Samsung AC-M50ANSA/DU User manual

Category
Air purifiers
Type
User manual

This manual is also suitable for

QUESTIONS OR COMMENTS?
COUNTRY CALL OR VISIT US ONLINE AT
U.A.E 800-SAMSUNG (726-7864) www.samsung.com
OMAN 800-SAMSUNG(726-7864)
www.samsung.com/ae (English)
www.samsung.com/ae_ar (Arabic)
KUWAIT 183-2255 (183-CALL)
www.samsung.com/ae (English)
www.samsung.com/ae_ar (Arabic)
BAHRAIN 8000-4726
www.samsung.com/ae (English)
www.samsung.com/ae_ar (Arabic)
QATAR
HHP & NPC ONLY
800-2255 (800-CALL)
www.samsung.com/ae (English)
www.samsung.com/ae_ar (Arabic)
EGYPT 08000-726786 www.samsung.com
ALGERIA 0800 100 100 www.samsung.com/n_africa
PAKISTAN 0800-Samsung (72678) www.samsung.com/pk/
TUNISIA 80-1000-12 www.samsung.com/n_africa
JORDAN
0800-22273
06 5777444
www.samsung.com/Levant(English)
SYRIA 18252273 www.samsung.com/Levant(English)
IRAN 021-8255 www.samsung.com
MOROCCO 080 100 2255 www.samsung.com
SAUDI ARABIA 920021230 www.samsung.com/sa
AC-M50ANSA Series_IB_EN_33977A(4).indd 20 2013-07-08 오후 6:07:07
DB98-33977A(4)
AREN
AC-M50ANSA Series
AC-505CM Series
Air Purifier
user manual
imagine the possibilities
Thank you for purchasing this Samsung product.
To receive more complete service, please
register your product at
www.samsung.com/register
This product is not manufactured for Iran. SVC
Warranty will not be applicable and the user will
be responsible for service expenses when the
product is used in Iran.
AC-M50ANSA Series_IB_EN_33977A(4).indd 21 2013-07-08 오후 6:07:07
2
Features
Multifunctional high efficiency air purifier
Convenient mode selection for dierent environments
- You can select Auto, Dust, Sleep, and Deodo mode for your dierent indoor environments.
Low noise and energy saving
- The high efficiency motor of the air purifier will not only generate noise at a low level but also reduce the electricity bill.
In addition, the standby power of the air purifier consumes less than below 1W, which will reduce energy consumption
when the appliance is not used for a long-term period.
Filter system
Deodorization filter + DNAlter
- The Deodorization + DNAlter will efficiently remove not only the harmful odors generated from wallpaper, adhesive
and furniture, but also the general odors of a home.
High performance purifying system
Efficient dust collection
- The Dust collecting filter of the air purifier will completely filter the invisible fine dust.
Outstanding deodorization function
- The use of the high performance activated carbon filter will quickly remove the odor of food, cigarettes etc.
Virus Doctor function
- The active hydrogen and ion produced by S-plasma ion function of your air purifier will remove indoor floating germ,
virus, and allergen.
Super sensor
- The dust sensor and odor sensor will detect dust and odors and then display the level of indoor air contamination
before automatically starting optimized operation mode.
Deodorization
filter section
Dust collecting filter
section
Pre-filter Dust collecting filterDeodorization filter
+ DNAlter
Virus Doctor
AC-M50ANSA Series_IB_EN_33977A(4).indd 2 2013-07-08 오후 6:07:02
3
Safety precautions
These safety precautions are for owner’s safety and preventions of property damage. Therefore, please read this manual
thoroughly before using your air purifier.
Important safety symbols and precautions :
WARNING
Hazards or unsafe practices that may result in severe personal injury or death.
CAUTION
Hazards or unsafe practices that may result in minor personal injury or property damage.
Follow directions.
Do NOT attempt.
Make sure the machine is grounded to prevent electric shock.
Unplug the appliance.
Do NOT disassemble.
FOR INSTALLATION
WARNING
Plug the power cord into a wall socket with the power specifications of the product or higher and use the socket
for this appliance only. In addition, do not use an extension cord.
Sharing a wall socket with other appliances using a multi outlet power strip or extending the power cord may
result in electric shock or fire.
Do not use an electric transformer. It may result in electric shock or fire.
If the voltage/frequency/rated current condition is different, it may cause electric shock orre.
Contents
Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Name of each part . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Check before use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Product dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Auto mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Dust mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Sleep mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Deodo mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Virus Doctor function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Timer function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Adjusting FAN speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Beneficial tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Cleaning and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Preparation
Basic function
Advanced function
Other information
AC-M50ANSA Series_IB_EN_33977A(4).indd 3 2013-07-08 오후 6:07:02
4
Safety precautions
FOR INSTALLATION
WARNING
Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or
dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a
location where gas may leak.
Failure to do so may result in electric shock orre.
FOR INSTALLATION
CAUTION
Install your appliance on a level and hard floor that can support its weight.
Failure to do so may result in abnormal vibrations, noise, or problems with the product.
Check whether there is a blockage around the air inlet or air outlet.
Failure to do so may result in product malfunction and reduced air purifying efficiency.
FOR POWER SUPPLY
WARNING
When the circuit breaker is damaged, contact your nearest service center.
Connect the power plug firmly into the wall socket. Do not use a damaged power plug, damaged power cord or
loose wall socket.
Failure to do so may result in electric shock orre.
Do not pull the power cord, when unplugging the appliance.
Unplug the appliance by holding the plug.
Failure to do so may result in electric shock orre.
Do not pull or excessively bend the power cord. Do not twist or tie the power cord. Do not hook the power cord
over a metal object, place a heavy object on the power cord, insert the power cord between objects, or push the
power cord into the space behind the appliance.
Failure to do so may result in electric shock orre.
FOR POWER SUPPLY
CAUTION
When not using the air purifier for a long period of time or during a thunder/lightning storm, disconnect the
power supply.
Failure to do so may result in electric shock orre.
FOR OPERATION
WARNING
If the appliance is flooded, turn off the appliance and contact a service center.
If the appliance generates a strange noise, a burning smell or smoke, disconnect the power supply immediately
and contact a service center.
Failure to do so may result in electric shock orre.
In the event of a gas leak (such as propane gas, LP gas, etc.), ventilate immediately without touching the power
plug.
Do not use a ventilating fan.
A spark may result in an explosion or fire.
Do not touch the power plug with wet hands.
Failure to do so may result in electric shock.
Do not unplug the appliance during operation.
When plugging the appliance in again,ame may occur and it may result in electric shock orre.
After unpacking the air purifier, keep all packaging materials out of the reach of children.
If a child places a bag over its head, it may result in suffocation.
AC-M50ANSA Series_IB_EN_33977A(4).indd 4 2013-07-08 오후 6:07:02
5
Do not insert yourngers or foreign substances into the air inlet or air outlet.
Take special care that children do not injure themselves by inserting their fingers into the appliance.
Do not strike or pull the appliance with excessive force.
Failure to do so may result inre, injury, or problems with the product.
When the appliance is used with a combustible apparatus in a closed area, ventilate the area at times.
The carbon monoxide and some harmful substances generated during combustion might not be removed.
If any foreign substance such as water has entered the appliance, disconnect the power supply and contact a
service center.
Failure to do so may result in electric shock orre.
Do not attempt to repair, disassemble, or modify the appliance yourself.
Do not use any fuse (such as copper, steel wire, etc.)other than the standard fuse.
Failure to do so may result in electric shock, fire, problems with the product or injury.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
FOR OPERATION
CAUTION
Do not stand on top of the appliance or place objects (such as laundry, lighted candles, lighted cigarettes,
dishes, chemicals, metal objects, etc.) on the appliance.
Failure to do so may result in electric shock, fire, problems with the product or injury.
Do not operate the appliance with wet hands.
Failure to do so may result in electric shock.
Do not spray volatile material such as insecticide onto the appliance.
As well as being harmful to humans, it may also result in electric shock, fire or problems with the appliance.
Do not open the filter box door during operation.
If you open the filter box door during operation, the operation will stop. Close thelter box door and press
[Power] button to turn on the air purifier again.
Make sure that moisture produced by a humidifier does not come into contact with the appliance.
Failure to do so may result in electric shock orre.
Failure to do so may result in abnormal operation of a sensor and odor from a filter.
Do not tilt or place the appliance in wrong position.
Failure to do so may result in product malfunction or fire.
Do not use the air purifier as a ventilator or range hood.
Failure to do so may result in reduced life of the appliance.
Do not use the appliance in a hot and humid place such as sauna.
Failure to do so may result in product malfunction.
Keep about 2m distance from other electric appliances such as TV, video, audio etc.
Failure to do so may result in reduced video quality or noise.
Do not use the appliance within 1m distance of lighting equipment.
Failure to do so may result in appliance discolouration.
FOR CLEANING
WARNING
Do not clean the appliance by spraying water directly onto it. Do not use benzene, thinner or alcohol to clean
the appliance.
Failure to do so may result in discoloration, deformation, damage, electric shock or fire.
Disconnect the power supply and stop the fan operation before cleaning the appliance.
Failure to do so may result in electric shock orre.
AC-M50ANSA Series_IB_EN_33977A(4).indd 5 2013-07-08 오후 6:07:02
6
Name of each part
Side sensor section
(Dust and Odor sensors)
Power plug
Air louver
Automatically operates in Dust or
Deodo mode.
Air outlet
Grip
Digital display and Control panel
Filter box
Air inlet
Opening the side sensor cover
(When cleaning dust and odor sensors)
Put a mini screwdriver or an object with aat or thin end
into the left groove of the sensor cover and pull it toward
you to open the side sensor.
Pulling out filters
Grip the handle part of alter box and pull out the filter in
the arrow direction.
Dust sensor
Odor sensor
Dust collecting filter section
Deodorization filter section
AC-M50ANSA Series_IB_EN_33977A(4).indd 6 2013-07-08 오후 6:07:03
7
Digital display and Control panel
Power button
Contamination level
display
Mode button
Operation mode
display
Virus doctor
button
Virus doctor display
Timer buttonFAN speed button
Fan speed
display
Pre-filter
cleaning alarm reset button
Pre-filter cleaning alarm
display
Timer display
Air contamination level display
Air contamination level indicates the indoor air contamination state detected by the odor
and dust sensors.
Air contamination level will be displayed as 3 stages: blue, orange, and red color
according to the indoor air contamination status. The blue color means the indoor air is
fine, and the red color means the indoor unit is hazy.
Air contamination level display represents the dust level only. So, the indoor air
contamination level on both dust and odor is shown 2 minutes after turning on the air
purifier since the odor sensor is in detecting indoor air contamination level during the initial 2 minutes.
NOTE
AC-M50ANSA Series_IB_EN_33977A(4).indd 7 2013-07-08 오후 6:07:03
8
Check before use
Checking the following information in advance will enable you to use the air purifier more effectively.
Installation condition
Check the following installation requirement.
The installation area should be level, not sloping.
The area near the air inlet and air exhaust should not be blocked.
The area should not be humid, nor have inflammable material nearby.
The appliance should not intrude in the pathway of people.
The appliance should be installed near a power socket.
Check the power plug and socket
Depending on the plug type and voltage, the power plug should be plugged into correct
wall socket.
The correct temperature and humidity for the operation
Indoor temperature: between 0°C~40°C
If you operate the air purifier out of its temperature range, sensor error will occur and it may result in product shut down.
The operation of the air purifier within a big temperature difference will reduce the life of a filter and cause a product
malfunction due to the dew condensation.
Using a filter
The deodorization + DNAlter is packaged with vinyl, remove the vinyl package before operating the air purifier.
Refer to the ‘Changing Deodorization filter for thelter change. ( P 17 )
Product dimensions
Model AC-M50ANSA/505CM Series
Dimension(mm) W×H×D 435 × 607 × 283
Design and product specifications may be changed for product improvement without notice.
AC-M50ANSA Series_IB_EN_33977A(4).indd 8 2013-07-08 오후 6:07:03
9
Auto mode
The optimized Fan speed will be automatically selected depending on the level of indoor air contamination.
When the air purifier is switched off
Press button to start the operation.
The air purifier will be switched on with ‘beep sound and start in Auto mode.
When the air purifier is switched on
Press [Mode] button and select Auto mode.
Each time you press the button, Auto, Dust, Sleep and Deodo mode will be selected in rotation. Press the button until you
select the Auto mode.
Operation status in Auto mode
FAN speed
The initial 2 minutes of operation will generate ( Mid) breeze and then the optimized FAN speed will be
automatically selected depending on the level of indoor air contamination.
When adjusting the FAN speed, the Auto mode will be automatically canceled and the air purifier will operate
according to the selected speed.
Virus Doctor
Virus doctor will be automatically selected.
Press [Virus Doctor] button to cancel the virus doctor function. The virus doctor display will be o.
AC-M50ANSA Series_IB_EN_33977A(4).indd 9 2013-07-08 오후 6:07:04
10
Dust mode
Dust mode of the air purifier will remove fine dust, big dust particles and yellow dust.
1
2
1
Press button to start the operation.
The air purifier will be switched on with ‘beep sound and start in Auto mode.
2
Press [Mode] button and select Dust mode.
Each time you press the button, Auto, Dust, Sleep and Deodo mode will be selected in rotation. Press the button until you
select the Dust mode.
Operation status in Dust mode
FAN speed
The initial 3 minutes of operation will generate ( Turbo) breeze and then the optimized FAN speed that is
suitable for removing fine dust and big dust will be automatically selected.
The FAN speed in dust mode will be automatically adjusted according to the contamination level of the dust
sensor. Even if the contamination level display of the dust sensor is turned to orange or red color, the low level
breeze will be generated if the dust contamination level is low.
When adjusting the FAN speed, the Dust mode will be automatically canceled and the air purifier will operate
according to the selected speed.
Virus Doctor
Virus doctor will be automatically selected.
Press [Virus Doctor] button to cancel the virus doctor function. The virus doctor display will be o.
Air louver
The air louver will rotate automatically and let the FAN out.
AC-M50ANSA Series_IB_EN_33977A(4).indd 10 2013-07-08 오후 6:07:04
11
Sleep mode
Sleep mode will quietly operate the air purifier during your sleep.
1
2
1
Press button to start the operation.
The air purifier will be switched on with ‘beep sound and start in Auto mode.
2
Press [Mode] button and select Sleep mode.
Each time you press the button, Auto, Dust, Sleep and Deodo mode will be selected in rotation. Press the button until you
select the Sleep mode.
The digital display during the Sleep mode
When selecting Sleep mode, only Sleep mode lamp will be on and the other lamps will be o.
When using Timer’ function in Sleep mode, the Timer display will be lit up
NOTE
Operation status in Sleep mode
FAN speed
The quietest FAN speed ( Low) will be selected.
When adjusting the FAN speed, the Sleep mode will be automatically canceled and the air purifier will
operate according to the selected speed.
Virus Doctor
Virus doctor will be automatically selected.
Press [Virus Doctor] button to cancel the virus doctor function. The virus doctor function will be canceled
with beep sound.
AC-M50ANSA Series_IB_EN_33977A(4).indd 11 2013-07-08 오후 6:07:04
12
Deodo mode
Deodo mode will remove the bad smell from food, cigarette, and home.
1
2
1
Press button to start the operation.
The air purifier will be switched on with ‘beep sound and start in Auto mode..
2
Press [Mode] button and select Deodo mode.
Each time you press the button, Auto, Dust, Sleep and Deodo mode will be selected in rotation. Press the button until you
select the Deodo mode.
Operation status in Deodo mode
FAN speed
The initial 3 minutes of operation will generate ( Turbo) breeze and then the optimized FAN speed that is
suitable for removing odor will be automatically selected.
The FAN speed in Deodo mode will be automatically adjusted according to the contamination level of the
odor sensor. Even if the contamination level display of the dust sensor is turned to orange or red color, the low
level breeze will be generated if the odor contamination level is low.
When adjusting the FAN speed, the Deodo mode will be automatically canceled and the air purifier will
operate according to the selected speed.
Virus Doctor
Virus doctor will be automatically selected.
Press [Virus Doctor] button to cancel the virus doctor function. The virus doctor display will be o.
Air louver
The air louver will rotate automatically and let the FAN out.
AC-M50ANSA Series_IB_EN_33977A(4).indd 12 2013-07-08 오후 6:07:04
13
Virus Doctor function
This function is automatically selected when the air purifier is turned on. It inactivates indoor bioaerosols, virus, fungi and
allergens.
Operating Virus Doctor function
Canceling Virus Doctor
Press [Virus Doctor] button.
The virus doctor display will be off with ‘beep’ sound as the virus doctor
function is canceled.
Selecting Virus Doctor function
Press [Virus Doctor] button.
The virus doctor display will be on with ‘beep’ sound as the virus doctor
function is selected.
Timer function
You can turn the air purifier oat your desired time.
The time period of the timer function is from 1hour to 8hours.
Setting Timer function
When the air purifier is switched on.
Press [Timer] button for setting the time to turn off the air purifier.
Each time you press the button, you can set the off time in hourly unit from
1hour to 8hours.
When you want to cancel the off time, press the [Timer] button until you select
the 8hours and press the button one more time.
You can set the off time only when the air purifier is switched on.
NOTE
AC-M50ANSA Series_IB_EN_33977A(4).indd 13 2013-07-08 오후 6:07:05
14
Adjusting FAN speed
You can adjust FAN speed at your desire.
Select the appropriate Fan speed depending on your indoor environment.
Adjusting FAN speed
Press [Speed] button and select the FAN speed you want.
Each time you press the button, Low( ), Mid( ), High( ) and Turbo( ) will
be selected in rotation.
Press the button until you select the desired FAN speed.
Operation status when adjusting FAN speed
FAN speed
The selected FAN speed will operate.
When pressing [Mode] button, the selected FAN speed will be canceled and the air purifier will operate
according to the selected mode.
Virus Doctor
Virus doctor will be automatically selected.
Press [Virus Doctor] button one time to cancel the virus doctor function. The virus doctor display will be off.
AC-M50ANSA Series_IB_EN_33977A(4).indd 14 2013-07-08 오후 6:07:05
15
Benecial tips
The following tips will be beneficial for your energy saving.
For installation
Do not install the air purifier in an area exposed to sun light and near a heating
appliance.
When the air purifier is exposed to sun light, draw the curtains.
When a heating machine is around the air purifier, move it away from the air
purifier.
For operation
It is preferable to close a window or door during operation.
Operating the air purifier with window or door opened will reduce the
purifying efficiency.
Other information
Make sure you insert the filter for operation and replace the filter when it
generates strange smell.
The purifying function will not work when operating the air purifier without
a filter.
When thelter gets dirty, the purifying efficiency will be reduced. When the
exterior of the filter gets too dirty, thelter generates bad smell, or the air
volume is lessen drastically, thelter should be replaced.
It is preferable not to use the air purifier when strong food smells such as
broiled fish are generated during cooking.
Strong food smells from cooking while operating the air purifier will drastically
decrease the life of Deodorization filter. In a serious case, the odor would be
permeated into the Deodorizationlter and it would produce odor during
operation even after ventilation.
When the surrounding smell permeates into the Deodorizationlter and
it generates bad smell while operating the air purifier, it indicates the
Deodorization filter needs to be replaced.
To close the air louver, you should press button.
Press the when closing the air louver.
If you close the air louver with your hands, they might not be closed
completely..
AC-M50ANSA Series_IB_EN_33977A(4).indd 15 2013-07-08 오후 6:07:05
16
Cleaning and maintenance
Before you clean the air purifier, you must stop the operation and unplug the air purifier.
Cleaning the exterior
Saturate the provided cleaning only towel with warm water and wring the towel
tightly. Then wipe the air purifier with the towel.
Especially, dust might pile up around the air inlet of the air purifier, so please clean
the area frequently.
Do not clean the digital display and control panel with alkaline
detergent.
Do not use acid, acetone or organic solvent(Kerosene, Thinner, etc.) to
clean the surface and do not attach any stickers. They may damage
the surface of the appliance.
When wiping the surface of the air purifier with coarse cloth or rag,
fine scratch might be on the surface of the air purifier. Therefore, you
should use a soft cloth.
CAUTION
Air inlet
Cleaning sensor section
Sensor section is composed of the dust sensor and odor sensor. The dust sensor
detects the contamination level of fine dust or big dust particle and the odor
sensor detects the contamination level of general odors of home such as food
and cigarette smells. The lens of the dust sensor should be cleaned periodically to
maintain its performance efficiency.
1 . Open the side sensor cover.
Open the side sensor cover using a mini screwdriver or an object withat or
thin end.
2 . Clean the dust sensor lens with a cotton bud and remove the dust around
the odor sensor.
Except for water, do not clean the sensor section with volatile matter
such as alcohol and benzene.
When removing dust from the dust sensor, do not wipe othe dust
sensor grid.
When foreign matter(dust) remains around the dust sensor lens, the
contamination level status might not be changed from contamination
status. In that case, clean the sensor again.
CAUTION
3 . Close the side sensor.
Put the side sensor cover into the left side groove and push it in the arrow
direction.
You can conveniently clean the sensor section with a vacuum cleaner
with the side sensor closed.
Clean the sensor section every six months. However, the cleaning
period can vary according to the surrounding environment and hours
of usage, so the period should be shorter in a dusty environment.
NOTE
Dust sensor
Odor sensor
Dust sensor lens
Odor sensor net
Side sensor
section
Side sensor
section
Vacuum cleaner
AC-M50ANSA Series_IB_EN_33977A(4).indd 16 2013-07-08 오후 6:07:06
17
Replacing Deodorization filter section
Deodorization + DNA filter is a high performance filter that removes not only the
harmful smells generated by furniture, wall paper, adhesives but also general odor.
When replacing the Deodorization filter, follow the procedure below.
1 . Pull out the Deodorization filter after opening the filter box.
2 . Widen each side of the filter frame with hands and pull out the
deodorization + DNA filter from filter frame.
3 . Put the new deodorization + DNAlter into the filter frame.
4 . After closing the filter box door, plug in the air purifier.
Clean the pre-filter with running water when the filter cleaning alarm
display on the control panel is lit up.
After cleaning the pre-filter with water, dry it completely and put it in
again. (The dry time of the filter might be different depending on the
seasons.)
After cleaning the pre-filter, press the [Reset] button on the control
panel for more than 2 seconds. The filter cleaning alarm display on the
control panel will be owith the ‘beep sound. When the filter needs to
be cleaned, thelter cleaning alarm display will be lit up again.
Sometimes, pre-filter cleaning alarm display might not be lit up
depending on the surrounding environment. However, you should
press [Reset] button for more than 2seconds whenever younish
cleaning thelter.
Lift up the pre-filter at the groove on thelter section handle(1), and
pull it out in the arrow direction(2).
Changing the deodorization + DNAlter once a year is recommended.
However, thelter replacement period may be different depending on
the indoor air contamination level and hours of usage. Therefore, when
the strange smell is generated from the filter, purchase a new filter at a
service center or a retail store and replace it.
NOTE
Deodorization
filter section
Deodorization filter
Pre-filter
AC-M50ANSA Series_IB_EN_33977A(4).indd 17 2013-07-08 오후 6:07:07
18
Cleaning and maintenance
Replacing Dust collecting filter section
Dust collecting filter section is a high performancelter that is equipped to
improve the performance of dust collecting function. When replacing the Dust
collectinglter, please follow the procedure below.
1 . Open thelter box and pull out the Dust collectinglter section.
2 . Widen each side of the filter frame with hands and pull out the Dust
collectinglter from thelter frame.
3 . Put the new Dust collecting filter into the filter frame.
4 . After closing the filter box door, plug in the air purifier.
Changing Dust collecting filter every one or two year is
recommended. However, filter replacement period might be different
depending on the indoor air contamination level and hours of usage.
Therefore, when the filter gets too dirty, generates strange smell, or
the air volume of the air purifier is reduced drastically, purchase a new
filter at a service center or a retail store and replace it.
NOTE
Dust collecting
filter section
Dust collecting
filter
AC-M50ANSA Series_IB_EN_33977A(4).indd 18 2013-07-08 오후 6:07:07
19
Troubleshooting
Before reporting the problems of your air purifier, please check the below trouble shooting table.
Problem Solution
The air purifier does
not work at all.
Check whether there is a power failure. After checking the status of power supply,
operate the air purifier again.
Check that the power plug is properly connected. Insert the power plug into the
wall socket correctly and operate the air purifier again.
Check the power socket and use another socket.
Check whether the filter box door is open. If the filter box is open, the air purifier
will not operate.
Check whether the [ ] is shown on the off time display of the air purifier. If so, it
means the air purifier has a problem and you should contact a service center.
Air louver does not operate
Check whether you select Auto/Sleep mode or you press [Speed] button. In this
condition, the air louver does not operate. If you want to operate the air louver,
press [Mode] button and operate the air purifier in Dust / Deodo mode.
Odor is generated.
Check whether there is heavy smoke or severe unpleasant odor which may
decrease the air purifying capacity. Ventilate your home and operate the air
purifier again.
Check whether the strange smell is generated from deodorization + DNAlter
and replace the deodorization + DNA filter.
Check whether the strange smell is generated from Dust collecting filter and
replace the Dust collecting filter.
The air contamination level
or virus doctor display on the
control panel is not lit up.
Check whether you have selected Sleep mode. When the air purifier is in Sleep
mode, the air contamination level and virus doctor display will be automatically
off. Therefore, do not worry about the product malfunction with this
Pre-filter cleaning alarm is on
continuously.
Check whether you press [Reset] button after cleaning the pre-filter. After you
clean the pre-filter, you should press [Reset] button for more than 2 seconds.
Air contamination level is
suddenly turned to orange
or red color during the
operation of a humidifier and
air purifier at the same time.
Check whether the humidifier is operating near the air purifier. The fine vapor
particle from a humidifier might be attached to surface of the sensor and this
makes the contamination level display orange or red color. Therefore, do not
worry about the product malfunction with this.
(Leave proper space between the humidifier and the air purifier so that the vapor
particle of the humidifier will not go into the sensor of the air purifier.)
AC-M50ANSA Series_IB_EN_33977A(4).indd 19 2013-07-08 오후 6:07:07
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Samsung AC-M50ANSA/DU User manual

Category
Air purifiers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI