CurrentDNSServer2=10.32.60.5
DNSServersfromDHCP=1
RegisterDNSRACName=1
DNSRACName=iDRAC-783932693338
CurrentDNSDomain=us.dell.com
System Information:
SystemModel=PowerEdgeM600
SystemBIOSVersion=0.2.1
BMCFirmwareVersion=0.32
ServiceTag=48192
HostName=dell-x92i38xc2n
OSName=
PowerStatus=OFF
Watchdog Information:
RecoveryAction=None
Presentcountdownvalue=0seconds
Initialcountdownvalue=0seconds
示例
l racadm getsysinfo -A -s
"System Information:"("系统信息") "PowerEdge M600" "0.2.1" "0.32" "48192" "dell-x92i38xc2n" "" "ON"
l racadm getsysinfo -w -s
System Information:
SystemModel=PowerEdgeM600
SystemBIOSVersion=0.2.1
BMCFirmwareVersion=0.32
ServiceTag=48192
HostName=dell-x92i38xc2n
OSName=
PowerStatus=ON
Watchdog Information:
RecoveryAction=None
Presentcountdownvalue=0seconds
Initialcountdownvalue=0seconds
限制
只有 managed server 上装有 Dell OpenManage 时,getsysinfo 输出中的"Hostname"(主机名)和"OS Name"(操作系统名称)字段才会显示准确的信息。如果
managed server 上没有安装 OpenManage,这些字段将会为空白或显示错误的信息。
getractime
表A-10 说明了 getractime 子命令。
表 A-10.getractime
提要
racadm getractime [-d]
说明
如果不带选项,getractime 子命令会以通用可读格式显示时间。
使用 -d 选项时,getractime 会以如下格式显示时间,yyyymmddhhmmss.mmmmmms,这与 UNIX date 命令返回的格式相同。