EVERPURE ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
EVERPURE ROM IV REVERSE OSMOSIS (RO) SYSTEM
2 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
INTRODUCTION
The ROM IV Reverse Osmosis (RO) System is designed to provide up to two (2) years of membrane life. This system is NSF
Certified to reduce a variety of contaminants.
INSPECTION
Before mounting the ROM IV System, inspect the parts. Use the table and illustration provided to verify the parts and
quantities. If any parts are missing, contact Customer Service at 800.279.9404 or by email at tech-support@pentair.com.
Parts Part Number
1. Head Assembly Special Order
2. RO Membrane ROM-G75 EV929775
3. ROM-PRE Prefilter Cartridge EV929675*
4. ROM-PST Postfilter Cartridge EV929676*
5. Tank Valve EV311655
6. Drain Saddle Valve EV311754
7. Port Plug EV310876
8. Storage Tank EV314698
9. Faucet Adapter EV312938
10. 3/8" Plastic Tubing (White) EV312843
11. 3/8" Plastic Tubing (Blue) EV544600
12. 1/4" Plastic Tubing Assembly (Red) EV305061
13. Lead-Free Air Gap Drinking Water Faucet SH244820
14. Plug, 3/8" Quick-Connect EV314487
15. Water Supply Adapter 4004337
*Prefilter and Postfilter cartridges sold as a set, part number
EV929670
1
24
3
5
8
12
11 10 9
6* 13
14
7
REPLACEMENT PARTS
Contact your local Pentair Everpure Dealer for filter cartridges or system replacement parts.
15
EVERPURE ROM IV REVERSE OSMOSIS (RO) SYSTEM
3 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
Tools Required
Hand or Electric Drill Phillips Screwdriver
Adjustable Wrenches (2) Towel
File Safety Glasses
Pencil Tape Measure
Utility Knife or Tube Cutter
(for plastic tubing) Drill Bits:
1/4-inch and 3/8-inch
Optional Materials
(For sinks without extra hole for faucet)
Hand or Electric Drill Center Punch
Plumber Tape Respirator
Drill Bits: 1/4-inch and
3/8-inch 1-3/8 inch Bi-metal or
Carbide Tipped Hole Saw
NOTE: Not all tools listed will be necessary for installation.
Read installation procedures before starting to
determine required tools.
SELECTING A MOUNTING LOCATION
1. Give consideration to the weight of the unit when
operating, i.e. when filled with water. Operating weight of
the ROM IV RO System is:
System without Storage Tank - 10.2 lbs (4.6 kgs)
Storage Tank - 29.4 lbs (13.3 kgs)
2. The location should allow for:
Minimum clearance of 2-1⁄2 inches (6.3 cm) under the
cartridge(s) so they can be lowered for removal
and replacement.
Adequate space for “in” and “out” water line
connections.
Be near a drain for flushing.
DIMENSIONS
(39.4 cm)
15.50
(24.1 cm)
9.50
(22.5 cm)
8.85
(12.5 cm)
4.92
3.10
3.25
(40.6 cm)
16.00"
(26.6cm)
10.5"
Figure 1
4 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
OPERATING SPECIFICATIONS
WARNING: Before installing the system, make certain
your water supply complies with the following
operating specifications. Failure to do so may
reduce the effectiveness of the system and will
void the warranty. Consult your local water
treatment utility or a certified water testing lab
to determine the quality for your water.
Temperature: 32-120°F (0-49°C)
Pressure: 40-100 psi (2.7-6.89 bar), non-shock
Total Dissolved Solids: 1000 ppm maximum
Maximum Hardness: 143 ppm
Sulfide, Iron and
Manganese:
Less than 0.1 ppm
Chlorine in Water Supply: Free chlorine - 0.1 ppm maximum
Water Supply pH Limits: 4 to 11
Turbidity: 1.0 NTU maximum
For cold water use only.
GENERAL PRECAUTIONS
WARNING: Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before or after the system. Systems
certified for cyst reduction may be used on
disinfected waters that may contain
filterable cysts.
WARNING: The ROM IV RO System contains replaceable
components that are critical to the efficiency of
the system. Replacement of the reverse osmosis
component should be with one of identical
specifications, as defined by the manufacturer,
to assure the same efficiency and contaminant
reduction performance.
WARNING: The ROM IV RO System contains a replaceable
RO membrane cartridge, critical for the effective
reduction of total dissolved solids. Product water
should be tested periodically to verify that the
system is working properly.
WARNING: The ROM IV RO System shall only be used for
arsenic reduction on chlorinated water supplies
containing detectable residual free chlorine
at the system inlet. Water systems using an
in-line chlorinator should provide a one-minute
chlorine contact time before the unit.
WARNING: The ROM IV RO System will not protect against
disease-causing bacteria or remove
naturally-occurring harmless bacteria.
CAUTION: The ROM IV RO System must be protected against
freezing which can cause the filter housing to
crack, resulting in water leakage.
CAUTION: Turn off water supply to head without cartridge if
it must be left unattended for an extended period
of time.
CAUTION: Do not use electrical heating tape on this unit.
NOTE: Substances listed as reduced are not necessarily in
your water. System must be maintained according to
manufacturer's instructions, including replacement
of filter cartridges.
NOTE: Your water must be within required limits for
satisfactory operation. If not, the RO membrane
cartridge’s life may be shortened and your warranty
will be voided (see Operating Specifications).
NOTE: Install on cold water line only.
NOTE: Do not install where system will be exposed to direct
sunlight.
NOTE: Make certain that installation complies with all state
and local laws and regulations.
NOTE: The filter cartridges and RO membrane cartridge
included with the system have limited service lives.
Changes in taste, odor, and color of the filtered water
indicate that the cartridges and/or membrane should
be replaced.
NOTE: During extended periods of non-use (such as during
a vacation), remove the membrane cartridge and
the filter cartridges from the unit and place them
in a sealed plastic bag. Store the cartridges in the
refrigerator for future use. When restarting the unit,
replace all cartridges and flush per instructions.
NOTE: If the ROM IV RO System stands for more than two (2)
to three (3) days without being used, the storage tank
should be emptied.
NOTE: Use only plumbers tape without adhesive backing
to seal joints. Do not use pipe compound (“pipe
dope”), sticks, or similar compounds with this unit;
they contain petroleum derivatives which can cause
crazing and cracking of the plastic in the filter
housing.
NOTE: Use only soap and water to clean components.
NOTE: Do not use aerosol sprays (bug spray, cleaning
fluids, etc.) near the ROM IV RO System. They contain
organic solvents which can cause crazing and
cracking of the plastic in the filter housing.
NOTE: After prolonged periods of non-use, such as a
vacation, it is recommended that the system be
flushed thoroughly. Let water run for two (2) to three
(3) minutes before using.
NOTE: Do not use a torch near the unit.
5 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
INSTALLATION
Please read all instructions and precautions before
installing and using your ROM IV.
For standard, under-sink installation on 3/8" (9.52
mm) steel, brass, or copper cold water line.
When selecting a mounting location of the system
and tank, take into consideration the length of tubing
required for connections between existing plumbing
and system components. Some installation sites may
require more tubing than provided in the kit.
Numbered diagrams correspond with numbered steps.
INSTALLING THE WATER SUPPLY ADAPTER
The supply adapter fits 1/2"-14 NPS supply threads or 3/8"
x 3/8" compression. If local codes permit, it may be used
to connect the system to the cold water supply line. If local
codes do not permit the use of the supply adapter, alternate
connectors can be obtained from your local supplier.
DIRECTIONS:
A. Turn off cold water supply line. If cold water line does not
have a shut-off valve under the sink, you should install
one.
B. Turn on the cold water faucet and allow all water to drain
from line.
C. Disconnect riser cold water supply valve.
D. Ensure the sealing gasket is fully seated into the feed
adapter valve female thread.
E. Install feed adapter valve onto supply valve as desired.
The feed adapter valve may be installed at the bottom of
the supply hose or the top of the cold water line. Hand
tighten only.
F. Connect the riser to the feed adapter valve.
NOTE: Be careful not to cross-thread.
1
6 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
FAUCET QUICK START
1 Mounting Hole Dimensions 2 Attach Reject Water Tubing
1-3/8" to 1-1/2" Dia
2" Max
sink goes
here
3/8" Red
Tubing To
Drain
1/4" Red
Tubing
Elbow With
Flow Control
3 Attach Quick-Connector to Faucet 4 Attach Product Water Tubing
3/8"
Blue
Tubing
5 Position Faucet 6 Add "C" Washer and Tighten
Insert
Tighten
1
2
7 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
SYSTEM QUICK START
ROM IV RO System 1 Secure Manifold
10.2 lbs
(4.62 kgs)
2 Tubing Locations 3 Connect Tubing to ROM-G75 Cartridge
Blue 3/8" Tubing
To Tank
Blue 3/8" Tubing
To Faucet
White 3/8" Tubing
1-3/4" Length
Untreated Water
In - 3/8"
8 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
4 Install ROM-G75 Cartridge 5 Install Cartridges
ROM-G75
1
2
6 7 Assemble Tank
ROM-PRE
ROM-PST
1
2
1
2
3/16”
90°
1
2
9 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
8 Connect To Drain
9 Connect Tank Tubing
Blue 3/8"
Tubing
Red 1/4" Tubing
To Faucet
Red 3/8"
Tubing
Blue 3/8"
Tubing
5 to 7 PSI
(0.34 to 0.48 Bar) 35 lbs
(15.9 kgs)
White 3/8"
Tubing
10 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
PUT SYSTEM INTO OPERATION QUICK START
1 Flush ROM-PRE Cartridge
Open
ROM-PRE
Closed
Flush for 5
minutes
Remove
Plug
Closed
Insert
Tubing
Red tubing
to faucet not
shown
OFF
To
Drain
Close to connect tubing
Open for flush cycle
11 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
2 Flush ROM-G75 and ROM-PST Cartridges
Open
Insert
Plug
Open
Remove
Tubing
Red tubing
to faucet not
shown
OPEN
To
Drain
Close to remove tubing
Open for flush cycle
ROM-G75
ROM-PST
Flush for 12 hours
12 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
3 Final Flush
Open
Open
Red tubing
to faucet not
shown
To
Drain
Open
ROM-G75
ROM-PRE
ROM-PST
Close for 3 hours
Open for 5 minutes
Repeat 3 times
13 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
HOW REVERSE OSMOSIS (RO) WORKS
The ROM IV RO System uses a semi-permeable membrane to
reduce dissolved salts, improving the taste and odor of your
water. The RO membrane cartridge contains multiple layers
of micron-thin film wound around a hollow center core. Water
molecules can pass through the cartridge, while dissolved
salts are rejected.
Your water supply is prefiltered to reduce dirt and chlorine
that may foul the membrane. The RO membrane cartridge
separates this prefiltered water into PRODUCT WATER and
REJECT WATER. Water pressure forces water through the
membrane within the RO membrane cartridge, and into
the storage tank. This is the product water. Dissolved salts
cannot pass through the membrane and are sent to the
drain as reject water. When the faucet is opened, product
water (permeate) is drawn from the storage tank through a
post-polishing filter. The post-polishing filter takes out any
remaining taste or odor in the water and provides you and
your family with cleaner, great-tasting water.
The ROM IV RO System also features an auto shut-off valve
which shuts off the system once the pressure in the storage
tank reaches 2/3 of the incoming water pressure (your water
pressure). When you open the faucet to draw water from the
storage tank, the pressure inside the tank drops and the auto
shut-off valve opens. The system then begins to operate,
replenishing the water you took from the storage tank.
Depending on the system's efficiency, for each gallon of water
produced, up to 1 gal (3.79 L) is discharged as reject water.
The storage tank can hold up to 3.2 gals (12.1 L) of water at a
time.
NOTE: When used under operating conditions specified
in this manual, the RO membrane cartridge of the
ROM IV RO System should last 12 to 24 months. The
precise life span of the RO membrane cartridge
will depend on the quality of the water entering
the system and the frequency with which you use
it. Frequent use prevents the dissolved salts from
building up on the membrane as scale. The more
water the system is required to produce, the longer
the membrane will last.
INSTALLATION
NOTE: Please read all instructions, specifications, and
precautions before installing and using your
ROM IV RO System.
NOTE: The ROM IV RO System may be installed under a sink,
counter or water cooler.
NOTE: The ROM IV RO System is installed vertically.
NOTE: Numbered diagrams correspond with
numbered steps.
Selecting the Faucet Location
NOTE: The drinking water faucet should be positioned with
function, convenience, and appearance in mind. An
adequate flat area is required to allow faucet base to
rest securely. The faucet fits through a 1-3/8" hole.
Most sinks have pre-drilled 1-3/8" or 1-1⁄2" diameter
holes that may be used for faucet installation. If
these pre-drilled holes cannot be used or are in an
inconvenient location, it will be necessary to drill a
1-3/8" hole. This procedure may generate dust which
can cause severe irritation if inhaled or come in
contact with the eyes. The use of safety glasses and
respirator for this procedure is recommended.
WARNING: Do not attempt to drill through an
all-porcelain sink. If you have an all-porcelain
sink, mount the faucet in pre-drilled sprayer
hole or drill through countertop next to sink.
WARNING: When drilling through a countertop, make sure
the area below the drilled area is free of wiring
and piping. Make certain that you have ample
room to make the proper connections to the
bottom of the faucet.
WARNING: Do not drill through a countertop that is more
than 1-inch thick.
WARNING: Do not attempt to drill through a tiled, marble,
granite or similar countertop. Consult a plumber
or the countertop manufacturer for advice or
assistance.
1. Line bottom of sink with newspaper to help prevent
metal shavings, parts, or tools from falling down drain.
2. Place masking tape over the area to be drilled to help
prevent scratches if drill bit slips.
3. Mark hole with center punch. Use a 1/4" drill bit for a
pilot hole.
4. Using a 1-3/8" hole saw, drill a hole completely through
the sink. Smooth the rough edges with a file.
D
C
14”
114”
32
41
Figure 2
14 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
Mounting the Faucet
1. Loosen stem-nut on faucet, remove metal "C" disc
(if attached).
2. Attach large diameter 3/8" (red) drain tube to barb fitting
at the faucet base. This tube should be long enough to
reach the drain clamp.
3. Locate the 1/4" red brine tube that has a preassembled
quick-connect elbow on one end. Connect the open end
to the small barb on the faucet. Make certain that the
tube is not kinked or stressed once the head assembly is
mounted.
4. Slide chrome plate and black rubber washer onto faucet
by threading both drain tubes through the holes in the
plate and washer.
5. Slide white extension onto long threaded section of
faucet. Open end of extension should come in contact
with base of faucet.
6. Slide the washer then the lock washer up threaded
section and thread stem nut on. Do NOT tighten nut at
this time.
7. Apply three (3) to five (5) wraps of plumbers tape to
faucet stem. Screw quick-connector onto end of threads.
8. Wet end of blue 3/8" tube. Push into bottom of connector.
for 3/4". Tug gently to be sure connection is complete.
9. To remove the tube, push on the fittings' collar and pull
the tube out.
10. Holding the faucet, feed the three (3) tubes through the
hole in the sink. Position the faucet handle at a
desired location.
