Lightolier IS:C3MR is a versatile lighting fixture designed for recessed mounting in ceilings. It features a torsion spring mechanism for easy installation and removal of the trim faceplate, allowing for quick relamping. The adjustable rotational brake screw enables precise positioning of the lamp to direct light towards specific areas or objects. The trim is compatible with reflector trims provided by Lightolier, ensuring safety and compliance with Underwriters Laboratories listing.

Lightolier IS:C3MR is a versatile lighting fixture designed for recessed mounting in ceilings. It features a torsion spring mechanism for easy installation and removal of the trim faceplate, allowing for quick relamping. The adjustable rotational brake screw enables precise positioning of the lamp to direct light towards specific areas or objects. The trim is compatible with reflector trims provided by Lightolier, ensuring safety and compliance with Underwriters Laboratories listing.

U.S. AND FOREIGN PATENTS PENDING
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING LUMINAIRE
This luminaire is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electric shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSTALLATION PROCEDURE FOR CALCULITE® EVOLUTION TRIMS
WARNING: USE ONLY REFLECTOR TRIMS PROVIDED BY LIGHTOLIER. USE OF OTHER MANUFACTURER’S
REFLECTOR TRIMS MAY VOID THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.
INSTRUCTION SHEET NO.
IS: C3MR
B0206
Page 1 of 2
A COMPANY
631 Airport Road, Fall River, MA 02720
1. MAKE SURE THAT POWER TO THE LUMINAIRE IS OFF.
2. Select proper LAMP for application.
3. Remove TRIM FACEPLATE from TRIM BODY by
compressing TORSION SPRING. Fig. 1
4. Insert LAMP between LAMP SPRINGS of LAMP HOLDER
ASSEMBLY until face of LAMP sits firmly on GLASS LAMP
GUARD. Fig. 2
CAUTION! RISK OF FIRE. GLASS LAMP GUARD MUST BE
INSTALLED. Lamp manufacturers require the glass
lampguard be in place before energizing lamp, and that
great care must be taken that lamp is fully cooled before re-
lamping. Avoid finger marks on the inside of the lamp, as it
may shorten lamp life or cause breakage.
5. Insert LAMP HOLDER ASSEMBLY into TRIM BODY until
LAMP SPRINGS snap into place. Fig. 3
6. Bring TRIM BODY to FRAME and attach SOCKET to bi-pin
prongs on LAMP ensuring LAMPHOLDER ASSEMBLY remains
in place. Fig. 3
Prior to installing your LIGHTOLIER TRIM, the horizontal rotation
can be preset within the luminaire. Note the BEAM CENTERING
NOTCH Fig.4 allows the installer to predetermine the direction
the lamp will point to illuminate a wall or object of interest (not
applicable to downlight trims). Once the notch is aligned with the
object of interest, simply tighten the ROTATIONAL BRAKE
SCREW until the spring is fully compressed Fig. 5.
7. Ensure the two SECURING CLIPS are in the disengaged
position.Fig.1 on pg. 2. Align the two THICK CEILING READY
BRACKETS with the SECURING CLIPS and insert TRIM BODY
up until the bottom of TRIM BODY is flush or slightly recessed
from bottom of ceiling plane. Properly engage SECURING
CLIPS by pushing them into THICK CEILING READY
BRACKETS. Fig’s 2 & 3 on pg. 2
Fig. 1
Trim Body
Trim Faceplate
Torsion Spring
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Lamp
Lamp Springs
Lamp Holder
Assembly
Socket
Beam
Centering
Notch
Rotational
Brake Screw
Thick Ceiling
Ready Brackets
Lamp Removal
Spring
U.S. AND FOREIGN PATENTS PENDING
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING LUMINAIRE
This luminaire is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electric shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSTRUCTION SHEET NO.
IS: C3MR
B0206
Page 2 of 2
A COMPANY
631 Air
p
ort Road, Fall River, MA 02720
INSTALLATION PROCEDURE FOR CALCULITE
®
EVOLUTION TRIMS
8. Install TRIM FACEPLATE by compressing TORSION SPRING
into corresponding detail of TRIM BODY then pushing TRIM
FACEPLATE up flush to ceiling. Fig’s 4 & 5
TRIM MAINTENANCE
RELAMPING
- Make sure that power to luminaire is OFF.
To relamp, simply swing TRIM FACEPLATE down allowing
TORSION SPRING to hold in place. Pull down on LAMP
REMOVAL SPRING. Disconnect LAMP from LAMP
SPRINGS and SOCKET. Install new LAMP following steps
4, 5, and 6 above.
CARE OF ALZAK REFLECTOR- Wipe with a soft, clean,
dry, lint-free cloth, or wipe with a soft clean cloth
dampened in mild detergent solution, then rinse and
dry with a lint-free soft cloth.
Fig. 1
Fig. 2
Securing Clips in
the disengaged
position
Fig. 3
Insert Trim Body
Engage Clip
Trim Body Flush or
slightly recessed
Fig. 4 Fig. 5
  • Page 1 1
  • Page 2 2

Lightolier IS:C3MR User manual

Type
User manual

Lightolier IS:C3MR is a versatile lighting fixture designed for recessed mounting in ceilings. It features a torsion spring mechanism for easy installation and removal of the trim faceplate, allowing for quick relamping. The adjustable rotational brake screw enables precise positioning of the lamp to direct light towards specific areas or objects. The trim is compatible with reflector trims provided by Lightolier, ensuring safety and compliance with Underwriters Laboratories listing.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI