The EPS/CPS includes an inverter/charger/ power supply all-in-one unit.
It consists of an inverter charger and rechargeable batter y they are housed in a portable enclosure.
You can use it to power most of your electrical appliances at home when mains power is not available.
In addition, you can use it as a charger to re-charge other 12V sealed lead acid batter y.
Make sure the EPS is switched off before connecting to AC wall socket .
Use the AC power cord provided in the package.
Please remember to switch off the EPS before connecting on the electrical appliances to the outlet.
Plug the electrical appliance into the AC output socket (on the side panel) and switch the EPS on.
The appliance connected to the EPS will work.
When the EPS is connected to an AC wall socket, it is an AC source to power the electrical appliances connected.
At the same time, the battery is being recharged.
When he AC source is cut off, the battery powers the electrical appliances connected and the battery is discharged.
You are advised not to keep recharging the battery continuously when the battery is at full or 80% capacity.
Overcharging will make the battery damaged.
When full charged LED turn green, please remove the charger if long time not to use it.
User Manual
1. INPUT CABLE SOCKET
2. CHARGER ON/OFF SWITCH
3. FULLY CHARGED LED INDICATOR
4. CHARGER WORKING STATUS LED
5. INVERTER ON/OFF SWITCH
6. INVERTER WORKING STATUS LED
7. FAULT LED
8. OUTPUT SOCKET
9. NEGTIVE TERMINAL BLOCK FOR EXTERNAL BATTERY
10. POSITIVE TERMINAL BLOCK FOR EXTERNAL BATTERY
11. VENTILATION HOLE(1500W-3000W)
12. INPUT CABLE
13. USER MANUAL
14. FUSE
13
12
Note:
150W-6 00W
1500W- 3000 W
1. 1X65ah battery can be installed in 150-300W system.
1 x 100ah battery has been installed in 600-3000W system.
The batter y terminal block is used for extra batter y which will be parallel in the system
2. 150W-1000W with one AC output and 1500-3000W with dual output.
1
2
1
1. INTRODUCTION
4. MATERIAL INDICATION
3. MAIN CHARACTERISTICS
2. FEATURES
12V DC to 220- 240V AC Modified sine wave or pure sine wave output
Charger Function
Continuous Power up to from 150W-3000W
Overload protection
150W-1000W single AC output
1500W-3000W dual AC outlets for running multiple electrical appliances
Installed with maintenance free sealed lead acid batter y, extra battery can be added by terminal block
5. TROUBLE SHOOTING
Fuse burned
Contact Seller for repair or changed
PCB broken
Change battery or re-connect the
battery
Battery's defective or
poor connection
Unplug the fault load
Earth fault protection
Contact seller for repairing or change
Strong collision cause
the circuit loosen
Red and green
LED not lit
Red and green
LED lit
Change fuse or contact technical support
Use a larger battery or connect more
batteries in parallel to increase the
back up time
AC loads power
consumption is higher
than the rated power
Replace the battery
Battery is old or defective
Battery run time is less
than expected
Over temperature protection
Overload protection
Short circuit protection
Change the battery
Remove or reduce load, wait for EPS cooling
Remove or reduce load or use bigger powerEPS
Remove short circuit load
TROUBLE POSSIBLE CAUSE SUGGESTED REMEDY
Battery over discharge,
low battery protection.
No AC
output
Red LED lit, green
LED not lit or beep
sound alarm
Stop to use it or switch off the charger
AC input voltage under
EPS beep long time but
5.2. When public power on, the problem happened in bypass and charger mode.
TROUBLE
POSSIBLE CAUSE SUGGESTED REMEDY
Tighten connection or re-connect
the AC power
Poor AC wire connection
Change fuse or contact technical support
built in fuse burned
It will be auto stop the charge or
you switch off charger mode
Battery will be fully
charged soon
When the public power on,
inverter mode can't be
charger mode switch to
5.3. Other problem
TROUBLE
POSSIBLE CAUSE
SUGGESTED REMEDY
It will working when in
charge mode, after fully
charged it will auto stop
It is normal
When AC main power
failure, it should be working
in inverter mode, but it is
not work
Contact seller for repairing or
replace it
EPS series unit output
waveform. Light noise
sounds it is normal
You can choose our CPS series
products with output waveform
pure sine wave
Used with sensitive loads,
there is light noise
Used with TV, radio snow
free or buzzing sound
Choose CPS series pure sine wave inverter with charger
Reading voltmeters can't
get accurate data
Use a true RMS reading
voltmeters
EPS output shows
low voltage
Cooling fan not working
Charge for the battery
Battery over discharge
Power dissipation caused by
the too long or thin cable
Use more shorter /wider DC cables
mode or adjust AC voltage
170V
still on working
Using time too long,
Switch off 10 minutes for cool
high temperature
5.1. When public power failure and Inverter switch ON, the problem happened in the inverter mode.
3
4
6. INSTALLATION
7. CAUTION
Ambient environment temperature below 40 degrees Celsius.
Store in a dry place, do not drip or splash water on the power inverter.
Do not place the EPS near a heating vent or any equipment which generates heat
Avoid dropping metal items or other objects on the EPS during operation.
They might spark or short circuit the battery or other electrical parts and may cause an explosion.
Do not place the EPS near flammable materials or in any location which may have flammable fumes or gases,
such as the batter y compartment of car
Ventilation: allow at least two inch of free space around the EPS for air flow/ heat release.
Make sure that someone is available to give assistance when you are using the EPS
Do not disassemble the EPS cabinet. Only qualified person can attempt to ser vice this product.
This product has no consumer ser viceable parts. Keep out of reach of children.
Do not put any object into the AC input socket except the AC power cord provided.
Keep the battery terminals clean. Regularly check all connections are secure & tight.
A loose connection can create high electrical resistance & generate excessive heat which is harmful to the product
The EPS shall not be used in connection with life suppor t systems or other medical equipment or devices.
The battery inside is sealed lead-acid type. Do not attempt to recondition it
Do not smoke, use matches, lighters or open flame while near batteries.
Do not place the EPS under direct sunlight.
PUBLIC POWER
BATTERY
BATTERY
BATTERY
BATTERY
AC LOAD
EPS UNIT
Extra 12V battery
1pc 12V, 100Ah battery inside
5
6
Note. After proper connection inverter and charger switch (5) and (2) and the LED display state belows:
Inverter
OFF/ON Switch(5)
ON
Fault red LED(7) lit
Battery over discharge, low voltage or short circuit,
overload, short circuit protection function
SWITCH STATE
Inverter green LED(6) lit Battery in good condition, inverter is ready for use
LED INDICATION EXPLANATION
Charger
OFF/ON Switch(2)
Fully Charged red LED (3) lit
Charger green LED (4) lit
Battery has been fully charged.
Public power on, charger mode is working
Fault red LED (7) lit
Public power AC input is not in good condition
ON
8. DISPOSAL
Old electrical appliances are recyclable. Do not dispose them in the domestic waste! Separately
deliver these in a valuable material collection point. Dispose the packing material environmentally
friendly. Please give cardboard and paper to the waste paper, foils to a valuable material collection
point.
Modified Sine Wave.
Pure Sine Wave.
CPS-150B
150W
300W
CPS-300B
300W
600W
EPS-150B
150W
300W
EPS-300B
300W
600W
EPS-1000B
1000W
2000W
EPS-1500B
1500W
3000W
220±10% 50Hz
Model
Rated Power
Surge Power
AC output
Wave form
Output
EPS-2000B
2000W
4000W
PP-3000
3000W
6000W
EPS-600B
600W
1200W
12V(10-15V) (Refer Product's Specification)
170-250V(220V) or 70-150V (110V)
Automatic Voltage Regulated
12V
5A 5A 5A 5A 10A 10A 15A
Constant Current, Constant Voltage, Floating Charge(Auto.3 Stage)
<8ms(Switch less than 5 times
within 1 minute)
160-200W 330-400W
160-200W
330-400W
630-700W
1100-1200W 1600-1700W
>60 auto. shutdown
Earth Leakage, Polarity Reverse, Over Voltage, Low Voltage, Overload,
Overheat, Short Circuit protection
DC Input
AC Input
AVR Protection function
Charge Way
Transfer time
Overload
Over Temperature
Other
Max.
Current
Protection
Function
Note: Specifications is subject to change without notices.
15A 15A
Input
Charger
2100-2200W 3200-3300W
Can be chosen(12ms or 500ms)
through dial switch.
9. SPECIFICATION
10. USAGE GUIDE
7
8
Resistive Loads
Selection: Choose inverter’s rated power a little higher than the load rated power.
E.g. Incandescent Lamp, Electric Iron, Printer, Stereo Equipment, etc.
Capacitive Loads
Selection: Choose Inverter’s rated power 2 times higher than the load rated power
E.g. CFL Lamp, Desktop Computer, Laptop, Television, LED Lamp, etc.
Inductive Loads
Selection; Choose Inverter’s rated power 5 times higher than the load rated power
E.g. Hari dr yer, Hand Drill, Pump, Fridge, Washing Machine, Microwave Oven, Air
Conditioner, Fan, etc
CAUTION
We do not warrant unit for any and all defects or damages caused by:
1. Incorrect wiring or installation of inverter, or direct connection to AC distribution
wiring leading to inverter being burnt out.
2. Shipping or transportation damages.
3. Breakdown or damage caused by physical damage.
4. Breakdown or damage caused by force majeure.
5. Exposure to unsuitable environmental conditions (such as rain, lighting strikes or
high humidity).
Please contact your dealer first before sending the faulty item back for ser vice
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

ACDC Dynamics EPS-2000B User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI