PERRIN ROWE 9.20410 User guide

Type
User guide
IONIAN 2 HOLE MIXERS
The Traditional Kitchen Collection
Installation & User Guide
GUARANTEE & LIABILITY
Your Perrin & Rowe product has been manufactured to exacting standards. However, in the unlikely event that
you should experience any defect, the following guarantees will apply:
Your Perrin & Rowe product is guaranteed against any mechanical defect within five years of the date of
purchase. Should a fault occur; a free replacement part will be issued. In the event that this does not resolve
the defect, a replacement product will be supplied.
The surface finish of Perrin & Rowe products are guaranteed for one year from the date of purchase. This is
provided our care and maintenance instructions have been followed and that no scouring or aggressive cleaning
agents have been used.
This does not affect your statutory rights.
For full terms and conditions please contact Perrin & Rowe.
Perrin & Rowe products are manufactured in the UK, using the latest
technology and built to the highest quality standards.
We would like to thank you for purchasing a Perrin & Rowe product and
take this opportunity to invite you to look at other luxury products by
us. Please contact us to recieve our latest catalogue.
SPARE PARTS & SERVICE
Phone: +44 (0) 1708 526361
Fax: +44 (0) 1708 550220
www.perrinandrowe.co.uk
Perrin & Rowe is a registered trademark of Avilion Ltd. 904172 Issue 2
Temp Range:
Min 1°C/34°F
Max 85°C/185°F
Recommended
Working Pressure:
Max Rinse & Non-Rinse 5bar/75psi
Min Rinse 1bar/15psi
Min Non-Rinse 0.2bar/3psi
For the Rinse version ideal performance obtained with equal hot & cold pressures.
Hose
Length
1200mm
• 4192 • 4193
• 4195 • 4196
• 4172 • 4173
* Where indicated please specify colour
SPARES
HOT
IN
COLD
IN
200Centres
1G /2"
25mm Hole
30mm
Hole
40 mm
Max
140-260 Centres
1G /2"
25mm
Hole
40 mm
Max
1G /2"
25mm Hole
• 4182 • 4183
50 mm Max
9.17384*
9.25384
9.20360*
9.13362
9.13146
9.02174
9.19426
9.01425*
Rinse Seal Kit
9.54755
9.28426
9.03727
9.03865
9.21452*/Red
9.21452*/Blue
9.18192*
9.13145
Mixer Service Kit
9.54719
9.17411*
9.25300
9.20320*
9.17411*
9.25300
9.03182
9.03192
9.20410*
9.13146
9.51451*/Hot
9.51451*/Cold
200Centres
RINSE
NON-RINSE
NON-
RINSE
Congratulations on the purchase of your Perrin & Rowe Kitchen Product. Correctly installed and with sensible
care, this product will give you many years of trouble free service.
The Traditional Kitchen Collection
Installation & User Guide
IMPORTANT INFORMATION
Before you proceed... We recommend you engage the services of a registered plumber to
install this product.
For ease of possible future servicing, we also recommend the fitting of conveniently placed
isolating valves.
In addition to the guide below it is essential that the written information overleaf is carefully
read and understood.
Preparation Check Box for Installer
Flush the plumbing system before
installing the kitchen product.
Once unpacked remove Fibre Washer, Plastic
Backnut and Rinse Connector ready for installation.
1Ensure the mixer is orientated correctly,
levers should rotate to point forward and
hot index should be situated on the left.
Secure mixer with a suitable tap wrench
or a 26 AF Spanner.
The kitchen tap with rinse is supplied with
a brass tube protruding out of the bottom
of the shank. Please be careful not to
damage the end of this tube during
installation.
If your mixer has a rinse please follow
steps 2,3 & 4 to install correctly,
otherwise please connect Hot & Cold
water supplies to shanks.
Ensure all connections are firmly
tightened
4
Please Note: Ceramic disc valves are fitted
as standard to this mixer. Flow from FULLY
OFF to FULLY ON is achieved by rotating the
handles a quarter turn.
32
CARE & MAINTENANCE
Wipe down after use to avoid water spotting and mineral build up.
Occasional cleaning with warm soapy water, followed by a polish with a soft cloth is all that is required to keep
the plated finish in good condition.
Do not use proprietary abrasive liquids, powders, or pads to clean the shower. Do not use any
products with ammonia bleach or limescale remover. You will damage the plated finish and void
your guarantee.
BEFORE USE
• Carefully check the installation for leaks.
• If further building work is to be carried out in the vicinity, cover the tap with a plastic bag to avoid damaging
the finish.
• Please ensure that the installation complies with the water supply bye-laws.
Secure rinse unit
socket in a
suitable position
using a tap
wrench or a 36
AF spanner.
Place flexible
hose through top
of rinse unit
socket as shown
in diagram.
Ensure black rubber
washers are situated
inside position A and B
on the rinse connector.
Screw rinse connector
onto end of flexible
hose.
Ensure connection is
firmly tightened.
Important - Do not cut brass tube.
Carefully feed the rinse connector
over the protruding brass tube and
secure tightly onto the shank.
Ensure black rubber washer is in place
before securing rinse to flexible hose.
Holding the rinse, screw the flexible
hose onto the end of rinse and place
into rinse unit socket. Make sure
orientation of rinse is correct.
The double check valves should be
connected to the incoming hot & cold
supplies. Suitable connections should
then be made to the mixer inlets.
Connect Hot & Cold water supplies to
shanks.
Ensure all connections are firmly
tightened.
WORK SURFACE
Backnut
Base Seal
Base Ring
Work Surface
Backnut
WORK SURFACE
WORK SURFACE
Base Seal
Rinse Unit
Socket
Fibre Washer
Backnut
Flexible Hose
WORK SURFACE
Rinse
Black Rubber
Washer
Flexible
Hose
Shank
Brass Tube
Rinse
Connector
Double Check
Valve
COLDHOT
15mm
15mm
A
B
3G /8"
Rinse
Connector
Deck
Mounted
Wall
Mounted
Rinse Unit