Kichler Lighting 42498NI is a chain hung light fixture that can be used to provide illumination in a variety of settings. The fixture is designed to be installed in accordance with the National Electrical Code (NEC) and all local code specifications. It comes with a mounting strap, mounting screws, decorative loops, a canopy, a lockwasher, a hexnut, chain, a metal trim, a safety cable, knobs, and lockwashers. The fixture is easy to install and can be adjusted to the desired length. It is also equipped with a ground wire for safety.

Kichler Lighting 42498NI is a chain hung light fixture that can be used to provide illumination in a variety of settings. The fixture is designed to be installed in accordance with the National Electrical Code (NEC) and all local code specifications. It comes with a mounting strap, mounting screws, decorative loops, a canopy, a lockwasher, a hexnut, chain, a metal trim, a safety cable, knobs, and lockwashers. The fixture is easy to install and can be adjusted to the desired length. It is also equipped with a ground wire for safety.

IS-42498-US
Were here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
6) Slip loop of safety cable[N] over end of threaded pipe
protruding from inside of canopy.
7) Pass xture wire through lockwasher[E]. Place
lockwasher onto end of threaded pipe protruding from
inside canopy.
8) Pass xture wire through hexnut[F]. Thread hexnut onto
end of threaded pipe.
9) Adjust chain to desired length at this me and aach
chain[A] to decorave loops by opening one chain
link, close the open links by wrapping with a towel and
squeezing closed using pliers.
10) Weave electrical wire and ground wire through chain
links[A] no more than 3 inches apart and run into the
canopy.
11) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, and thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector aer following the above steps. Never connect
ground wire to black or white power supply wires.
12) Make wire connecon. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
13) Aach the inspecon cable[N] to the mounng strap
or to the inside of the mounng box. Raise canopy
to ceiling. NOTE: Be certain wires do not get pinched
between the canopy and ceiling.
14) Use knobs[J] and lockwashers[K] to secure canopy.
Tighten to secure.
15) Insert recommended bulbs (Not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
[A] Chain
[B] Decorative
Loop
[C] Main Body /
Fixture
[D] Canopy
[E] Lockwasher
[F] Hexnut
[G] Mounting
Strap
[H] Mounting
Screws
[I] Outlet Box
[J] Knobs
[K] Lockwashers
[L] Strap
Mounting
Screws
[M] Metal Trim
[N] Safety Cable
/ Inspection
Cable
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
CHAIN HUNG:
1) Find the appropriate threaded holes on mounng
strap[G]. Assemble mounng screws[H] into threaded
holes.
2) Aach mounng strap to outlet box[I] using the supplied
strap mounng screws[L]. The mounng strap can be
adjusted to suit posion of xture.
3) Place the metal trim[M] on top of the main body[C].
4) Aach one decorave loop[B] to xture[C].
5) Aach the other decorave loop[B] to the canopy[D].
I
G
L
E
F
H
D
K
J
B
A
B
M
N
C
IS-42498-CB
Were here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
6) Slip loop of safety cable[N] over end of threaded pipe
protruding from inside of canopy.
7) Pass xture wire through lockwasher[E]. Place
lockwasher onto end of threaded pipe protruding from
inside canopy.
8) Pass xture wire through hexnut[F]. Thread hexnut onto
end of threaded pipe.
9) Adjust chain to desired length at this me and aach
chain[A] to decorave loops by opening one chain
link, close the open links by wrapping with a towel and
squeezing closed using pliers.
10) Weave electrical wire and ground wire through chain
links[A] no more than 3 inches apart and run into the
canopy.
11) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, and thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector aer following the above steps. Never connect
ground wire to black or white power supply wires.
12) Make wire connecon. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
13) Aach the inspecon cable[N] to the mounng strap
or to the inside of the mounng box. Raise canopy
to ceiling. NOTE: Be certain wires do not get pinched
between the canopy and ceiling.
14) Use knobs[J] and lockwashers[K] to secure canopy.
Tighten to secure.
15) Insert recommended bulbs (Not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
[A] Chain
[B] Decorative
Loop
[C] Main Body /
Fixture
[D] Canopy
[E] Lockwasher
[F] Hexnut
[G] Mounting
Strap
[H] Mounting
Screws
[I] Outlet Box
[J] Knobs
[K] Lockwashers
[L] Strap
Mounting
Screws
[M] Metal Trim
[N] Safety Cable
/ Inspection
Cable
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
CHAIN HUNG:
1) Find the appropriate threaded holes on mounng
strap[G]. Assemble mounng screws[H] into threaded
holes.
2) Aach mounng strap to outlet box[I] using the supplied
strap mounng screws[L]. The mounng strap can be
adjusted to suit posion of xture.
3) Place the metal trim[M] on top of the main body[C].
4) Aach one decorave loop[B] to xture[C].
5) Aach the other decorave loop[B] to the canopy[D].
I
G
L
E
F
H
D
K
J
B
A
B
M
N
C
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Kichler Lighting 42498NI User manual

Type
User manual

Kichler Lighting 42498NI is a chain hung light fixture that can be used to provide illumination in a variety of settings. The fixture is designed to be installed in accordance with the National Electrical Code (NEC) and all local code specifications. It comes with a mounting strap, mounting screws, decorative loops, a canopy, a lockwasher, a hexnut, chain, a metal trim, a safety cable, knobs, and lockwashers. The fixture is easy to install and can be adjusted to the desired length. It is also equipped with a ground wire for safety.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI