5
Instruction CF-MC Master Controller
VI.UN.A1.52
Produced by Danfoss Floor Heating Hydronics 09.2005
Instruction CF-MC Master Controller
5
2.2 Resetting the Room Thermostats, CF-RS, -RP, -RD and -RF – g 2:
• Remove the Room Thermostat from the back plate and disconnect
one of the batteries
• Press and hold the push button (Link test) and reconnect the
battery
• Release the push button when the red LED has been On and O
again
• The Room Thermostat is now Reset and ready for installation to a
Master Controller, CF-MC
2.3 Resetting the Remote Controller, CF-RC – g 3:
• At the same time, activate the Soft key 1 , the soft key 2 and the
down selector
• The Remote Controller requests conrmation before resetting.
Conrmation with “yes” Resets the Remote Controller
• By conrming Reset with “yes” the Remote Controller is now ready for
installation to a Master Controller, CF-MC
2.4 Resetting the Repeater Unit, CF-RU – g 4:
• Disconnect the Repeater Unit from the 230V power supply
• Press and hold the push button (Link test) and reconnect the 230V
power supply
• Release the push button when the red LED has been On and O
again
• The Repeater Unit is now Reset and ready for installation to a
Master Controller, CF-MC