Pulsar AWZ529 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Pulsar AWZ529 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
2
L2
I2
2
3
L1
I1
MP2
AWZ529
v.2.0
MP2
Relay module
Edition: 4 from 01.03.2018
Supersedes the edition: 3 from 10.07.2013 EN
1. Intended use.
The MP2 (AWZ529) relay module is to be used in low-voltage installations. It is intended for controlling and status
indication in e.g. alarm or access control systems. It may be used to control devices of high power consumption via OC outputs of
alarm systems. Moreover, it ensures galvanic isolation of signals, power sources relating to the outputs of the module.
2. Installation.
The module is equipped with a plastic panel with self-adhesive tape that enables fixing it to a flat surface (side panel of an
enclosure, a buffer PSU, etc.) and holes for bolting the panel to the mounting surface.
3. Description of the module.
3.1 Components. 3.2 Connectors.
4. Specifications.
Fig. 1. General view of the module.
5. Electrical diagram.
-I+ inputs of the voltage that control the relay
C1, C2 common terminal of the relay
NO1, NO2 normally open relay’s contact
NC1, NC2 normally closed relay’s contact
1 LED (indicates relay’s operations)
2 relay
3 module terminals
Voltage of the relay’s coil
10÷14V DC (-/+5%),
Current of the relay’s coil
37mA@12VDC
Number of relays
2
Voltage of the relay’s contacts
30VDC / 50VAC max.
Current of the relay’s contacts
2A max.
Contacts of relay
C/NC/NO (leads Φ2.05 mm: AWG 24-12)
ON/OFF time
15ms/8ms (-/+5%)
Operating conditions
2nd environmental class, -10°C÷ 40°C
Enclosure
open-frame design, IP00
Dimensions
L=70, W=43, H=22 [mm, +/-2]
Net/gross weight
0,04 / 0,06 [kg]
Installation
installation tape or installation bolt x2
Declarations, warranty
CE, 2 year from the production date
Notes
leads on connections:Ø 0,41÷1,63
(AWG 26-14),
Ø 0,51÷2,05 (AWG 24-12) - relay contacts
WEEE PARKING
According to the EU WEE Directive It is required not to dispose of electric or electronic waste as unsorted municipal waste
and to collect such WEEE separately.
Zużytego sprzętu elektrycznego i elektronicznego nie wolno wyrzucać razem ze zwykłymi domowymi odpadami. Według dyrektywy WEEE
obowzującej w UE dla zużytego sprzętu elektrycznego i elektronicznego należy stosować oddzielne sposoby utylizacji.
/