AGI STX2/STX Auger Work Light Kit Installation guide

Type
Installation guide

AGI STX2/STX Auger Work Light Kit

The AGI STX2/STX Auger Work Light Kit is a comprehensive lighting solution designed to enhance visibility and safety during auger operation. It includes a flood lamp for illuminating the discharge area, two mini-flood lamps for the engine and intake areas, a wiring harness, a fused light switch box, cable ties, P-clamps, mounting brackets, and hardware. The kit is compatible with STX2/XTA/R Series augers and provides ample illumination for various work scenarios.

Key Features:

  • Robust construction for harsh agricultural environments
  • Flood and mini-flood lamps for optimal brightness and coverage

AGI STX2/STX Auger Work Light Kit

The AGI STX2/STX Auger Work Light Kit is a comprehensive lighting solution designed to enhance visibility and safety during auger operation. It includes a flood lamp for illuminating the discharge area, two mini-flood lamps for the engine and intake areas, a wiring harness, a fused light switch box, cable ties, P-clamps, mounting brackets, and hardware. The kit is compatible with STX2/XTA/R Series augers and provides ample illumination for various work scenarios.

Key Features:

  • Robust construction for harsh agricultural environments
  • Flood and mini-flood lamps for optimal brightness and coverage
PART NUMBER: 30981 R6
REVISED: 22/2/19
Westfield| Wheatheart
part of the Ag Growth International group
P.O. Box 39, Rosenort, Manitoba, Canada R0G 1W0 Ph: (866) 467-7207 Fax: (866) 768-4852
Website: www.grainaugers.com | www.wheatheart.com Email: [email protected] |[email protected]
© Ag Growth International Inc. 2019
The lighting kit consists of one flood lamp, two mini-flood lamps, a wiring harness, a
fused light switch box, cable ties, cable P-clamps, mounting brackets, and hardware.
1. Install the discharge-area lamp:
attach the flood lamp to the track stop with a bolt, washer, and locknut, then
plug the wiring harness connector into the flood lamp connector. Ensure that
the connectors are fully engaged.
2. Run the wiring harness down the tube to the location of the engine-area lamp.
STX2/XTA Series: Travel through the opening in the bearing brackets.
STX/R Series: Travel along the driveshaft guards and fasten it to the guard
straps with P-clamps using the existing strap screws.
3. Install the engine-area lamp:
31/36/41 models: attach a lamp bracket to the tube weldment above the
engine with a 7/16" x 1" bolt and locknut;
46/51 models:
attach a lamp bracket to the tube flange using existing hardware;
attach a mini flood lamp to the bracket using a bolt, washer, and locknut, then
plug the wiring harness connector into the mini flood lamp connector. Ensure
that the connectors are fully engaged.
4. Install the intake-area lamp:
run the wiring harness down the tube to the gearbox, fastening it as previously
explained;
secure the remaining lamp bracket to the gearbox: for 8" models, use a 3/8" x
1" bolt and lockwasher; for 10" models, use a 1/2" x 1" bolt and lockwasher;
attach the second mini flood lamp to the bracket using a bolt, washer, and
locknut, then plug the wiring harness connector into the mini flood lamp
connector. Ensure that the connectors are fully engaged.
5. Run the wiring harness down the lower frame to the engine.
STX2/XTA Series: Secure using P-clamps and Tek screws.
STX/R Series: Secure using cable ties as required.
6. Connect the wiring-harness eyelet (white wire) to the motor frame (ground).
Connect the butt splice to the motor power (positive).
Note: If no motor power lead is available to connect the butt splice it may be necessary to
use the provided tap splice connector to draw power from another power or accessory
wire. Ensure all connections are fused appropriately.
7. Install the switch box to the lower frame arm with two #8 x 3/4" Tek screws.
STX2/STX/XTA/R SERIES AUGER LIGHTING KIT [A317/A318]
INSTALLATION INSTRUCTIONS
2
Figure 1 STX/R Series
Figure 2 STX2/XTA Series
INTAKE AREA
(MINI FLOOD LAMP)
ENGINE AREA, 36/41 MODELS
(MINI FLOOD LAMP)
ENGINE AREA, 46/51 MODELS
(MINI FLOOD LAMP)
DISCHARGE AREA
(FLOOD LAMP)
INTAKE AREA
(MINI FLOOD LAMP)
ENGINE AREA, 46/51 MODELS
(MINI FLOOD LAMP)
DISCHARGE AREA
(FLOOD LAMP)
ENGINE AREA, 31/36/41 MODELS
(MINI FLOOD LAMP)
  • Page 1 1
  • Page 2 2

AGI STX2/STX Auger Work Light Kit Installation guide

Type
Installation guide

AGI STX2/STX Auger Work Light Kit

The AGI STX2/STX Auger Work Light Kit is a comprehensive lighting solution designed to enhance visibility and safety during auger operation. It includes a flood lamp for illuminating the discharge area, two mini-flood lamps for the engine and intake areas, a wiring harness, a fused light switch box, cable ties, P-clamps, mounting brackets, and hardware. The kit is compatible with STX2/XTA/R Series augers and provides ample illumination for various work scenarios.

Key Features:

  • Robust construction for harsh agricultural environments
  • Flood and mini-flood lamps for optimal brightness and coverage

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI