  • Hello! I am an AI chatbot trained to assist you with the ESAB EPP-450 Plasma Power Source User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
0558007961 06/2012
Fuente de alimentación
Manual de instrucciones – ES
EPP-450
4
11
APARTADO 3 INSTALACIÓN
3.1 General
EL INCUMPLIMIENTO DE LAS INSTRUCCIONES CORRESPONDIENTES
PODRÍA OCASIONAR MUERTES, LESIONES O DOS A LA PROPIEDAD.
CUMPLA ESTAS INSTRUCCIONES PARA EVITAR LESIONES O DAÑOS A
LA PROPIEDAD. DEBE RESPETAR TODAS LAS NORMAS ELÉCTRICAS
LOCALES, ESTATALES Y REGLAMENTOS DE SEGURIDAD.
ADVERTENCIA
3.2 Desembalaje
La utilización de una argolla elevadora dañará la lámina y la estructura
de metal. Emplee dos argollas elevadoras cuando lo transporte con
cualquier método que lo eleve en el aire.
CAUTION
• Inspeccione el equipo en busca de daños por transporte inmediatamente después de recibirlo.
• Separe todas las piezas del contenedor de transporte y compruebe que el contenedor no tenga
piezas sueltas.
• Inspeccione los respiraderos de aire en busca de obstrucciones.
3.3 Ubicación
Nota:
Emplee dos argollas elevadoras cuando lo transporte elevándolo en el aire.
• Debe dejarse un mínimo de un metro de separación entre las partes frontal o trasera para permitir el
ujo de aire de refrigeración.
• Prevea el hecho de que los paneles superior y laterales puedan tener que retirarse para mantenimiento,
limpieza e inspección.
• Ubique el EPP-450 relativamente cerca de una fuente de alimentación eléctrica con los fusibles
adecuados.
• Mantenga una zona libre debajo de la fuente de alimentación para permitir el ujo de aire de
refrigeración.
• El ambiente debe estar relativamente libre de polvo, humos o calor excesivo. Estos factores podrían
afectar a la eciencia de la refrigeración.
El polvo y la suciedad conductores en el interior de la fuente de
alimentación podrían causar una combustión súbita generalizada.
Podrían tener lugar daños en el equipo. Puede tener lugar un corto-
circuito si se acumula el polvo dentro de la fuente de alimentación.
Véase la sección de mantenimiento.
CUIDADO
CUIDADO
15
APARTADO 3 INSTALACIÓN
Abra el panel de acceso
Se pueden conectar dos EPP-450 fuentes de alimentación en paralelo para ampliar el rango de salida de corriente.
3.6 Instalación paralela
CUIDADO
Utilice solamente una fuente de alimentación para cortar por debajo
de 100A.
Recomendamos que se desconecte el cable negativo de la fuente
de alimentación suplementaria cuando se cambie a corrientes por
debajo de 100A. Este cable debe aislarse en total seguridad para
proteger contra descargas eléctricas.
Fuente de alimentación
arco piloto
* Cables positivos a
la pieza de trabajo
2 - 2/0 AWG 600V
1 - 14 AWG 600V
Conexión del cable al
arco piloto en la caja
de arranque en arco
(generador alta frec.)
EPP-450
trabajo
(+)
electrodo
(-)
* Se recomienda la utilización de dos cables 2/0 AWG
paralelos para 450A de 100% del ciclo de servicio.
Para el funcionamiento a 400A o menos del 100% del
ciclo de servicio, debe utilizarse un cable 4/0. Además,
para el funcionamiento a 80% del ciclo de servicio
o menos, debe utilizarse un cable 4/0. Un ciclo de
servicio máximo al 80% hace referencia a un máximo
de 8 minutos en cualquier intervalo de tiempo de
10 minutos.
* Cables negativos
a la pieza de trabajo
(generador de alta
frec.) 2 - 2/0 AWG
600V
17
APARTADO 3 INSTALACIÓN
Las conexiones que se detallan a continuación son adecuadas para un funcionamiento en paralelo de hasta
800A al 100% del ciclo de servicio ó 900A o menos del 80% del ciclo de servicio. Un ciclo de servicio al 80% hace
referencia a 8 minutos de arco “activado” en cualquier intervalo de tiempo de 10 minutos.
Fuente de alimentación
suplementaria
Fuente de alimentación
principal
trabajo
(+)
electrodo
(-)
arco piloto
Cables positivos
a la pieza de trabajo
3 - 2/0 AWG 600V
1 - 14 AWG 600V
Conexión del cable al
arco piloto en la caja
de arranque en arco
(generador alta frec.)
3 - 2/0 AWG 600V
Cables negativos en
la caja de arranque
en arco (generador
alta frec.)
EPP-450 EPP-450
trabajo
(+)
electrodo
(-)
Pinzamientos de cables
entre unidades
2/0 AWG 600V
Fuente de alimentación
suplementaria
Fuente de alimentación
principal
trabajo
(+)
electrodo
(-)
arco piloto
Cables positivos
a la pieza de trabajo
2 - 4/0 600V
1 - 14 AWG 600V
Conexión del cable al
arco piloto en la caja
de arranque en arco
(generador alta frec.)
2 - 4/0 600V
Cables negativos en
la caja de arranque
en arco (generador
alta frec.)
EPP-450 EPP-450
trabajo
(+)
electrodo
(-)
Conexiones de la instalación en paralelo de las dos fuentes de alimentación EPP-450 con ambas fuentes de
alimentación en funcionamiento.
Para un funcionamiento con ciclo de servicio al 100% por encima de 800A, consulte el siguiente diagrama
de conexión.
24
P. K. Higgins: Current_Ripple_ESP-600C; RMS CURRENT RIPPLE Chart 17
EPP-600 10/20KHz Output RMS Ripple Current Versus Output Voltage
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
0 50 100 150 200 250 300 350
Output Voltage (Volts)
RMS Ripple Current (Amperes)
Choppers Synchronized and Switchng in Unison (10KHz Ripple)
Choppers Synchronized and Switching Alternately (20KHz Ripple)
APARTADO 4 FUNCIONAMIENTO
4.1 Descripción del circuito de diagrama de bloque (continuación)
El circuito de alimentación utilizado en el EPP-450 normalmente se denomina Convertidor Buck o Reductor. Los conmu-
tadores electrónicos de alta velocidad pasan de activados a desactivados miles de veces por segundo, proporcionando
pulsos de alimentación a la salida. Un circuito de ltro, compuesto principalmente por un inductor (a veces, llamado estran-
gulador), convierte los pulsos en una salida relativamente constante de DC (corriente directa).
Aunque el inductor de ltro elimina la mayoría de las uctuaciones de la salida “reducida” de los conmutadores electró-
nicos, permanecen algunas pequeñas uctuaciones, llamadas ondulación. El EPP-450 utiliza un circuito de alimentación
patentado que combina la salida de dos reductores y cada uno de ellos proporciona la mitad de la salida total, de modo
que se reduce la ondulación. Los reductores están sincronizados, de modo que cuando la ondulación del primer reductor
aumenta la salida, el segundo reductor la disminuye. El resultado es que la ondulación de cada reductor se cancela parcial-
mente con la ondulación del otro. El resultado es una ondulación extra baja con una salida uida y estable. Una ondulación
baja es altamente recomendable porque la vida útil del soplete normalmente se mejora con una ondulación baja.
El gráco a continuación muestra el efecto de la reducción de la ondulación patentada por ESAB mediante dos reductores
sincronizados y conmutado de manera alterna. En comparación con dos reductores que funcionen simultáneamente, la
conmutación alterna normalmente reduce la ondulación en un factor de 4 a 10.
Salida del EPP-450 de 10/20 KHz con corriente ondulatoria RMS
frente al voltaje de salida
Corriente ondulatoria RMS (Amperios)
Voltaje de salida (Voltios)
Reductores sincronizados y conmutado simultáneamente (ondulación de 10 KHz)
Reductores sincronizados y conmutado alternamente (ondulación de 20 KHz)
31
APARTADO 4 FUNCIONAMIENTO
4.4 Conguración de iniciación del arco
El tiempo para alcanzar la corriente completa puede ajustarse para un arranque suave. Esta característica utiliza una corriente
reducida para arrancar y después gradualmente va aumentando hasta alcanzar una corriente completa. El EPP-450 se envía
de fábrica con el arranque suave activado. La conguración por defecto es la siguiente:
Corriente de arranque mínima . . . . . . . . . . . . . . . . .3A
Corriente de arranque . . . . . . . . . . . . . . . . . . . . . . . . .50% de la corriente de corte
Tiempo para alcanzar la corriente completa . . . .800 mseg
Tiempo de permanencia.......................2 mseg mínimo
Estas funciones temporales pueden desactivarse o ajustarse para satisfacer las exigencias individuales del sistema.
Forma de la onda de la corriente de arranque con
arranque suave DESACTIVADO
Corriente de corte
I
SALIDA
= 50 V
REF
(Alto)
I
SALIDA
= 10 V
REF
(Bajo)
Aprox. 2 mseg de tiempo
de corriente completa
Corriente de salida DC
Tiempo
Forma de la onda de la corriente de arranque con
arranque suave ACTIVADO
Corriente de corte
I
SALIDA
= 50 V
REF
(Alto)
I
SALIDA
= 10 V
REF
(Bajo)
Corriente de
arranque
Tiempo para
alcanzar la
corriente completa
800 mseg
Tiempo
de perma-
nencia
Corriente de salida DC
Tiempo
LAS DESCARGAS ELÉCTRICAS PUEDEN MATAR!
APAGUE LA CON EXIÓN DE L A ALIMENTACIÓN EN L A LÍNEA PAR ED
ANTES DE RETIRAR LAS CUBIERTAS O HACER AJUSTES EN LA
FUENTE DE ALIMENTACIÓN.
ADVERTENCIA
35
SECTION 5 MAINTENANCE
5.1 General
ELECTRIC SHOCK CAN KILL!
SHUT OFF POWER AT THE LINE WALL DISCONNECT BEFORE AT
TEMPTING ANY MAINTENANCE.
WARNING
WARNING
EYE HAZARD WHEN USING COMPRESSED AIR TO CLEAN.
• Wear approved eye protection with side shields when cleaning the
powersource.
• Useonlylowpressureair.
CAUTION
Maintenance On This Equipment Should Only Be Performed By
Trained Personnel.
5.2 Cleaning
Regularlyscheduledcleaningofthepowersourceisrequiredtohelpkeeptheunitrunningtroublefree.Thefrequencyof
cleaningdependsonenvironmentanduse.
1. Turnpoweroatwalldisconnect.
2. Removesidepanels.
3. Uselowpressurecompresseddryair,removedustfromallairpassagesandcomponents.Payparticularattentionto
heatsinksinthefrontoftheunit.Dustinsulates,reducingheatdissipation.Besuretoweareyeprotection.
36
SECTION 5 MAINTENANCE
Air restrictions may cause EPP-450 to over heat.
Thermal Switches may be activated causing interruption of func-
tion.
Do not use air lters on this unit.
Keep air passages clear of dust and other obstructions.
WARNING
CAUTION
5.3 Lubrication
• Someunitsareequippedwithoiltubesonthefans.Thesefansshouldbeoiledafter1yearofser-
vice.
• AllotherEPP-450shavefanmotorsthatarepermanentlylubricatedandrequirenoregularmainte-
nance.
ELECTRIC SHOCK HAZARD!
BE SURE TO REPLACE ANY COVERS REMOVED DURING CLEANING
BEFORE TURNING POWER BACK ON.
37
SECTION 6 TROUBLESHOOTING
6.1 General
ELECTRIC SHOCK CAN KILL!
DO NOT PERMIT UNTRAINED PERSONS TO INSPECT OR REPAIR THIS
EQUIPMENT. ELECTRICAL WORK MUST BE PERFORMED BY AN EXPE
RIENCED ELECTRICIAN.
WARNING
Stop work immediately if power source does not work properly.
Have only trained personnel investigate the cause.
Use only recommended replacement parts.
CAUTION
6.2 Fault Indicators
FaultindicatorsarefoundonthefrontpanelUsedwith
theLEDsonPCB1(locatedbehindthecoverwiththe
EPPlabel)problemscanbediagnosed.
NOTE:
Itis normalfor momentary light-
ing(ashing)ofthefaultindicator
andLED3whenacontactoron”
signalisappliedatthebeginning
ofeachcutstart.
FaultIndicatorusedwith:
LED3-BusRipple
LED4-HighBus
LED5-LowBus
LED7-ArcVoltageSaturation
LED8-ArcVoltageCuto
PowerResetFaultIndicatorusedwith:
LED6-RightOvercurrent
LED9-LeftOvercurrent
LED10-LeftIGBTUnsaturated
LED11-RightIGBTUnsaturated
LED12-Left-12VBiasSupply
LED13-Right-12VBiasSupply
PCB1 Located behind
thispanel.
Front Panel Fault
Indicators
38
SECTION 6 TROUBLESHOOTING
FaultIndicator(FrontPanel)
Illuminateswhenthereareabnormalitiesinthecuttingprocessorwhenthe input
voltagefalls±10%outsidethe normalvalue.Momentaryilluminationisnormal.If
continuouslylit,checkLEDs3,4,5,7,and8onPCB1forfurtherdiagnosis.
38
38
LED3–(yellow)BusRippleFault-Momentarilyilluminatesatthebeginningof
eachcut.Continuouslylitduringsingle-phasingorimbalancedline-to-linevolt-
agesofthethreephaseinputline(ExcessiveRipple).PowerSourceisshutdown.
LED4–(yellow)HighBusFault–Illuminateswheninputlinevoltageistoohigh
forproperoperation(approximately20%abovenominallinevoltagerating).
Powersourceisshutdown.
LED5–(yellow)LowBusFault–Illuminateswheninputline
voltageislowerthan10%belownominallinevoltagerating.
PowerSourceisshutdown.
LED7–(yellow)ArcVoltageSaturationFault–Illuminates
whenthecuttingarcvoltageistoohighandcuttingcurrent
dropsbelowpresetlevel.LEDwillextinguishaftervoltage
decreasesandcurrentrises.
LED8–(yellow)ArcVoltageCutoFault–Illuminateswhen
arcvoltageincreasesoverthepresetvalue.PSisshutdown.
39
SECTION 6 TROUBLESHOOTING
PowerResetFaultIndicator(onfrontpanel)
Illuminateswhenaseriousfaultisdetected.Inputpowermustbedisconnectedfora
least5secondstoclearthisfault.CheckPCB1RedLEDs6,9,10,11,12,and13ifthis
faultisilluminatedforfurtherdiagnosis.
LED6–(red)RightOvercurrentFault–Illuminateswhenthecurrentoutoftheright
sidechopperistoohigh(300amps).Thiscurrentismeasuredbytheright-sidehall
sensor.Thepowersourceisshutdown.
38
LED9–(red)LeftOvercurrentFault–Illuminateswhenthecurrentfromtheleftside
chopperistoohigh(300amps).Measuredbythelefthallsensor.Powersourceis
shutdown.
LED10_(red)LeftIGBTUnsaturatedFault–IlluminateswhenleftIGBTisnotfully
conducting.PS(PS)isshutdown.
LED11–(red)Right IGBTUnsaturatedFault–Illuminates
whenrightIGBTisnotfullyconducting.PowerSource(PS)
isshutdown.
LED12–(red)Left-(neg)12VBiasSupplyFault–Illuminates
whennegative 12Vbiassupply tothe leftsideIGBTgate
drivecircuit(locatedonPWM-driveboardPCB2)ismissing.
PSisshutdown.
LED13–(red)Right–(neg)12VBiasSupplyFault-Illuminateswhennegative12Vbias
supplytotherightsideIGBTgatedrivecircuit(locatedonPWMdriveboardPCB3)is
missing.PSisshutdown.
40
SECTION 6 TROUBLESHOOTING
6.3 Fault Isolation
Manyofthemostcommonproblemsarelistedbysymptom.
6.3.1 Nooutputwithcontactorsignalapplied
6.3.2 Outputlimitedto100A
6.3.3 Fansnotworking
6.3.4 Powernotonorlowvoltage
6.3.5 Faultlightillumination
6.3.6 Torchwon’tre
6.3.7 Fussesblown-F1andF2
6.3.8 Intermittent,interruptedorpartialoperation
6.3.3 Fans Not Working
Problem Possible Cause Action
All4fansdonotrun
Thisisnormalwhennotcutting.
Fans run only when “Contactor On
signalisreceived.
None
1,2or3fansdonotrun.
Broken or disconnected wire in fan
motorcircuit.
Repairwire.
Faultyfan(s) Replacefans
6.3.1 No output with contactor signal applied
Problem Possible Cause Action
Contactor signal is applied,
contactor lamp on front
panelis illuminated,K2and
K3 contactors do not close
andlowbusfaultlight, LED
5illuminates.
External emergency stop (E-stop) is
open.
ConnectisolatedcontactofE-stopswitchtopro-
videconnectionbetweenJ1-EandJ1-F.
E-stopbuttononfrontpanelispushed
in.
TwistandpullouttoresetE-stopcondition.
Powerresetlamponfrontpanelindi-
catesaseriousfaultcondition.
Refertosectionunderfaultlightillumination.
6.3.2 Output limited to 100A
Problem Possible Cause Action
Powersourcewillnotgoover
100A.
Highcurrentrangesignalmissing.
ExternalcontrolshouldconnectJ1-RtoJ1-T.As
analternative,inthepowersource,movethered
wireonTB8-1toTB8-2.
41
6.3.4 Power Not On or LOW Voltage
Problem Possible Cause Action
Powersourceinoperable:
Mainpowerlampiso.
Missing3-phaseinputvoltage
Restoreall 3 phases of input voltage to within
±10%ofnominalline.
Missing1of3-phaseinputvoltage
Restoreall 3 phases of input voltage to within
±10%ofnominalline.
Lowopencircuitvoltage
FuseF3/F4blown ReplaceF3/F4
PilotarcContactor(K4)faulty ReplaceK4
FaultyControlPCB1 ReplaceControlPCB1(P/N
0558038312
)
Problem Possible Cause Action
Faultlightilluminatesattheendof
cutbutgoesoatthestartofthe
next.
Normalconditioncausedwhenter-
minatingthearcbyrunningthetorch
otheworkorthearcbeingattached
toapartthatfallsaway.
Reprogramcuttingprocessto
ensurearcisterminatedonlyby
removingthe“ContactorOnsignal.
LED3–(amber)BusRipple
Imbalanceof3-phaseinputpower
Maintainphasevoltageimbalance
oflessthan5%.
Momentary loss of one phase of
inputpower
Restoreandmaintaininputpower
within±10%nominal
FaultycontrolPCB1 ReplacePCB1P/N
0558038312
LED4–(amber)HighBus
Oneormorephasesofinputvoltage
exceednominallinevoltagebymore
than15%.
Restoreandmaintainlinevoltage
within±10%
FaultycontrolPCB1 ReplacePCB1P/N
0558038312
Oneormoreshorteddioderectiers
(D25-D28)onthe“ElectrodePlate
Replaceshorteddioderectiers
LED5–(amber)LowBus
One or more phases of input volt-
agearelowerthannominalbymore
than15%.
Restoreandmaintainwithin
±10%ofnominal
BlownF1andF2fuses
SeeF1andF2inBlown
FusesSection
OvertempLightcomeson. SeeovertempinFaultLightSection
Imbalanced3-phaseinput
power
Maintainphasevoltageimbalance
oflessthan5%
Momentary loss of one phase of
inputpower
Restoreandmaintainwithin
±10%ofnominal
FaultyMainContactor(K1) ReplaceK1
FAULTYControlPCB1 ReplacePCB1P/N
0558038312
SECTION 6 TROUBLESHOOTING
6.3.5 Fault Light Illumination
42
SECTION 6 TROUBLESHOOTING
Problem Possible Cause Action
LED 6 – (red) Right Over Cur-
rent
Note:
Ifoperationat275Aorlessis
possible,thentheLEFTsideis
notworking.
Cuttingatover275Awithafaultyleftside
(leftsideoutput=0)
Seefaultyleftorrightside
Rightcurrenttransducerconnectorloose
orunplugged.PCBloose.
Secureconnections
Loose or unplugged connector at right
PWM/DrivePrintedcircuitboard.
Secureconnection
P2atleftofPWM/DrivePCBlooseorun-
plugged.
Secureconnection
CheckvoltagebetweenP7-6andP7-7.A
voltage in either polarity of greater than
0.01Vindicatesafaultyrightcurrenttrans-
ducer(TD2).
Replace right current transducer
(TD2)
FaultyPCB1 ReplacePCB1P/N
0558038312
FaultyrightPWM/DrivePCB
Replace right PWM / Drive PCB P/N
0558038324
LED9–(red)LeftOverCurrent
Note:
Ifoperationat275Aorlessis
possible,thentheRightsideis
notworking.
Cuttingatover275Awithafaultyrightside
(rightsideoutput=0)
Seefaultyrightside
Leftcurrenttransducerconnectorlooseor
unplugged.PCBloose.
Secureconnections
LooseorunpluggedconnectoratleftPWM
/DrivePrintedcircuitboard.
Secureconnection
P2 at right of PWM / Drive PCB loose or
unplugged.
Secureconnection
CheckvoltagebetweenP7-2andP7-3.A
voltage in either polarity of greater than
0.01Vindicatesafaultyleftcurrenttrans-
ducer(TD1).
Replaceleftcurrenttransducer(TD1)
FaultyPCB1 ReplacePCB1P/N
0558038312
FaultyleftPWM/DrivePCB
Replace left PWM / Drive PCB P/N
0558038324
NEVER attempt to power-up or operate the power source with any
Gate / Emitter IGBT Plug disconnected from its PWM / Gate Drive
Board. Attempting to operate the power source with any open (un-
plugged) IGBT Gate / Emitter Connector may damage the IGBT and
the plasma cutting torch.
CAUTION
43
SECTION 6 TROUBLESHOOTING
Problem Possible Cause Action
VeryhighOutputcurrentac-
companiedbyeitheraleftor
rightovercurrent(LED6)
ShortedIGBT ReplacetheIGBTs
Currentpotsettoohigh Lowerthecurrentsetting
FaultyleftPWM/DrivePCB ReplaceleftPWM/DrivePCB
Highremotecurrentsignal Decreaseremotecurrentsignal
FaultyPCB1 ReplacePCB1P/N0558038312
LED10-(red)LeftIGBTUn-
saturated
BlackwireconnectingIGBT(Q2)collectortoP3ofthe
leftPWM/DrivePCB(PCB2)isdisconnected.
Secureconnector
ShortedFreewheelingDiode(s) Replacefreewheelingdiode(s)
LooseorunpluggedP1connectorattheleftPWM/
DrivePCB
SecureP1
LooseorunpluggedP10connectoratPCB1 SecureP10
FaultyPCB1 ReplacePCB1P/N0558038312
FaultyleftPWM/DrivePCB ReplacePCB2P/N0558038324
LED 11 - (red) Right IGBT
Unsaturated
BlackwireconnectingIGBT(Q5)collectortoP3ofthe
rightPWM/DrivePCB(PCB3)isdisconnected.
Secureconnector
ShortedFreewheelingDiode(s) Replacefreewheelingdiode(s)
LooseorunpluggedP1connectorattheleftPWM/
DrivePCB
SecureP1
LooseorunpluggedP10connectoratPCB1 SecureP11
FaultyPCB1 ReplacePCB1P/N0558038312
FaultyrightPWM/DrivePCB ReplacePCB3P/N0558038324
44
SECTION 6 TROUBLESHOOTING
Problem Possible Cause Action
LED12–(red)Left–12VMissing
LooseorunpluggedP1connectorat
theleftPWM/DrivePCB
SecureP1connector
Loose or unplugged P10 connector
atPCB1
SecureP10connector
FaultyleftPWM/DrivePCB
Replace left PWM / Drive PCB P/N
0558038324
LED12–(red)Right–12VMissing
LooseorunpluggedP1connectorat
therightPWM/DrivePCB
SecureP1connector
Loose or unplugged P11 connector
atPCB1
SecureP11connector
FaultyrightPWM/DrivePCB
Replace right PWM / Drive PCB P/N
0558038324
VeryhighOutputcurrentaccompa-
niedbyeitheraleftorrightovercur-
rent(LED9orLED6respectively)
ShortedIGBT ReplacetheIGBTs
Currentpotsettoohigh Lowerthecurrentsetting
FaultyleftPWM/DrivePCB
Replace left PWM / Drive PCB P/N
0558038324
Highremotecurrentsignal Decreaseremotecurrentsignal
FaultyPCB1 ReplacePCB1P/N0558038312
OverTempLampilluminates
Oneormorefansinoperable Repairorreplacefan(s)
Brokenwireorunpluggedconnector
atthermalswitch.
Repair brokenwires and unplugged con-
nector
Obstructiontoairowcloserthan3feet
(1m)torearofpowersource.
Allow3ft.(1m)minimumbetweentherear
ofthepowersourceandanyobjectthatmay
restrictairow.
Excessive dirt restricting cooling air
ow
Cleanoutexcessivedirt,especially in the
extrusionsfortheIGBTsandfreewheeling
diodes,thePOS,NEGandElectrodePlates,
the main transformer (T1) and the lter
inductors(L1andL2).
Obstructedairintake
Checkandclearanyobstructionsfromthe
bottom, front, and top rear of the Power
Source.
45
SECTION 6 TROUBLESHOOTING
6.3.6 Torch Will Not Fire
Problem Possible Cause Action
MainArcTransferstothe workwitha
short“pop,placingonlyasmalldimple
inthework.
Remote control removes the start
signalwhenthe main arc transfers to
thework.
Panel/Remoteswitchin“Remote”with
noremotecontrolofthecurrent
Place Panel/Remote switch in“Panel”
position
Remote current control present but
signalmissing.
CheckforcurrentreferencesignalatTB1-
4(+)andTB1-5(-).SeeSignalvs.Output
CurrentCurvethissection.
Currentpotsettoolow. Increasecurrentpotsetting.
Start current pot, located behind the
cover for the control PCB is set too
low.
Increasethestartcurrentpostsetting
to“7”.
Arcdoesnotstart.Thereisnoarcatthe
torch.OpencircuitvoltageisOK.
Openconnectionbetweenthepower
sourcepositiveoutputandthework.
Repairconnection
FuseF6inthePilotarccircuitisblown. ReplaceF6
FuseF7inthepilotarccircuitisblown. ReplaceF7
PilotarcHigh/Lowswitchisinthe”LOW”
positionwhen usingconsumables for
100Aorhigher(Refertoprocessdata
includedintorchmanuals)
Change Pilot arc to“High position.
(Refertoprocessdataincludedintorch
manuals)
Pilotarccontactor(K4)faulty. ReplaceK4
FaultyPCB1
ReplacePCB1P/N
0558038312
46
Problem Possible Cause Action
FusesF1andF2blown.
Processcontrollerignitespilotarctoo
soon after providing the “Contactor
Onsignal
Process controller must allow at least
300MS to lapse between the applica-
tion of the“Contactor On” signal and
theignitionofthepilotarc.Fixprocess
controllerlogicandreplacediodes.
Faultynegative(Electrode)outputcable
shortingtoearthground.
Repaircable
Shortedfreewheelingdiode.
Replace shorted freewheeling diode
andF1-F2
One or more shorted diode rectiers
(D13-D18)on“POSPlate.
Replacealldioderectiersonthe“POS
P l a t e ”.
One or more shorted diode rectiers
(D7-D12)on“NEGPlate.
Replacealldioderectiersonthe“NEG
P l a t e ”.
SECTION 6 TROUBLESHOOTING
6.3.7 Fuses F1 and F2 Blown
Problem Possible Cause Action
WorksOKat275Aorless-Over
current right side when cutting
over275A.LED6oncontrolboard
illuminated.
LooseorunpluggedconnectoratleftPWM/
DrivePCB(PCB2)
Secureconnector
FaultyleftPWM/DrivePCB
Replace right PWM / Drive PCB P/N
0558038324
CheckvoltagebetweenP5-1andP5-2atthe
leftPWM/DrivePCB(PCB2).Shouldbe20V
AC.BetweenP5-1andP5-3shouldbe40VAC.
Ifnotthecontroltransformer(T5)isfaulty.
ReplacecontroltransformerT5
6.3.8 Intermittent, Interrupted or Partial Operation
NEVER attempt to power-up or operate the power source with any
Gate / Emitter IGBT Plug disconnected from its PWM / Gate Drive
Board. Attempting to operate the power source with any open (un-
plugged) IGBT Gate / Emitter Connector may damage the IGBT and
the plasma cutting torch.
CAUTION
WorksOKat275Aorless-Over
current left side when cutting
over275A.LED9oncontrolboard
illuminated.
LooseorunpluggedconnectoratRightPWM
/DrivePCB(PCB3)
Secureconnector
FaultyRightPWM/DrivePCB
Replace right PWM / Drive PCB P/N
0558038324
CheckvoltagebetweenP5-1andP5-2atthe
rightPWM/DrivePCB(PCB3).Shouldbe20V
AC.BetweenP5-1andP5-3shouldbe40VAC.
Ifnotthecontroltransformer(T7)isfaulty.
ReplacecontroltransformerT7
47
SECTION 6 TROUBLESHOOTING
Problem Possible Cause Action
Power Supply turns o prema-
turelyinthemiddleofthecut.
“ContactorOn”signalisremovedfromunit.
PowersourceisOK.Troubleshootpro-
cesscontroller.
Momentarylossofprimaryinputpower.
Restore and maintain input voltage
within±10%ofnominal.
Faulty condition, indicated by illumination
ofthefaultlamp.
RemovecontrolPCB(PCB1)accesspanel
todeterminethefaultcausingtheshut-
down.Refertofaultlightillumination
section.
Faultycondition,indicatedbytheillumination
ofthepowerresetfaultlamp.
RemovecontrolPCB(PCB1)accesspanel
todeterminethefaultcausingtheshut-
down.Refertofaultlightillumination
section.
Currentsettingtoolow. Increasecurrentsetting
Remotecurrentsignalremovedduringcut. Fixremotecurrentsignal
Problem Possible Cause Action
Output current is unstable and
drifts above or below the set-
ting.
PlacethePANEL/REMOTEswitchinthe“PANEL
position.Adjustcurrentcontrolpot.Ifcurrent
nolongerdrifts,theremotecurrentcontrol
signalisfaulty.
Fixtheremotecurrentcontrolsignalto
operatethePANEL/REMOTEswitchin
the“PANELposition.
Select“PANELonthePANEL/REMOTEswitch
andadjustthecurrentcontrolpot.Thecur-
rentstilldrifts,measurethecurrentreference
signalatTB1-4(+)andTB1-5(-).Ifthesignal
drifts,thecurrentcontrolpotisfaulty.Ifthe
signaldoesnotdrift,theControlPCB(PCB1)
isfaulty.
Replacethecurrentcontrolpot.
Replace the control PCB (PCB1) P/N
0558038312
/