Raychem Jonction en ligne WSTK, kit de T avec joint d’extrémité Installation guide

Type
Installation guide

This manual is also suitable for

DESCRIPTION
For use with the following nVent RAYCHEM heating cables:
GM-1X, GM-2X,
WFP-312, WFP-322,
WFP-612, WFP-622,
WFP-812, WFP-822
for pipe heating and de-icing and snow melting applications.
TOOLS REQUIRED
Utility knife 
Diagonal cutters 
Needle-nose pliers
Heat gun or propane torch with flame spreader
Crimp tools (Ideal 30-425 and T&B WT112M or WT2000)
Hammer and nail (for gutter/downspout applications only)
IMPORTANT
The minimum installation temperature for the nVent
RAYCHEM WSTK Splice Tee Kit is 0°F.
APPROVALS
Charring or burning the heat-shrinkable tubes in this
kit will produce fumes that may cause eye, skin, nose,
and throat irritation. Consult Material Safety Data
Sheet RAY/3122.
CHEMTREC 24-hour emergency telephone:
(800) 424-9300.
Non-emergency health and safety information:
(650) 361-4907.
WARNING: CAUTION:
KIT CONTENTS
Item QTY Description
A 2 Insulated bus wire crimp
B 1 Uninsulated braid crimp
C 3 Cable ties
D 6 Mastic strips
E 1 Black heat-shrinkable cap
F 1 Black heat-shrinkable cap (
1"
diam x
6"
long)
G 1 Black cloth tapes (
1"
diam x
6"
long)
H 1 Clamp tie
I 1
Black heat-shrinkable tube " diam x 1 ½" long)
J 1
Black heat-shrinkable tube (¾" diam x 3" long)
K 2 Aluminum tapes
These components are electrical devices. They must be
installed correctly to ensure proper operation and to
prevent shock or fire. Carefully follow all of the installation
instructions and read these important warnings.
To minimize the danger of fire from sustained electrical
arcing if the heating cable is damaged or improperly
installed, and to comply with the requirements of nVent
and the National Electrical Codes, ground-fault equipment
protection must be used on each heating cable branch
circuit. Arcing may not be stopped by conventional circuit
breakers.
Component approvals and performance are based on the
use of specified parts only. Do not use substitute parts or
vinyl electrical tape.
The black heating-cable core is conductive and can short.
It must be properly insulated and kept dry.
Keep components and heating cable ends dry before and
during installation.
Damaged bus wires can overheat or short. Do not break bus
wire strands when scoring the jacket or core.
Bus wires will short if they contact each other. Keep bus
wires separated.
Heat-damaged components can short. Use a heat gun or
a torch with a soft, yellow flame. Keep the flame moving to
avoid overheating, blistering, or charring the heat-shrinkable
tubes. Avoid heating other components. Replace any
damaged parts.
Use only fire-resistant insulation materials such as
fiberglass wrap.
Leave these installation instructions with the user for future
reference.
A
B
C
H
I
J
D
E
EK
E
G
Listed 718K Pipe Heating Cable
& 8772 Deicing & Snowmelting
Equipment
-WS
WSTK Splice / Tee Kit with End Seal
Installation Instructions
2 | nVent.com
Tee Connection Installation
Bus wires
Core
Inner jacket
Braid
Outer jacket
1
GM-1X, GM-2X, WFP-312, WFP-322 WFP-612, WFP-622,
WFP-812, WFP-822
2 in
1 in
1/4 in
1/4 in
2
4 5
12 in
1
3
Lightly score completely
around and then down
outer jacket.
Bend heating cable to break
jacket at score then peel off
outer jacket.
At the end of
each heating-
cable section
lightly score
completely
around and down
inner jacket.
Bend heating cable to break
jacket at score, then peel
off inner jacket.
Allow 12 in of extra
heating cable as
shown. If necessary
trim cables evenly.
Unravel the braid back to the outer jacket.
Position braid on same side of each heating cable
section.
Straighten the braid and twist into a “pigtail”.
Notch core at the end.
Twist back and peel bus
wires from core.
Do not cut braid
or inner jacket.
Do not cut bus wires.
nVent.com | 3
Tee Connection Installation
Mastic
1 in
2 in
9 in
6 in
6
7
9
Mastic
1/4 in
Pinch
8
Score between bus
wires at base jacket.
Bend core to break
free at base jacket.
Remove release paper from mastic strip.
Wrap a piece of mastic around the outer jacket on each
heating cable section.
Carefully align the
heating cable sections
and place them
together.
Press mastic strips
firmly together.
Remove release paper from mastic strip.
Wrap a piece of mastic around the end of each heating
cable section and position as shown.
Pinch the mastic in the center to completely seal the
core at the end of each heating cable.
Peel core and any remaining
material from bus wires.
Repeat steps 2 through 6 for
other heating cable sections.
Do not cut
bus wires.
Fasten with
a cable tie at
each of the two
positions shown.
4 | nVent.com
Tee Connection Installation
1/4 in
Black tape
Place edge of
tube at edge
of mastic
Approx.
4-1/2 in
6-in tube
10
11
13 14
12
Twist the braid
pigtails together.
Fold the crimped braid back against the heating cables.
Wrap black cloth tape evenly around crimp and heating
cables. Cover crimp completely.
Repeat with
remaining
bus wires.
Be careful not to
twist together bus
wires from the same
heating cable.
Slide heat-shrinkable cap over bus wire crimps.
It is not necessary to shrink cap.
Select one bus wire
from each cable
section and twist the
wires together.
Position the 6-inch-long
heat-shrinkable tube as
shown.
Slide uninsulated crimp
over braid to within 1/4 in of
heating cable as shown.
Crimp the braid, using the
Ideal crimp tool.
Cut off the extra braid.
Use insulated bus wire crimps
and T&B crimp tool to crimp
each set of bus wires together.
nVent.com | 5
Tee Connection Installation
Ring of mastic
and adhesive
will appear
15
Shrink the tube completely. Start at
end farthest from the cap and work
toward the open end.
Keep heating after tube has shrunk, to melt
adhesive and mastic inside tube. Total heating
time should be about 5 minutes.
1 in
Important:
Additional
heat is needed
after the tube is
shrunk to melt
mastic and adhe-
sive inside.
Immediately after shrinking, pinch the
end of the tube with needle-nose
pliers until the end stays sealed;
this normally takes 10
seconds.
CAUTION: Health Hazard.
Consult material safety
data sheet RAY3122.
CAUTION: To
avoid burns
allow heated
sections to
cool before
touching.
16
18
17
19
Lay the first piece of aluminum tape as shown.
Ensure the edge of the tape is 1" away from the mastic.
Lay the second piece of tape on the opposite side.
Press and form the aluminum tape onto the heat shrink tube.
Press and form the second piece of the aluminum tape onto
the first piece of the aluminum tape. Ensure the heat shrink
tube is fully covered by the tapes.
6 | nVent.com
Tee Connection Installation
H915
Secure end of
connection to
heating cable
20
21B
21A
Fold back the tape at the end.
WinterGard Wet gutter and downspout applications.
For applications except WinterGard Wet in gutters and
downspouts.
Secure heating cable with down-spout
hanger (H915).
Fasten clamp tie to center of connection.
Use a hammer, nail, and clamp tie to
secure connection and keep it off of
the gutter bottom as shown.
After the connection has cooled,
fold over the connection and
fasten it with the third cable tie.
nVent.com | 7
End Seal Installation
2 in
(50 mm)
1
Bus wire
Conductive core
Inner jacket
Braid
Outer
jacket
For use with BTV-CR, BTV-CT and QTVR-CT heating cables only.
Lightly score outer
jacket around and
down as shown.
Bend the heating cable
to break jacket at score
then peel off jacket.
GM-1X, GM-2X, WFP-312, WFP-322, WFP-612,
WFP-622, WFP-812, WFP-822
1 ¹⁄4 in
(30 mm)
¹⁄2 in
Short
tube
2 3
Note: If using a propane torch,
use a flame spreader to prevent
damage to the tube
Push back braid to expose
the inner jacket. Do not cut
off the braid wires.
Cut off end of heating
cable leaving 1 1/4" - inch
inner jacket.
Refer to Materials Safety
Data Sheet Ray 3122.
Position short tube over end
of heating cable as shown.
Heat tube until it shrinks and
adhesive flows out ends.
While still hot, gently pinch
end and hold for 10 seconds.
Allow tube and braid
wires to cool completely.
1/4 in
(6 mm)
3/4 in
(20 mm)
Long tube
4 5
Pull the braid over the
recovered tube and
twist the end.
Trim braid 1/4" - inch
from end of tube.
Smooth down any
exposed, sharp,
braid wire ends.
Refer to Materials Safety
Data Sheet Ray 3122.
Slide long tube over the braid
and outer jacket and position
as shown.
Heat tube until is shrinks
and adhesive flows out
ends.
While still hot, gently
pinch end and hold for
10 seconds.
Allow tube to cool
completely.
IMPORTANT
All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their particular
application. nVent makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. nVent's only obligations
are those in the nVent Standard Terms and Conditions of Sale for this product, and in no case will nVent or its distributors be liable for any incidental, indirect, or
consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, nVent reserves the
right to make changes - without notification to Buyer - to processing or materials that do not affect compliance with any applicable specification.
©2019 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its aliates. All other trademarks are the property of their respective owners.
nVent reserves the right to change specications without notice.
RAYCHEM-IM-H59369-RIMWSTK-EN-1908 P000000244
nVent.com
North America
Tel +1.800.545.6258
Fax +1.800.527.5703
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Raychem Jonction en ligne WSTK, kit de T avec joint d’extrémité Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI