings, Monessen or Vermont Castings Group
gasproductiswarrantedforlifeagainstthroughwallperforation.All
appliancesequippedwithanInsta-FlameCeramicBurnerhavelimited
lifetimecoverageontheceramicburnerplaque.Warranteesaremade
totheoriginalownersubjecttoproofofpurchaseandtheconditions
andlimitationslistedonthisWarrantyDocument
COMPONENT WARRANTY
CASTIRON:Allexternalandinternalcastironpartsarewarrantedfora
periodofthreeyears.
Note:OnporcelainenamelnishedexternalpartsandaccessoriesThe
CompanyoffersnoWarrantyonchippingofenamelsurfaces.Inspect
allproductpriortoacceptingitforanydamagetotheenamel.
Thesaltairenvironmentofcoastalareasorahighhumidityenvironment
canbecorrosivetotheporcelainenamelnish.Theseconditionscan
causerustingof the castironbeneath the porcelainenamelnish,
whichwillcausethenishtoakeoff.
Dyelotvariationswithreplacementpartsand/oraccessoriescanoccur
andarenotcoveredbywarranty.
GLASS DOORS: Glass doors are covered for a period of one year.
Glassdoorsarenotwarrantedforbreakageduetomisuseoraccident.
Glassdoorsarenotcoveredfordiscolorationorburnedinstainsdueto
environmentalissues,orimpropercleaningandmaintenance.
BRASSPLATED PARTSANDACCESSORIES: Brass partsshouldbe
cleanedwithLemonoilonly. Brasscleanerscannotbeused.Mortarmix
andmasonrycleanersmaycorrodethebrassnish.TheCompanywillnot
beresponsiblefor,norwillitwarrantanybrasspartswhicharedamaged
byexternalchemicalsordowndraftconditions.
GASVALVES:Gasvalvesarecoveredforaperiodofoneyear
ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and
mechanicalcomponentsoftheburnerassemblyarecoveredforoneyear.
Allsteeltubeburnersarewarrantedforoneyear.
ACCESSORIES:Unlessotherwisenoted,allcomponentsandVermont
CastingsGroupcompanysuppliedaccessoriesarecoveredforaperiod
ofoneyear.
CONDITIONS AND LIMITATIONS
• ThisVermontCastingsorVermontCastingsGroupproductmustbe
installedorservicedbyaqualiedinstaller,preferablyNFIorWETT
(Canada)certied,asprescribedbythelocaljurisdiction.Itmustbe
installedandoperatedatalltimesinaccordancewiththeInstallation
andOperatinginstructionsfurnishedwiththeproduct.Anyalteration,
willful abuse, accident, or misuse of the product shall nullify this
warranty.
• Thiswarrantyisnon-transferable,andismadetotheoriginalowner,
providedthatthepurchasewasmadethroughanauthorizedsupplier
oftheCompany.
• ThecustomermustpayforanyAuthorizedDealerin-hometravelfees
orservice charges forin-home repairwork.It isthedealers option
whethertherepairworkwillbedoneinthecustomer’shomeorinthe
dealer’sshop.
• If upon inspection, the damage is found to be the fault of the
manufacturer,repairswillbeauthorizedatnochargetothecustomer
partsand/orlabor.
• Any part and/or component replaced under the provisions of this
warrantyis coveredforsixmonthsor theremainder oftheoriginal
warranty,whicheverislongest.
• Thiswarrantyislimitedtotherepairoforreplacementofpart(s)found
tobedefectiveinmaterialorworkmanship,providedthatsuchpart(s)
havebeensubjectedtonormalconditionsofuseandservice,after
saiddefectisconrmedbytheCompany’sinspection.
• The company may, at its discretion, fully discharge all obligations
withrespecttothiswarrantybyrefundingthewholesalepriceofthe
defectivepart(s)
• Anyinstallation,labor,construction, transportation,orotherrelated
costs/expenses arising from defective part(s), repair,replacement,
orotherwiseofsame,willnotbecoveredbythiswarranty,norshall
theCompanyassumeresponsibilityforsame.Further,theCompany
willnotberesponsiblefor anyincidental,indirect,orconsequential
damagesexceptasprovidedbylaw.
SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR
LIMITATIONSOFINCIDENTALANDCONSEQUENTIALDAMAGES
OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY
LASTS,SOTHEABOVELIMITATIONSMAYNOTAPPLYTOYOUR
CIRCUMSTANCES. THIS WARRANTY GIVES YOU SPECIFIC
RIGHTSANDYOUMAYHAVEOTHERRIGHTSWHICHVARYFROM
STATETOSTATE.
• Allotherwarranties-expressedorimplied-withrespecttotheproduct,
itscomponentsandaccessories,oranyobligations/liabilitiesonthe
partoftheCompanyareherebyexpresslyexcluded.
• The Company neither assumes, nor authorizes any third party to
assumeonitsbehalf,anyotherliabilitieswithrespecttothesaleofthis
VermontCastings,MonessenorVermontCastingsGroupproduct
• Thewarrantiesasoutlinedwithinthisdocumentdonotapplytochimney
componentsorothernon-VermontCastingsGroupaccessoriesused
inconjunctionwiththeinstallationofthisproduct.
• Damagetotheunitwhileintransitisnotcoveredbythiswarrantybut
is subject to claim against the common carrier. Contact the dealer
fromwhomyoupurchasedyourreplace/stove(donotoperatethe
applianceasthismightnegatetheabilitytoprocesstheclaimwiththe
carrier).
• TheCompanywillnotberesponsiblefor:
a) Downdraftsorspillagecausedbyenvironmentalconditionssuch
asnear-bytrees,buildings,rooftops,hills,ormountains.
b) Inadequate ventilation or negative air pressure caused by
mechanicalsystemssuchasfurnaces,fans,clothesdryers,etc.
• Thiswarrantyisvoidif:
a) Thereplacehasbeenoperatedinatmospherescontaminatedby
chlorine,uorine,orotherdamagingchemicals.
b) The fireplace has been subjected to prolonged periods of
dampnessorcondensation
c) Any damages to the fireplace, combustion chamber, heat
exchangerorothercomponentsduetowater,orweatherdamage,
whichistheresultofbutnotlimitedto,improperchimney/venting
installation.
d) Anyalteration,willfulabuse,accident, ormisuseoftheproduct
hasoccurred.
IF WARRANTY SERVICE IS NEEDED…
1) Contactyoursupplier.Makesureyouhaveyourwarranty,your
salesreceipt,andthemodel/serialnumberofyourVermont
CastingsGroupproduct.
2) DO NOT ATTEMPT TO DO ANY SERVICE WORK
YOURSELF.
Vermont Castings Group
149ClevelandDrive•Paris,Kentucky40361
www.vermontcastingsgroup.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Vermont Castings ODGSR42A Operating instructions

Category
Fireplaces
Type
Operating instructions
This manual is also suitable for

Vermont Castings ODGSR42A is a gas fireplace designed for outdoor use, providing warmth and ambiance to your patio or backyard. Its high temperatures make it suitable for use in both residential and commercial settings, and it can be installed in various locations, including screened porches, exterior chases, and even directly on combustible materials with a protective metal or wood panel. The ODGSR42A operates on either natural gas or liquid propane, and its gas inlet and manifold pressures can be adjusted to suit your specific gas supply.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI