Cadet FWAP Installation guide

Type
Installation guide
1'(.#61%(75('9,6+$0;/1'(.+($6(4
Any ofthefollowingmodels maybe replacedusingtheFWconversion kit:
FW051, RW051,FW052, RW052, FW071, RW071, FW751,RW071, FW752,RW752
FW072, RW072,FW101, RW101, FW102, RW102, FW121,RW121, FW122,RW122
FW151, RW151,FW152, RW152, FW202, RW202, FW252,RW252, FW302,RW302
*Theabovemodels may be controlled by eithera built-inthermostat or awall mountthermostat.
(0(4$.$)(6;0)14/$6,10
 !
3 Screws
2 Spring Nuts
2 Lead Wires
1 Replacement Grill Label
2 Mounting Screws
1 Conversion Plate
3 Lock Tooth Washers
1 Instruction Guide
!
Phillips Screwdriver
Straight Screwdriver
#
7406+((.(&64,&$.219(41))$66+(
(.(&64,&$. 2$0(. %1$4' &,4&7,6
%4($-(4 14 )75( %1: $0' .1&- 14
6$* 6+( 2$0(. %1$4' '114 61
24(8(0651/(10()41/6740,0*10
219(4 9+,.( ;17 $4( 914-,0* 10
6+(+($6(4 $,.74(61'151&17.'
4(57.6 ,05(4,175(.(&64,&$.5+1&-
%7405142155,%.('($6+
 #
,5-1)),4(142412(46;'$/$*(
< replace your heater with a higher wattage assembly.
Replace  your  heater  with  the  same  voltage  and  wattage  that
was  originally  installed.  Replacing  it  with  a  higher  wattage
heater  could  result  in  an  overloaded  electrical  circuit  in  your
home, which could result in a fire and serious property damage.
Replacing with a lower wattage heater may cause insufficient
heat and result in increased energy costs.
 All electrical work and materials must comply with the National
Electric Code (NEC), the Occupational Safety and Health Act
(OSHA), and all state and local codes.
 When  installing  the heater  conversion  kit,  be  certain  the  FW
heater being replaced was wired correctly to all electrical codes
and the supply wiring is the correct size and in good condition.
If not, it must be replaced before proceeding.
 If  you  need  to  install  a  new  circuit  or  need  additional  wiring
information, consult a qualified electrician.
 Protect electrical supply from kinks, sharp objects, oil, grease,
hot surfaces or chemicals.
($674(5<<(0(),65
Converts discontinued FW Series wall can
to newer Com-Pak or Com-Pak Max
ULListed for installation of Com-Pak
model into FW wall can
No sheetrock construction necessary -
saves time and money
Vertical or horizontal installation
);17$4(70&1/)146$%.(914-,0*9,6+(.(&64,&$.$22.,$0&(570$%.(61)1..196+(5(*7,'(.,0(5
14'1016+$8(6+(0(&(55$4;(37,2/(06&1057.6$.,&(05('(.(&64,&,$0
vertical installation shown
1
"  ! 
cadetheat.com Tel: 360-693-2505 P.O. Box 1675 Vancouver, WA 98668-1675
©2014 Cadet   Printed in U.S.A.   12/14  #720027
FWAP Conversion Kit
Installation Instructions
http://www.cadetheat.com/products/wall-heaters/com-pak
Spring Nut
(/18,0*.'#($6(4
1.Pulloff thermostat knob(if applicable)and removetop andbottom grill
screws toremove grill.
2.Remove screwonbottom centerofheater assembly.
3.Unscrewinsulatedwire connectors and separatesupply wiresfrom
h
eater wires.
4.Remove theheater assemblybypushingupinthe direction of the fan
and pulling unit out of wall can.
056$..,0*108(45,10,6
1.Screwtop andbottom screws and washers abouthalfwayinto the wall
can with the half-moon tabs facingout (SeeFigure 1).
2.Pushplatedowninto position.
3. Tighten thescrews.NOTE: Star washers MUST belocatedbetween
the screw head andpaintedsurfaceofthe conversion plate.
4.Installone springnut at the top and one at the bottom (SeeFigure 2).
056$..,0*(9($6(455(/%.;
16( If FW heaterwas wired with thesupply circuit entering the wall can
from the top, it may benecessary to add8 inchesof lead wire to each of
thesupply linesbefore proceeding with installationof new heater. 
1. +(1/$-4(37,4(5$6+(4/156$66112(4$6( Please follow
wiring instructionssupplied with eitheryour built-in thermostat kit 
orwallmountthermostat and your new heater. Ifnewheaterhas 
a built-inthermostat, the two mounting screwsmustbe removed
and reattached tothe bottomoftheFWAP.
2.Once wiring is complete, slide heater assemblyintohalf-moon tabs
locatedonbottom ofconversionplate.Use screw suppliedwith heater
assembly andstar washer suppliedwithkittoattach heater to 
conversion plate.
3.Ifusingoriginal grill, turnthe grill upside down(SeeFigure 3) and
installusing two new #10 screws. Ifthereisa built-inthermostat,
besureit isatthe bottom.
4. Affix new label(provided) on invertedgrill. It is notnecessaryto
remove the old label. If using abuilt-in thermostat, cut thermostat
shaft holeout of new label.
2(4$6,1005647&6,105
1. Once installation is completeand power hasbeen restored,turn the
thermostat knobfully clockwise.
2. When theroom reaches your comfort level,turnthe thermostat knob 
counterclockwiseuntilthe heaterturns off. The heaterwill
automat ically cycle aroundthispreset temperature.
3. Toreduce theroom temperature,turn theknob counterclockwise. 
Toincrease the room temperature, turnthe knob clockwise.
#05647&6,105$&-,'(
Spring Nut
+$.)
/110
6$%5
,*74(
,*74(
,*74(