Tools and Materials
Thank You For Choosing Kohler Company
We appreciate your commitment to Kohler quality. Please take a few
minutes to review this manual before you start installation. If you
encounter any installation or performance problems, please don’t
hesitate to contact us. Our phone numbers and website are listed on
the back cover. Thanks again for choosing Kohler Company.
Before You Begin
CAUTION: Risk of property damage. Do not use plumbers
putty on marble or plastic, as it may stain the surface.
NOTE: Follow the installation dimensions precisely as there is no
deep rough-in kit available for this product.
Shut off the main water supply.
Observe all local plumbing and building codes.
Give special consideration to the exact location desired for your
faucet. This product is designed to give you the opportunity to be
creative and flexible with the installation.
Site preparation and wall finishing may require additional tools
and materials.
Kohler Co. reserves the right to make revisions in the design of
faucets without notice, as specified in the Price Book.
Solder
Propane
Torch
Tube Cutter
Pencil
Tape
Measure
#10 x 1"
Woodscrews
Level
1015917-2-D 2 Kohler Co.
1. Prepare the Site
NOTE: The wall plate requires special framing and support
considerations. Pay special attention to minimum and maximum
faucet height recommendations noted in the roughing-in sheet.
Refer to the roughing-in dimensions for additional mounting
information.
A suggested framing example is shown. Each installation may
have different framing requirements than those shown.
Construct the framing for your installation.
2. Attach the Wall Plate
Loosely attach the wall plate to the stud framing with six #10 x 1
panhead wood screws (not provided).
Verify that the installation is correct and level and firmly secure
the wall plate to the studs.
16"
(40.6 cm)
2x4 Stud
Framing
Screws
Wall Plate
Six Round Holes
(Typical)
5-5/8"
(14.3 cm)
Finished
Wall
1-1/2" (3.8 cm) Min.
2" (5.1 cm) Max.
2" (5.1 cm) Min.
2-1/2" (6.4 cm) Max.
Kohler Co. 3 1015917-2-D
3. Install the Mixer
Attach the mixer to the wall plate with the screws and washers
provided.
Tighten the screws securely.
Install 1/2 hot and cold supply piping to the mixer valve.
Temporarily pull the plaster guards from the handle and spout
shanks. Do not discard them at this time.
Position a bucket in front of the spout shank, and turn on the
water supplies to the mixer valve.
Slowly open the mixer valve stems, and allow the hot and cold
water to flow from the spout shank for about a minute.
Close the valve, and carefully inspect all connections for leakage.
Repair if necessary.
Turn off the water supplies. Open the valve stem to relieve the
water pressure.
Reattach the plaster guards to the handle and spout shanks.
Washers
Screws
Wall Plate
Mixer
1/2" Hot
Supply
1/2" Cold
Supply
Plaster
Guards
Setscrew
Handle
Assembly
1015917-2-D 4 Kohler Co.
4. Finish the Wall
NOTE: To ensure proper fit and appearance, do not oversize the
spout and handle shank holes.
Complete the finished wall with two 1-7/8 (4.8 cm) diameter
holes for the spout and handle shanks. Space the hole centers 4
(10.2 cm) apart.
Remove and discard the plaster guards when the finished wall is
complete.
5. Adjust the Water Temperature
NOTE: Prior to adjustment, make sure the handle is in the
maximum hot position.
Remove the handle, cap and escutcheon. Turn the water to the
maximum temperature by pushing the valve stem down and
turning counterclockwise.
Mark the current position of the temperature stop tab (top edge)
on the mounting nut with a marker or pencil. Lift both the
indexer and disc just enough to clear the splines and allow
rotation.
NOTE: Each spline notch represents an average 9.5° F (5.3° C)
temperature change.
Plaster
Guards
Mounting
Nut
Stop Tab
Valve Stem
Disc
Indexer
Splines
Kohler Co. 5 1015917-2-D
Adjust the Water Temperature (cont.)
Turn the indexer, disc, valve stem clockwise until the desired
cooler water temperature is achieved. Reinstall the indexer and
disc to the valve, making sure the disc is snapped fully into the
indexer.
Turn off the water. Reinstall the cap escutcheon and handle.
1015917-2-D 6 Kohler Co.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Kohler K-307-K-NA Installation guide

Category
Faucets
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI