Polycom EF2241 User manual

Type
User manual

This manual is also suitable for

Vortex EF2241
Reference Manual
VORTEX EF2241 REFERENCE MANUAL
Polycom, Inc., Copyright 2002 1 Technical Support: 800.932.2774
Introduction....................................................................................................2
Product Features .................................................................................................... 3
Pre-Installation...............................................................................................5
EF2241 Front and Rear Panels.............................................................................. 6
Installation .....................................................................................................8
Mounting the EF2241 ............................................................................................. 8
Connecting the EF2241 to Other Equipment ......................................................... 8
Device IDs on the EF Bus....................................................................................... 10
Connecting Multiple Vortex Devices ...................................................................... 10
Factory Default Settings (Preset 0) ........................................................................ 11
Check Surrounding Equipment............................................................................... 13
Integrating the EF2241 Into Your System.....................................................15
Input Settings .......................................................................................................... 15
Calibration.............................................................................................................. 15
Set up the Phone Interface...................................................................................... 17
Build Your Echo Canceller Reference.................................................................... 17
Echo Canceller Reference for Multiple Vortex Devices......................................... 17
Configure the Automatic Microphone Mixer.......................................................... 19
Automixer Settings for Multiple Vortex Devices .................................................... 21
Configure the Matrix Mixer.................................................................................... 22
Building Your System with Multiple Vortex Devices.............................................. 22
The EF Bus ....................................................................................................24
Presets..................................................................................................................... 25
Other EF2241 Features.......................................................................................... 25
LCD Menu Structure .....................................................................................26
System Menu ........................................................................................................... 28
Phone Control......................................................................................................... 29
Inputs ...................................................................................................................... 30
Outputs.................................................................................................................... 31
Automixer Menu...................................................................................................... 31
Matrix Menu ........................................................................................................... 34
Parametric EQ Menu.............................................................................................. 35
Presets..................................................................................................................... 36
Macros .................................................................................................................... 36
Troubleshooting .............................................................................................37
Automatic Microphone Mixer................................................................................. 37
Matrix Mixer........................................................................................................... 38
Echo Canceller Reference ...................................................................................... 38
Residual Echo ......................................................................................................... 38
Contacting Technical Support ................................................................................ 43
Technical Specifications ................................................................................44
Compliance............................................................................................................. 45
Conference System Design............................................................................49
EF2241 Block Diagram .................................................................................50
Connector Pinouts..........................................................................................51
Connecting Unbalanced RCA to Balanced Mini Phoenix...................................... 53
Making an EF Bus Terminator............................................................................... 53
Additional Notes ..................................................................................................... 54
Warranty Information ....................................................................................55
Definition of Terms .......................................................................................57
Index ..............................................................................................................60
INTRODUCTION
VORTEX EF2241 Reference Manual 2 Technical Support: 800.932.2774
I
NTRODUCTION
Welcome Congratulations on your purchase of the Vortex EF2241!
How to Use This
Manual
This is a reference manual for your EF2241. It is structured to provide the informa-
tion you need quickly and conveniently. The following is an overview of each sec-
tion:
Introduction
Pre-Installation includes information about the contents of the box, tools needed
for installation and front and rear panel descriptions.
Installation covers connections of inputs/outputs and calibration of inputs of the
EF2241.
Integrating the EF2241 Into Your System describes adjustments to take into con-
sideration when integrating the EF2241 with surrounding equipment in your sys-
tem.
•LCD Menu Structure describes an overview of the LCD menu structure and also
gives a system overview of features and options available.
Troubleshooting helps to debug problems with installation.
Technical Specifications provides the technical specifications of the EF2241.
Conference System Design gives suggestions on topics to consider when design-
ing your system.
EF2241 Block Diagram shows the inside of the EF2241.
Connector Pinouts shows pinout diagrams for EF2241 input and output connec-
tors.
Warranty Information
Definition of Terms explains terms used in this manual, as well as terms used in
our technology of echo cancellation, noise cancellation, and audio conferencing.
About the EF2241 The Vortex EF2241 is a companion to the Vortex EF2280, or a stand-alone solution
for audio conferencing. It automatically mixes four microphones and other audio
while cancelling acoustic echoes and annoying background noise, and features a
built-in “phone add” to bring telephone calls into the conference. A total of 8 Vortex
devices can be linked together (for instance, 8 EF2280s, or 2 EF2241s and 6
EF2280s).
The EF2241 has 4 mic/line inputs, 4 line inputs and 8 line outputs with 4 channels of
acoustic echo and noise cancellation. It has matrix mixing and automatic microphone
mixing capabilities, a single telephone line interface, and a single channel power amp.
It includes a total of 8 analog inputs (4 mic/line level inputs and 4 line level inputs), 8
analog outputs, and 5 digital expansion busses (one being dedicated to phone).
Acoustic echo cancellation (AEC) and noise cancellation can be applied to each of the
4 mic/line level inputs, and each of these inputs can then be sent to one of the two
internal automatic microphone mixers.
The system also contains a 23 x 17 main matrix, four 7 x 3 submatrices, and one 7 x 2
submatrix for transporting audio from the phone line. The 23 x 17 main matrix has
the following inputs: Input channels 1-4 (gated or ungated), Input channels A-D, the
internal signal generator, 3 mixes of each of the four digital busses (3 mixes times 4
INTRODUCTION
© Polycom, Inc. 3 VORTEX EF2241 Reference Manual
busses equals 12 inputs), and 2 mixes of the P Bus for the telephone. The 23 x 17
main matrix has the following outputs: Outputs 1-4 and A-D, AEC Reference 1 and 2,
W, X, Y, and Z outputs to the digital expansion bus, P output to the digital expansion
bus, output to the power amplifier, and output to the phone line. The EF2241 has 24
bit resolution, 32-bit floating point computation, and a 48 kHz sampling rate.
Polycom’s proprietary noise cancellation on each of the 4 mic/line inputs and the tele-
phone line helps to keep overall ambient noise to a minimum. Polycom echo cancel-
lers are the only ones on the market to feature this patented technology. Noise
cancellation filters out ambient background noise such as noise from heating, venti-
lating and air conditioning (HVAC), LCD projectors, and road noise. Our noise can-
cellation technology is not a noise gate. It actually removes noise. Therefore, it
enhances the operation and improves the sound quality of an automixer, for example,
by preventing it from bringing the noise level up and down when microphones are
gated on and off. By cancelling the noise picked up by each microphone, the overall
signal to noise ratio (SNR) is preserved. The result is crystal clear speech over a
greater decibel range than any other echo canceller. That means reduced listener
fatigue and a higher quality audio conference.
Product
Registration
Please take a moment to fill out and return your registration card. This information
will help us to provide you with better customer support and will allow us to notify
you with updated product features and software.
P
RODUCT
F
EATURES
Product Front panel LCD for controlling and configuring the product without a computer
5-band equalizer on all Inputs and Outputs
Echo cancellation on Inputs 1-4
Noise cancellation up to 15 dB
Two internal automatic microphone mixers for Inputs 1-4
23 x 17 full cross point matrix mixer with expansion bus
Internal signal generator for calibration mode and noise masking applications
2 year warranty
AEC 24 bit resolution
48 kHz sampling rate, >20 kHz bandwidth
270 ms AEC tail length
40 dB/sec convergence rate
Can function in rooms with more than 10 dB of room gain
LEC 32 ms LEC tail length
40 dB/sec convergence rate
> 65 dB total cancellation
INTRODUCTION
VORTEX EF2241 Reference Manual 4 Technical Support: 800.932.2774
Inputs and
Outputs
4 microphone/line level inputs with phantom power on each input
24 VDC Phantom Power
4 line level auxiliary inputs with nominal level of 0 dBu
8 line level outputs with default nominal level of 0 dBu
Automatic Gain Control (AGC) on Inputs 1-4.
Remote Control RS-232 port for remote control
Reconfigurable parallel logic input/output
EF bus for linking multiple Vortex devices
Digital bus with 5 audio busses, 48 kHz sampling rate
Up to 8 Vortex devices can be linked, each device providing 4 audio signals on
the bus and each EF2241 providing 1 phone audio signal on the bus
PRE-INSTALLATION
© Polycom, Inc. 5 VORTEX EF2241 Reference Manual
P
RE
-I
NSTALLATION
What’s Included The Vortex EF2241 product package includes the following items:
Vortex EF2241 Reference Manual
Vortex EF2241
External power supply
Cat 5 cable for EF Bus
Telephone cable
Rack mount screws (4)
Phoenix connectors (16)
Cable clamp and screw
CDROM containing other manuals and Conference Composer software
Product Registration Card
What’s Not
Included
The following equipment is not included with the EF2241 product package, but may
be necessary to create a completely functional system:
Microphones
Loudspeakers
Audio cables
Videoconferencing codec or other four-wire interface (optional)
RS-232 remote control device (optional)
Tools Needed for
Installation
Screwdriver to mount the EF2241 in your rack.
Phoenix connector screwdriver
Figure 1. What’s Included with your Vortex EF2241.
x
x
x
x
Vortex
®
EF2241
Rackmount
Screws (4)
Cable Clamp
and screw
CDROM with
control software and manuals
External
Power Supply
Vortex EF2241 Reference Manual
Vortex
®
EF2241
Reference Manual
Phoenix
Connectors (16)
1-Cat 5 cable
for EF
Bus
1-Telephone cable
PRE-INSTALLATION
VORTEX EF2241 Reference Manual 6 Technical Support: 800.932.2774
EF2241 F
RONT
AND
R
EAR
P
ANELS
1. LCD DISPLAY. Displays menu instructions for configuration and operation of the
EF2241.
2. D
OWN BUTTON. Scrolls backward through menu items at a particular level or
decreases the value of a parameter.
3. U
P BUTTON. Scrolls forward through menu items at a particular level or increases
the value of a parameter.
4. E
NTER. Enters the menu and allows you to select and change parameter values.
5. E
SC. Returns to the next highest level of menus.
6. H
OME. Returns to the top of the menu structure.
7. L
EVEL INDICATOR. Indicates the level of the selected channel or parameter.
8. P
HONE CONNECT. Takes the phone line on or off hook. If you have an analog
handset connected to the P
HONE jack on the back panel, pushing this button will
disable the P
HONE jack while enabling the LINE jack (see Item 17).
9. C
HANNEL ACTIVITY LEDS. Indicates gating activity of the 4 mic/line channel
inputs.
Figure 2. EF2241 Front and Rear Panels
3 4 5612 7 9
11 1310 12 14 15
16
18
20
17
19
8
PRE-INSTALLATION
© Polycom, Inc. 7 VORTEX EF2241 Reference Manual
10. INPUT PARALLEL PORT. Parallel logic input.
11. O
UTPUT PARALLEL PORT. Parallel logic output.
12. EF B
US IN. Connects to EF BUS OUT of another Vortex device.
13. EF B
US OUT. Connects to the EF BUS IN of another Vortex device.
14. RS-232 S
ERIAL PORT. Connect this to an optional RS-232 remote control device,
such as a touch panel or personal computer COM port.
15. P
OWER SUPPLY INPUT. Connects to the external power supply provided with the
EF2241.
16. P
OWER AMPLIFIER OUTPUT. Drives up to 10 W into 4-16 Ohm speakers.
17. P
HONE/LINE JACKS. Use the PHONE jack for connecting an analog handset to the
system. Use the L
INE jack for connecting to an analog telephone line.
18. M
IC/LINE INPUTS. Connects to microphone at either mic or line level, with or
without phantom power.
19. L
INE INPUTS. Inputs A-D at line level.
20. L
INE OUTPUTS. Outputs 1-4 and Outputs A-D at line level.
Figure 3. Parallel remote control, EF B
US, serial remote control, power supply
input, and power amplifier output on back panel of the EF2241.
11 1310 12 14 15
16
Figure 4. Inputs and outputs on back panel of the EF2241.
18
20
17
19
INSTALLATION
VORTEX EF2241 Reference Manual 8 Technical Support: 800.932.2774
I
NSTALLATION
This equipment is intended to only be installed by qualified service personnel. The
equipment shall be connected to a socket-outlet that provides a protective earthing
connection.
North American
Requirement
CAUTION-To reduce the risk of fire, use only No. 26 AWG or larger telecommunica-
tion line cord.
M
OUNTING
THE
EF2241
The EF2241 can be mounted in a rack enclosure using four large screws (10-32x1/2”)
included with the unit. One EF2241 fits in a single rack space.
Recommendation
For Easy Access
While not required, leave a single rack space in between the EF2241 and other units
in your rack. This gives you easier access to the back panel.
Instructions for
Securing Power
Supply to Back of
EF2241
Locate the cable clamp on the back panel of the EF2241 above the power con-
nector.
Remove the screw and thread the power cord through the cable clamp.
Attach the cable clamp to the back panel of the EF2241 and tighten the screw.
Align the clamp so that the power cable does not interfere with the connectors on
the EF2241 back panel.
Plug in the power supply.
We recommend that you also Ty-wrap the power supply to the rack. The purpose
of securing the power supply to the back panel is so that if the power supply were
to drop, it would pull where the cord is attached with the cable clamp and not pull
the plug out of the EF2241.
C
ONNECTING
THE
EF2241
TO
O
THER
E
QUIPMENT
Grounding The EF2241 has 4 mic/line inputs plus 4 line level inputs and 8 line level outputs.
Each input/output is “Pin 1 compatible” — this means that the ground pin of each
input/output is tied to chassis ground. Chassis ground is connected to the input power
ground.
Caution! Do not use any other power supply other than the one pro-
vided with this unit.
INSTALLATION
© Polycom, Inc. 9 VORTEX EF2241 Reference Manual
Typical EF2241
Connections
The EF2241 will typically be connected to other equipment in a single room setup as
shown below in Figure 5 and Figure 6.
The following steps are typically used to set up the EF2241:
Connect a microphone to each of the 4 mic/line level inputs. The mic/line input
accepts mini-Phoenix connectors. See “Connector Pinouts” on page 51 for
pinouts of Phoenix connectors.
Figure 5. Block diagram of typical EF2241 connections: a single room using one EF2241.
Figure 6. Typical EF2241 connections.
Vortex
®
EF2241
In 1
In 2
In 3
In 4
Out 1
Out 2
Out 3
Out 4
Spk Out
Phone
EFBus Out
In A
In D
In C
In B
Out A
Out D
Out C
Out B
EFBus In
Polycom Video
CODEC
Line In Line Out
PSTN
Line
PSTN
Polycom Video Codec, 4-wire Connection
Vortex
®
EF2241
POLYCOM CODEC
TX RX
INSTALLATION
VORTEX EF2241 Reference Manual 10 Technical Support: 800.932.2774
Connect speaker output to loudspeaker.
If RS-232 remote control is desired, connect the RS-232 R
EMOTE CONTROL port
of the EF2241 to the remote control device, such as an RS-232 interface to a
touch panel or a COM port on a personal computer.
Connect the L
INE RJ11 jack to an analog telephone line.
Connect the P
HONE RJ11 jack to an analog telephone set (optional).
Connect the external power supply to the P
OWER SUPPLY INPUT jack of the
EF2241.
Set the country code on the EF2241. By default the phone interface will be dis-
abled until you select a country code for the telephony interface. This can either
be done with the front panel LCD menu, or the RS-232 interface. The country
code only needs to be selected the first time or when the country of the installa-
tion is changed.
D
EVICE
ID
S
ON
THE
EF B
US
When considering which Device IDs can be used for which Vortex device, decide
how many devices have the ability to transmit on the W, X, Y, and Z busses, and how
many have the ability to transmit on the P Bus. The EF2280, for example can only
transmit on the W, X, Y, and Z busses while the EF2241 can transmit on the W, X, Y,
and Z busses as well as the P bus. Up to 8 devices can transmit on the W, X, Y, and Z
busses. Similarly, up to 8 devices can transmit on the P bus. Note that the EF2241
counts as one of both types. All devices that can transmit on W, X, Y, and Z must
have unique device IDs. Vortex devices of the same type must have unique device
IDs. If the device IDs of linked Vortex devices are the same, the front panel LCD
screen will display “EFBus Error: Dev. ID Conflict”.
C
ONNECTING
M
ULTIPLE
V
ORTEX
D
EVICES
Up to 8 Vortex devices in combination can be linked together at one time (See Device
IDs on the EF Bus above). Each unit in the chain must have a unique Device ID. Use
the EF Bus to link multiple Vortex devices together.
The following steps should be followed to connect the EF Bus:
1. Set a unique Device ID for each Vortex device. The Device IDs range from 00 to
07.
2. Power off all units.
3. Connect the RS-232 remote control device to any Vortex device in the chain.
4. Connect the provided Cat-5 cable between the EF B
US OUT of the first device,
and the EF B
US IN of the second device.
5. Connect another Cat-5 cable between the EF B
US OUT of the second device and
the EF B
US IN of the third device, and so on.
6. Power on all units at the same time.
Note. The EF Bus must be connected so that the EF Bus In of one
box is connected to the EF Bus Out of another. Connecting
the EF Bus In to another EF Bus In (or Out to Out) will not
work.
INSTALLATION
© Polycom, Inc. 11 VORTEX EF2241 Reference Manual
Terminating the
EF2241
The EF2241 is self-terminating so if you are connecting multiple EF2241s, the EF
Bus does NOT need to be terminated. However, if you are linking the EF2241 to
EF2280s, terminate the EF Bus link.
F
ACTORY
D
EFAULT
S
ETTINGS
(P
RESET
0)
The following is a list of the factory default settings of the EF2241. Since the micro-
phones and other equipment in your application may have different nominal levels,
you can start with a F
ACTORY PRESET (Presets 0-15), change it to match your envi-
ronment and then save it within the EF2241 as a U
SER PRESET (Presets 16-47). Once
you’ve saved a U
SER PRESET, set the POWER ON PRESET to that USER PRESET (or
Figure 7. Only the EF2280 needs to be terminated when linked together with
EF2241s.
Vortex EF2280
EF Bus Terminator
...
Cat-5 cable
Cat-5 cable
Cat-5 cable
Vortex EF2280
Vortex EF2241
No Terminator Needed
INSTALLATION
VORTEX EF2241 Reference Manual 12 Technical Support: 800.932.2774
whichever preset you want to come up after power up). The unit will need to be con-
figured for your system.
PROGRAM PARAMETERS FACTORY DEFAULT PRESET VALUE
SYSTEM PARAMETERS
Preset 0
Device ID 0
AUTOMIX PARAMETERS
Chairman Mode Off
Decay Time 1000 ms
Hold Time 500 ms
Last Mic On Mode On (on Automixer 1)
Max NOM per Automixer 4
Off Attenuation -15 dB
INPUT CHANNELS
Acoustic Echo Cancellation On
Automatic Gain Control (AGC) On
AGC Rate 1 dB/s
AGC Max Gain 3 dB
AGC Min Gain -3 dB
Automixer 1
Echo Canceller Reference Ref1
Filtering Off
Gate Priority 1
Adaptive Threshold 10 dB
Gate Threshold Adaptive
Gating Auto
INSTALLATION
© Polycom, Inc. 13 VORTEX EF2241 Reference Manual
Presets and
Multiple Vortex
Devices
PRESET 0 is preconfigured for a system with multiple Vortex devices. In Preset 0,
microphones are bussed out to other units on the W Bus. Microphones are also input
into each device on the W Bus (I
NPUT WM0 in the Matrix).
If you have multiple devices in your system, save settings to a user preset (Presets 16-
47) on each device. Saving a preset will only save the preset on that particular unit.
Also, remember to set the P
OWER ON PRESET to the User Preset that you have saved
your settings to otherwise the device will revert back to Preset 0 (factory default) if
power is lost.
C
HECK
S
URROUNDING
E
QUIPMENT
Now that the physical connections to the EF2241 are set up, it may be necessary to
check the surrounding equipment to make sure levels are set correctly. The following
suggestions may be helpful in integrating the EF2241 into your system:
Pick a Standard
Signal Level
A standard nominal signal level should be used throughout the audio system. Any
equipment that does not operate at this standard level should be compensated for as
close to the piece of equipment as possible. A 0 dB nominal level is a good standard
signal level. For example, a consumer VCR will probably generate a -8 dBu level.
As soon as the VCR signal arrives at an input with some gain control, the input gain
should be adjusted so that you get a 0 dB level, i.e. adding 8 dB of gain.
Check Levels to
the Codec
Configure the matrix mixer output to the codec input. The output
gain of the matrix mixer should be set to match the nominal input level of the codec.
For example, if the codec accepts -10 dBV (-8 dBu) inputs, 8 dB of attenuation should
be applied at the matrix mixer output to the codec.
Input Gains Mic Mode + 15 dB = 48 dB for Inputs 1-4
0 dB for Inputs A-D
Manual Threshold 60 dB
Mute Off
Noise Cancellation On
Noise Cancellation Level 10 dB
Phantom Power On
OUTPUT CHANNELS
Mute Off
NOM Attenuation On for Outputs 1-4
On for Outputs A-D
Output Gain 0 dB
P
ROGRAM PARAMETERS FACTORY DEFAULT PRESET VALUE
INSTALLATION
VORTEX EF2241 Reference Manual 14 Technical Support: 800.932.2774
Configure the matrix mixer input from the codec output. The input
gain of the matrix mixer should be set to match the nominal output level of the codec.
For example, if the codec outputs a -10 dBV (-8 dBu) level, 8 dB of gain should be
applied on the matrix mixer input. This will bring the codec level up to 0 dBu inside
the matrix.
Verify Room Gain After adjusting the loudspeaker level, verify the room gain in your system using the
R
OOM GAIN meter on the DIAGNOSTICS page of Conference Composer. The Room
Gain measurement is only accurate when just the remote talkers are speaking. If local
talkers are speaking too, the room gain meters are not accurate. See Figure 8 below.
The meter shows the room gain, which is the relative level of the output level and the
input level. While the EF2241 will operate in positive room gain conditions, the
room gain should be around 0 dB or a negative value. If you have a positive room
gain, make adjustments in the following areas:
1. Decrease the Input Gain of the microphone.
2. Decrease the Output Gain of the microphone.
3. OR adjust the placement of the microphone relative to the loudspeaker.
Configure
Program Audio
Sources
Set the gains on the matrix mixer inputs from the program audio sources so that pro-
gram audio is played into the room at a level similar to that of speech from the remote
site. This should also ensure that the program audio levels are good when sent to the
remote site.
Figure 8. Room Gain Meter on the Diagnostics page of the Conference Composer
control software.
Room Gain Meter
Read Room Gain
from here
INTEGRATING THE EF2241 INTO YOUR SYSTEM
© Polycom, Inc. 15 VORTEX EF2241 Reference Manual
I
NTEGRATING
THE
EF2241
I
NTO
Y
OUR
S
YSTEM
Operating the
EF2241
The EF2241 can be operated in two ways: through the LCD menu on the front panel
or through RS-232. For control via RS-232, please refer to the EF2241 Programming
Guide, which includes programming tips as well as the EF2241 RS-232 commands.
For operation using the PC control software, Conference Composer, please refer to
the Conference Composer User Guide.
Use Conference Composer software to easily configure the EF2241 with a PC, or
refer to the Applications Guide for different configurations that are already pro-
grammed into factory presets.
I
NPUT
S
ETTINGS
Set Inputs 1-4 for
Mic or Line Level
Configure Inputs 1-4 for mic or line level using the LCD menu (See “Level” on
page 30) or Conference Composer Control Software (See the Conference Composer
User Guide).
Select Phantom
Power for Inputs
1-4
Turn phantom power On or Off for Inputs 1-4 using the LCD menu (See “Phantom
Power” on page 30) or Conference Composer Control Software (See the Conference
Composer User Guide). Phantom power should be turned On for condenser and elec-
tret microphones.
C
ALIBRATION
When using the factory default, Preset 0, the following calibration can be used.
Set Mic/Line
Input Channel
Gains
In Preset 0, Automatic Gain Control (AGC) is On and the microphone gains on Inputs
1-4 are set to 15 dB. The AGC will compensate for the microphone gain. If you are
using ceiling microphones, set the microphone gain to 28 dB.
Fine tune the Input Gain using the Automatic Gain Control (AGC)
meter on Conference Composer Software.
In the Conference Composer
Software, go to the D
IAGNOSTICS page. Watch the meter labelled AGC while someone
is talking into the particular channel that you are adjusting. Watch the number in the
box at the bottom of the AGC meter (See Figure 9 below). This is the amount of gain
that the AGC is applying. The goal is to have the AGC meter on average staying
around 0. If the level that you see in the box is negative, decrease the input gain by
the average number that you see in the box because the AGC is attenuating the chan-
nel’s input gain because the level is too high. If the number in the box is positive,
increase the input gain on that channel because the AGC is boosting the signal
because it is too low. For example, if the meter is showing an average gain of -15 dB,
INTEGRATING THE EF2241 INTO YOUR SYSTEM
VORTEX EF2241 Reference Manual 16 Technical Support: 800.932.2774
you should increase your input gain by 15 dB. If the meter shows an average gain of
+10 dB, you should decrease your input gain by 10 dB.
Set Levels on Line
Input Channels
Set the line input channel gains (Channels A-D) to match the nominal level of the
incoming equipment. The line inputs have a maximum nominal level of 0 dBu. If
your incoming line level inputs have a higher nominal level than 0 dBu you will want
to use a pad to remove the level.
If you are connecting from equipment that has RCA plugs, you will most likely need
8 dB of gain on the Input and -8 dB of gain on the Output.
Figure 9. AGC Meter on the Diagnostics page of the Conference Composer soft-
ware. The gain adjustment is the same gain control on the Mic/Line Inputs page in
Conference Composer.
I
F THE AGC METER SHOWS... ADJUST THE INPUT GAIN IN THIS WAY.
positive gain Increase gain by the level
shown in the box.
negative gain Decrease gain by the level
shown in the box.
an average level of 0 dB You’ve set the Input Gain
to a good level!
Table 1: How to set the Input Gain using the AGC meter on the Conference
Composer Diagnostics page.
AGC Level Meter
Read AGC level
Adjust Input Gain here
INTEGRATING THE EF2241 INTO YOUR SYSTEM
© Polycom, Inc. 17 VORTEX EF2241 Reference Manual
Customize
Setting for Your
Particular
Application
The following sections will describe customizing parameters on the EF2241 for your
particular application if you are not using Preset 0.
S
ET
UP
THE
P
HONE
I
NTERFACE
The echo canceller reference of the EF2241 is by default set up with the phone input
already assigned to it.
By default the phone interface will be disabled until you select a country code for the
telephony interface. This can either be done with the front panel LCD menu, or the
RS-232 interface. The country code only needs to be selected the first time or when
the country of the installation is changed.
Send audio from the phone to the outputs on the same device by unmuting the cross-
point of Input T on that output. Send audio from the phone to other linked devices by
using the P bus output in the EF Bus. The linked devices can take the phone signal
off the bus from the P Bus input.
B
UILD
Y
OUR
E
CHO
C
ANCELLER
R
EFERENCE
The acoustic echo canceller (AEC) reference should generally contain exactly the
same audio signals as what is coming out of your loudspeaker(s), since the signal out-
put from the loudspeaker is what is then picked up by the room’s microphones caus-
ing acoustic echo. Note that this statement is a general statement. Conditions for this
being true follow:
If your system
does NOT have
sound
reinforcement,
The AEC reference should contain exactly the same audio as the loudspeaker
output: all far end audio, audio from the phone add, program audio, etc.
If your system contains stereo inputs and outputs, the reference must contain a
mix of both stereo inputs. For example, if your VCR audio is in stereo, the refer-
ence should contain both the left and right signals each attenuated by 3 dB, as
well as any other audio that is going to your loudspeaker.
If you are using crosspoint gains in the loudspeaker mix, apply the same gains to
the signals in your reference.
If your system
has sound
reinforcement,
Do NOT mix your room microphones into the reference, but include all other
audio (program audio, remote audio, phone audio, etc.).
E
CHO
C
ANCELLER
R
EFERENCE
FOR
M
ULTIPLE
V
ORTEX
D
EVICES
In a system with multiple devices, we recommend that one device be designated as
the unit that provides the EF bus reference for the acoustic echo cancellers. This unit
takes one of its reference signals (either Ref 1 or Ref 2) and places it on the EF bus.
All other units that are linked together may use the EF bus reference as the reference
INTEGRATING THE EF2241 INTO YOUR SYSTEM
VORTEX EF2241 Reference Manual 18 Technical Support: 800.932.2774
for their echo canceller, or they can use their own internal references. The references
may include a mix of any input, with crosspoint gains, including W, X, Y, and Z bus-
ses. Set the EF Bus Reference in the System Menu of the LCD Menu (See “EF Bus
Reference” on page 28).
Setting up the
Bus Reference
If all far end audio and program audio sources are on the same
Vortex device,
1. Assign far end audio and program audio sources to Reference 1 on the originat-
ing device.
2. On the EF Bus page in Conference Composer for the originating device, set the
Exported Signals to R
EFERENCE 1. Only one device can put an echo canceller
reference on the EF Bus as the Bus Reference.
3. On all linked devices, set the echo canceller reference to B
US.
For example, a system uses 1 EF2241, 1 EF2280, and 1 Polycom VS4000 video
codec. The Reference 1 is set up on EF2280 with ID 0. The Matrix for this EF2280
in Conference Composer is shown in Figure 10 and the EF Bus page in Figure 11.
Conference Composer will not allow more than one device assign their echo canceller
reference as the Bus Reference. Notice that the phone audio and VS4000 inputs are
both assigned to Reference 1 on the originating EF2280. The Matrix for any linked
devices is shown in Figure 12.
Figure 10. Matrix page of origin EF2280 (ID 00) Figure 11. EF Bus page of origin EF2280 (ID 00)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

Polycom EF2241 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI