Toto Clean Dry HDR100 GY Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Toto Clean Dry HDR100 GY Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
INSTALLATION MANUAL Clean Dry™
High Speed Hand Dryer
Important Safeguards
(For your safety, please follow the instructions below.)
In this Instruction Manual, the following symbols are shown for safe and proper use
of your automatic faucet and in order to alert you to the possibility of personal injury
and damage to your property.
The symbols and their meanings are as follows.
Warning
Ignoring these symbols may cause
personal injury and/or property damage.
*Some models may have different components from the ones illustrated below.
Do not install the unit in the places where corrosive
or combustible gas can be present.
This may cause product failure or damage.
Do not use in
humid area
Warning
Never attempt to disassemble for repair or
modification.
This may cause electric shock, fire, injury or failure
Do not install outdoors or where it is exposed to
water.
This may cause current leakage, electric shock, fire, or failure.
Do not
disassemble
Specification
0GU3040 2008.04
Do not
Caution
Ignoring these symbols may cause
severe injury and/or property damage.
Product HDR100#GY
Power Rating 120V AC, 4.25 Amps, 60 Hz, 510 W
Power Saving Function Automatically turns OFF after 60 seconds of use
62 dB
Ambient temperature 32°-104°F (0°-40°C)
Size
9-5/8" x 18-1/2" x 6-5/16"
Decibel Rating
Power Connection
Hardwiring
224 mph (100 meters/second)
Air Speed
12 seconds
Dry Time
0.20 gal (700 ml)
Drain Tray Capacity
Weight
10 lbs (4.5kg)
Warning
It is recommended to install a circuit-breaker in the power supply
Important
Failure to do this may cause electric shock during overload or short
circuit.
Caution
The chassis assembly must be installed on a smooth and even
wall surface which has enough strength.
Important
Failure to do this may cause damage or personal injury if it falls down.
Notice
Do not!
Do not place anything beneath the unit; leave a clearance
of 3-15/16” (100mm). Do not install on uneven wall surface.
If air flow is not good, the product may not perform well .
Before Installing
1.
Precautions
2. Others
Confirm the rough-in, major dimensions and wiring diagram before installation
in order to properly install the hand dryer and electrical wiring.
All electrical wiring should be installed in accordance with national/local codes
and regulations with an assistance from a certified electrician.
Clearance for drain tray, shown in Set-up Drawing, is required for proper air
flow into the unit and maintenance of the tray.
Mounting surface should be even and smooth.
Confirmation must be made that the wall has enough strength for hand dryer
installation and be sure to use all the mounting harware provided to securely
install the hand dryer.
It is necessary to install circuit breaker for the power supply.
Pay special attention so that both top cover and sensor surface are not flawed
or scratched.
Do not place other devices using inverter or infrared sensor near the
hand dryer, this may cause malfunction.
Set-up Drawing
Some models may have different components as illustrated below.
3-1/16
(77mm)
2-1/4”
(57mm)
3 HOLE
BRACKET
DIA. 5/32”
(4mm)
ELECTRICAL
INLET
7/8” (22mm)
DIA. HOLE
*
6-5/16”
(162mm)
9-5/8”
(245mm)
DRAIN TRAY
ASSY*
DRAIN
TRAY
CLEARANCE
FOR DRAIN TRAY
AND AIR FLOW PATH**
FINISHED
WALL
9.5/8”
(245mm)
18-1/2”
(470mm)
7-13/16”
(199mm)
9-7/16”
(240mm)
6-11/16”
(170mm)
7-13/16”
(199mm)
9-7/16”
(240mm)
5/8”
(16mm)
5/8”
(16mm)
18-1/2”
(470mm)
10-3/8”
(263mm)
FLOOR
POWER CABEL
Ø4.5X30 (mm)
SCREW
Ø4.5X30 (mm)
SCREW
Ø4.5X30 (mm)
SCREW
3-15/16”
(100mm)
7-1/8”
(180mm)
8-7/8”
(224mm)
2-1/4”
(57mm)
TOP COVER
ASSY UNIT*
*Top Cover Assy Unit and Drain Tray Assy are two separate parts.
**Clearance is required in order to take off the tray for cleaning and maintenance
and have good air flow into the unit.
6-5/16”
(160mm)
4-5/16
(110mm)
7
(177mm)
(HARDWIRING)
9-5/8”
(245mm)
18-1/2”
(470mm)
6-5/16”
(162mm)
DIA. MOUNTING
HOLES (4)
5/32” (4mm)
(actual placement)
Junction box
*
Recommended mounting bracket heights from floor are as follow:
-Male/Female: 53” (1346 mm)
-Children: 47” (1194 mm)
-Handicapped: 45” (1143 mm)
Meets the American Disabilities Act Guidelines, ANSI A117.1 and CSA B651 requirements
when mounted in a recessed wall where the front surface is not more than 4” (102mm) from
finished wall and max. height of air blower outlet from finished floor is 47-1/4” (1200mm).
Installation
*Some models may have different component as illustrated below.
POWER
ON
OFF
φ4.5×30X7
<Bottom view>
<View with cover removed>
Hand Dryer Unit
w/o Top Cover
Accessories
Chassis Assy.
Filter
Filter case
Filter case
Wall surface
Sensor
air nozzles
Junction box
Power switch
(Connection
type)
Top cover
Drain Tray
Assy
Drain tray
back of Drain
Tray Assy.
Installation
position
Platform for
Mounting bracket
Model is subject to change without further notification.
Mounting Bracket Screws and vandal resist Hex Wrench Template
Owner’s and Installation
manual
Installation Procedure
To be continued on the back
1
Use template, mark the wall
for locations and install the mounting
bracket.
Top cover
Chassis
Assy.
Drain Tray
Assembly
Drain Tray
Mounting
Bracket
junction box
location
φ4.5×30
φ4.5×30
Attach the bracket firmly on the rigid wall with three screws (φ4.5×30)
provided.
In the case of a tile or concrete wall, please use plastic plug anchors with
screws provided.
Mark the wall with template and install the bracket
Caution
Chassis Assy. must be installed on a rigid and even surface
Failure to do this may cause damage or personal injury when it falls.
Screw (x3)
Screw (x4)
Floor surface
2
Complete the electrical wiring; install the junction
box,and connect the power cord using wire nuts.
3
Mount the Chassis Assembly and Drain Tray
Assembly
4
Install the top cover and drain tray
3-1/16
(77mm)
2-1/4”
(57mm)
3 HOLE
BRACKET
DIA. 5/32”
(4mm)
ELECTRICAL
INLET
7/8” (22mm)
DIA. HOLE
9-5/8”
(245mm)
18-1/2”
(470mm)
7-13/16”
(199mm)
9-7/16”
(240mm)
6-11/16”
(170mm)
7-1/8”
(180mm)
8-7/8”
(224mm)
2-1/4”
(57mm)
DIA. MOUNTING
HOLES (4)
5/32” (4mm)
(actual placement)
Junction box
53”
(1346mm)
46-3/4”
(1186mm)
45-3/16”
(1147mm)
35-3/4”
(907mm)
STEP 1
STEP 1
*
Recommended mounting bracket heights from floor are as follow:
-Male/Female: 53” (1346 mm)
-Children: 47” (1194 mm)
-Handicapped: 45” (1143 mm)
*
STEP 2
STEP 4
STEP 2
Complete the electrical wiring
STEP 3
Mount the Chassis Assembly and Drain Tray
Assembly
Use the special hex wrench provided to remove the 2 screws (φ4×10)
from the top cover, then remove the cover.
To remove the top cover, pull the lower part towards you and pull
the upper part upward, then remove it.
Hang Chassis Assy. mounting platform onto mounting bracket hooks..
Connect the power cord inside the main body case with the power cord
out of the wall and use wire nuts (certified electrician to confirm the specific
wire nut to use).
Vandal resist Screw
for Top cover (x2)
Top cover
Chassis Assembly
mounting platform
Chassis
Assembly
mounting bracket hooks
mounting
bracket
Connection point
Connection
diagram
Connect the cord firmly with a wire nut or equivalent.
(Actual Placement)
Junction box
Chassis
Assembly
Drain Tray
Assembly
Put the connection point (with wire nuts) into the junction box.
Hang the Chassis Assembly onto the mounting bracket.
Insert the Drain Tray Assy. into the bottom of the Chassis Assembly, and attach
the lower part of the Drain Tray Assy. to the Chassis Assy. with 2
screws (Ф4.30) provided.
(Actual Placement)
Junction box
mounting
bracket
STEP 4
Install the top cover and drain tray
φ4×10
Drain Basin
Drain tray
Drain Tray
Assembly
Top cover
hook of Top cover
Chassis Assembly
Screw for Top cover (x2)
Insert the hook of the top cover into the slot at the upper part
of the Chassis Assembly, then put the cover down.
Slot at the upper part of
the Chassis Assy.
Then, fasten the cover with two screws (Ф4×10) that were previously
taken out.
When installing the drain tray,
slide it completely into its maximum
depth.
* POWER MUST BE IN OFF POSITION DURING INSTALLATION.
1.
2.
3.
After trial run
Test the product as follow after the installation is complete.
Check the main Power Supply Switch.
Check the functionality
Check the power switch of the hand dryer
Turn on the main power supply switch on.
Turn the power swtich ON.
Place your hand under the outlet nozzles to see if air blows out.
After you check the functionality by trial run, give the User Manual
(with Warranty) to the customer, and explain how to use and maintain the
product.
First peel off the seal on the filter.
(The seal is used to protect the filter from scratches during
shipment; it is no longer needed.)
Peel off the seal
Power Switch
Air nozzles
B=BLACK
R=RED
W=WHITE
Bu=BLUE
G=GREEN
Sensor
Control
Assembly
Motor
Power
Connector
Power Fuse
Power
Switch
Motor
G
B
W
B
W
W
B
Bu
W
W
R
P1-1
P1-2
P3
P2
P7
P4
P5
P6
Function Test
1. Checking after installation
Wiring Diagram
/