14
Dome Functions
<OTHER>
PARK MODE: After an idle period of time has elapsed which is set in
the next parameter (Park Time), the camera will perform the
action which is selected here. The options are: NONE, Pattern 1,
Tour 1, 360 Scan, A/B Scan or Presets 1 thru 8.
PARK TIME: This is the amount of time (in minutes) which the
camera will wait after receiving the last manual PTZ command.
After this time has elapsed, the camera will perform the function
set in the PARK MODE parameter above.
NOTE: The alarms functions are not supported on this model of
camera. Although the alarm menu can be accessed and settings
can be made, they will have no effect on the camera, as there
are no physical alarm inputs or outputs.
<IR>
IR MODE: This sets how the IR LEDs are enabled. AUTO is the
default setting. Auto allows the camera to operate the IR LEDs
as lighting conditions need it, in conjunction with the
ILLUMINATION ON and IR SWITCH ZOOM settings as
described below.
OUTPUT POWER: This determines the maximum brightness of the
LEDs when they are on. Power can be set from 1 thru 9.
TESTING TIME: This determines how long the ambient light level
must remain below the ILLUMINATION ON threshold before the
camera will switch to IR mode. Choose from 2 to 15 seconds.
STANDBY POWER: Allows the user to set a lower-power usage level
for the IR LEDs which engages when the camera sits idle for the
time which is set in the STANDBY TIME parameter below.
Choose from power levels 1 thru 9.
STANDBY TIME: This is how long (in seconds) the camera must sit
idle before switching the IR LEDs into STANDBY POWER
mode, as set above.
ILLUMINATION ON: This setting determines at what ambient light
level the IR LEDs will turn on and the camera will switch to night
mode. When the IR mode is set to AUTO, this setting determines
the brightness level at which the camera will switch from day to
night and vice versa.
IR SWITCH ZOOM: This determines the lens zoom level at which the
camera will change the IR LEDs from “close-up” lighting mode to
“distance” lighting mode.
<OTHER>
PARK MODE NONE
PARK TIME 05
POWER ON ACT MEMORY
RATIO SPEED ON
AUTO FLIP ON
EXIT
<IR>
IR MODE AUTO
OUTPUT POWER 9
TESTING TIME 08s
STANDBY POWER 8
STANDBY TIME 20s
ILLUMINATION ON 05L
IR SWITCH ZOOM 07
AMBIENT LIGHT 06
EXIT