11. Center the faucet and slip "C" disc between the white
extension and the bottom of the counter or sink. Tighten
the stem nut with a wrench until it is tight.
NOTE: Do not overtighten the lock nut. Snug down and
tighten until faucet is secure.
12. Firmly insert goose-neck spout into faucet base.
Countertop
1
3
2
4
5
6
7
8
10
Figure 3
Mounting the System
CAUTION: The filter head assembly should be mounted on a
stud or firm surface. The mounting bracket will
support the weight of the cartridges and help
prevent strain on the water lines.
1. Select location where unit is to be mounted. The head
assembly is mounted in a vertical position.
2. When mounting the ROM IV RO System, two (2) screws
are required to mount the head. Measure up from the
floor of the cabinet 15.5" (39.4 cm). See Figure 4. This
will provide clearance to change the cartridges. The two
(2) screws will be 14" (35.6) apart and level. Screw the
two (2) screws into the wall. Leave a gap between the
screw head and the wall of 1/8". The backside of the
system head has two (2) slots that will fit over the screw
heads and slide down to lock.
12.5" from mounting hole
to bottom of cartridge
2" clearance below cartridges
Figure 4
15 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
Connecting the Faucet
CAUTION: Water supply to the inlet of the ROM IV RO System
should have a separate shut-off valve. If it does
not, a separate shut-off should be installed.
1. Locate the 3/8" blue tubing from the faucet. See Figure
5. The tubing must not have sharp bends or kinks that
would restrict water flow. Cut length as needed. Place a
mark 3/4" (1.9 cm) from the end of the tubing.
IMPORTANT: A length of this 3/8" blue tubing will be
used to connect the storage tank to the manifold. When
cutting this tube, plan for the new piece to be used for
the tank.
Moisten the end of the tubing with water and insert
into the water outlet quick-connect fitting on the head
assembly . Push in until the mark is flush with the
quick-connect fitting.
2. Gently pull back on the tubing to ensure it is connected
properly. If the tubing comes out of fitting, cut a small
section off of the tubing and reconnect.
NOTE: Tubing may be quickly and easily removed from the
fitting if necessary. First, turn off the water supply to
the filter. Open faucet, then press in the collet around
the fitting while pulling the tubing with your other hand.
Blue 3/8"
Red 1/4"
ROM-PST
ROM-G75
ROM-PRE
Untreated
Water In
Red 3/8"
Blue 3/8"
Carbon Filtered
Only Water Out -
Remove Plug
Figure 5
Water
Supply
Adapter
Cold Water Supply
To Cold Water Faucet
16 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
Connecting the Water Supply
1. Determine the length of 3/8" white plastic tubing needed
to connect the inlet on the left side of the filter with the
water supply. Be sure to allow enough tubing to prevent
kinking and cut the tubing squarely. Place a mark 3/4"
(1.9 cm) from the end of the tubing.
2. Wet tubing with water and insert tubing into water supply
fitting 3/4" (1.9 cm) until mark is flush with fitting.
Installing the Drain Clamp
NOTE: If you have a single-basin sink with a disposal unit,
call Technical support at 800.279.9404 for options.
NOTE: Before installing the drain clamp, check the drain
pipes under the sink for corrosion. Corroded pipes
should be replaced before continuing
with installation.
3. Attach the drain clamp to a vertical section of the drain
pipe, about 6" (15.2 cm) above the trap. Make sure
the opening on the drain clamp is facing towards the
drinking water faucet. See Figure 6.
6 inches
Figure 6
4. Using the fitting hole of the drain clamp as a guide, drill
a 1/4" (0.6 cm) hole through one side of the drain pipe.
See Figure 7.
5. Remove the drain clamp from the drain pipe and enlarge
the hole with a 3/8" (1.0 cm) drill bit. Use a file to remove
rough edges from the drilled hole.
Figure 7
6. Make sure the black rubber gasket is adhered to the
inside of the drain clamp and place the drain clamp
assembly over the drilled hole. Look through the hole
and position the clamp so that the center of the clamp
hole is slightly higher (about 1/16") than the center of the
drilled hole, see Figure 8. Tighten the clamp securely.
7. Screw the plastic compression nut onto the drain clamp
until finger-tight.
Figure 8
Connecting the Faucet to the Drain
NOTE: This is a gravity-fed drain line. Any loops, kinks or
sharp bends must be eliminated before proceeding.
Failure to create a straight line to the drain may
result in reject water leaking through the air gap in
the faucet onto the countertop and below the faucet.
1. Align the 3/8" red tubing from the faucet with the
compression nut on the drain clamp, see Figure 9.
Create as straight a path as possible with the tubing.
Cut the tubing squarely below the nut and remove the
internal and external burrs.
2. Loosen the compression nut two (2) complete turns.
Insert the tubing into the nut until it stops. Tighten with
fingers, then tighten one (1) to two (2) turns with
a wrench.
Figure 9
17 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
INSTALLING THE CARTRIDGES
The cartridges are identified by the color of the label and the
model number.
Cartridge #1: Everpure ROM-PRE Filter Cartridge
Cartridge #2: Everpure ROM-G75 RO Cartridge
Cartridge #3: Everpure ROM-PST Filter Cartridge
Install the cartridges in order. If the cartridges are installed
out of order, the system will not filter correctly.
Install the ROM-G75 Cartridge
The ROM-G75 Reverse Osmosis (RO) Cartridge is installed in
the vertical position. There are three (3) quick-connect ports
that are labeled.
Inlet -White
Permeate (product water ) - Blue
Drain - Red
This cartridge is installed before the two outside cartridges.
The manifold assembly should already be mounted securely.
2
7
5
1
9
12
11
4
450
6
Swing
Down
3
Figure 10
The numbers in Figure 10 refer to the steps below.
1. Locate the red drain tubing with the preassembled elbow
fitting. This tube has already been assembled to
the faucet.
CAUTION: DO NOT remove the quick-connect elbow fitting
from the red tubing. This assembly contains
a flow control that may become damaged if
removed. The efficiency of the ROM IV RO System
may be affected.
2. Mark the short piece of red drain tubing 5/8" (1.6 cm)
from the end.
3. Insert the tube into the red drain port at the bottom of
the cartridge, Figure 11. Push it in until the mark is flush
with the quick-connect fitting.
4. The product water tube (blue) is preassembled to the
manifold. Inspect the check valve to be certain the flow is
in the upward direction.
5. Mark the short piece of tubing 5/8" (1.6 cm) from
the end.
6. Insert the tube into the blue permeate port at the bottom
of the ROM-G75 Cartridge, Figure 11. Push it in until the
mark is flush with the quick-connect fitting.
7. Locate the tubing that will become installed into the
inlet port of the ROM-G75 Cartridge. The tubing should
be installed in the elbow fitting coming out of the auto
shut-off valve. The length of the tube that is visible must
be 1" (2.5 cm).
8. Measure 5/8" (1.6 cm ) from the end of the tube and
mark it.
9. Rotate the quick-connect elbow upward 450.
10. Position the ROM-G75 Cartridge so the inlet port is in
position in front of the tubing. The cartridge will be tipped
out at the bottom and will not yet be held by the clips.
11. Push the cartridge onto the tubing until the 5/8" (1.6 cm)
mark is flush with the quick-connect fitting.
12. Swing the cartridge down. The elbow fitting must move
with the cartridge. The cartridge will snap into the two
clips. The tubing and the elbow should point directly into
the inlet port.
13. If the tubing does not position directly into the inlet port,
the cartridge should be slid up or down as needed.
NOTE: The bottom of the ROM-G75 Cartridge will be
supported by the lower leg of the bracket.
Blue Permeate
Red Drain
ROM-G75
Cartridge
Figure 11
18 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
Install the ROM-PRE Cartridge
Locate the ROM-PRE Cartridge and inspect the o-rings. They
should be clean and lightly lubricated with silicone grease.
1. Line up the tabs with the slots in the opening on the left
side of the head assembly. See Figure 12.
2. Insert the cartridge to full depth.
3. Rotate the cartridge 900 to the right (clockwise) to lock it
in place.
Figure 12
Install the ROM-PST Cartridge
Locate the ROM-PST Cartridge and inspect the o-rings. They
should be clean and lightly lubricated with silicone grease.
1. Line up the tabs with the slots in the opening on the right
side of the head assembly. See Figure 12.
2. Insert the cartridge to full depth.
3. Rotate the cartridge 900 to the right (clockwise) to lock it
in place.
Connecting the Storage Tank to the System
CAUTION: When tank is full, it weighs approximately 30 lbs
(13.6 kgs). Provide ample support under the tank.
1. Thread the tank valve onto the tank opening by turning it
clockwise until snug.
2. Locate the piece of blue tubing (cut off earlier) and mark
it 3/4" (1.9 cm) from the end. Moisten one end of the blue
tubing with water and insert with a twisting motion into the
port of the tank valve until the 3/4" mark is flush with the
quick-connect fitting.
3. Mark the remaining end 3/4" (1.9 cm) from the end. Wet the
end and insert into the open connection on the last (right
side) head until the 3/4" mark is flush with the quick-
connect fitting.
NOTE: The pressurized storage tank has capacity of 3.2 gals
(12.1 L). The tank's air pressure is factory-set at 5 to
7 psi when tank is empty.
PUTTING THE SYSTEM INTO OPERATION
CAUTION: Make certain head assembly is firmly attached
to wall to prevent it from falling and possibly
becoming damaged.
NOTE: The ROM IV RO System does not produce a high
volume of water on-demand as an ordinary filter
does. Water is produced at a slow, drop-by-drop rate.
The system requires about three (3) hours to fill the
storage tank. As water is taken from the tank, the
system automatically starts the cycle of replacing the
water and then stops water production when the tank
is full.
There are several steps that must be followed to properly
place the ROM IV RO System into operation. Before the supply
water is turned ON, see Figure 13:
Remove quick-connect plug on the left end of the
manifold and connect the port with tubing to a drain.
Turn shut-off valve to the OFF position.
Turn tank valve to the OFF position.
The faucet lever should be closed.
Quick-Connect Plug
Incoming Water Shut-Off Valve
Tank Valve
Figure 13
1. To flush the ROM-PRE Cartridge to a drain, remove the
quick-connect plug on the left end of the manifold and
insert a temporary length of tubing into the connection.
NOTE: Tubing and ball valve are supplied.
Turn on the incoming water supply. Flush the ROM-PRE
Cartridge to a drain for five (5) minutes at full flow to
remove any carbon fines.
CAUTION: Failure to flush the ROM-PRE Cartridge will
damage the ROM-G75 RO Membrane Cartridge.
This condition will void the warranty.
2. After five (5) minutes, close the incoming water valve.
Remove the temporary tubing and re-insert the quick-
connect plug.
19 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
3. Make sure tank valve is in the open position.
4. Open the shut-off valve.
5. Slowly turn on incoming water supply.
6. Open the faucet to turn on flow. Let the faucet run/drip
for 12 hours, then close it.
7. Allow three (3) hours for the tank to fill. Continue to
periodically check the installation for leaks. After
the storage tank is filled, open the faucet to flush the
postfilter cartridge (on the right side of the filter housing
assembly). Allow four (4) to five (5) minutes for all of the
water to drain from the tank. Close faucet and allow tank
to fill.
8. Repeat Step 7 three (3) times.
CAUTION: Visually check the entire system for leaks. If a
leak is present, see Troubleshooting.
NOTE: Initially, the water may appear cloudy. This is a result
of air trapped in the postfilter cartridge. It is not
harmful and will disappear in a matter of minutes. It
may take up to a week after installing a new
postfilter cartridge for the trapped air to dissipate.
The system is ready for operation. You can now enjoy quality
water from the ROM IV RO System.
TESTING YOUR REVERSE OSMOSIS SYSTEM
Total Dissolved Solids (TDS) Test
NOTE: Under NSF/ANSI Standard 58, it is highly
recommended that the product water is tested at
least every six (6) months to verify that the system is
performing satisfactorily.
WHEN TO CHANGE THE CARTRIDGES
The life of the cartridge depends on the water volume used
and the substances in the water. Normally, cartridges should
be changed at intervals of 12 months. Replace the cartridge
sooner if the water pressure at the faucet begins to drop
noticeably or if you notice changes in the taste, color, or flow
of the filtered water.
CHANGING THE CARTRIDGES
Replacement Cartridges:
Everpure ROM-PRE Filter Cartridge - EV929675
Everpure ROM-PST Filter Cartridge - EV929676
Everpure ROM-G75 RO Cartridge - EV929775
The prefilter and postfilter cartridges need to be changed
when the water pressure at the faucet begins to drop
noticeably or if there are changes in taste, color or flow of
the filtered water. All cartridges should be changed at the
same time. The cartridges are color-coded to indicate which
location they are installed into.
NOTE: Only the replacement cartridges listed can be used
with this system. Failure to use the recommended
replacement cartridges will void your warranty.
1. Place a small pan or towel under the ROM IV RO System
to catch any water tha may drip. Turn OFF incoming
water.
2. Remove the two (2) outside cartridges by twisting each
cartridge a 1/4-turn to the left (counterclockwise). Then
pull down to release.
3. Remove the center ROM-G75 Cartridge by swinging the
cartridge up and out, pivoting at the top connection. Once
the cartridge is out of the clips, the quick-connection at
the top can be disconnected. Disconnect both tubes from
the quick-connect fittings at the bottom.
4. Connect the red and blue tubes at the bottom of the new
ROM-G75 Cartridge.
5. Position the new ROM-G75 Cartridge so the inlet port
is in position in front of the tubing at the top of the
cartridge. Push the cartridge onto the tubing until it
reaches full depth. Swing the cartridge down (the elbow
fitting must swing with it) into the clips. Adjust the
cartridge up or down so the tubing and the elbow point
directly into the cartridge.
NOTE: The bottom of the ROM-G75 Cartridge will be
supported by the lower leg of the bracket.
6. Position the ROM-PRE Cartridge under the left side
head. Line up the tabs on the cartridge with the slots in
the head.
7. Push the new cartridge into the head until it can go no
further.
8. Twist the cartridge a 1/4-turn to the right (clockwise)
until it locks in place. Pull gently down to ensure the
cartridge is locked in place.
9. Repeat Steps 6, 7 and 8 for the ROM-PST Cartridge.
CAUTION: The ROM-PRE Cartridge may contain carbon fines
that will be removed during the initial flushing.
Follow the proper flushing procedure to prevent
damage to the ROM-G75 RO Cartridge.
20 ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
INITIAL FLUSHING OF CARTRIDGES
The installation of new cartridges requires that a preliminary
flushing of the cartridges be performed. This initial flushing
is required to prevent damage to the RO cartridge.
Refer to page 18, Putting the System into Operation, for the
complete flushing procedure.
SANITIZING PROCEDURE  CONTAMINATED WATER
SUPPLY/BOIL ALERTS
When the water system has been contaminated or a boil
water advisory has been discontinued, the ROM IV RO System
must be sanitized. If a boil water advisory has just been
discontinued: Flush the water lines according to your water
supplier's instructions. Open the delivery faucet and flush the
system for about 10 minutes, then follow the filter cartridge
replacement instructions below.
1. Turn off the water supply and open the faucet to
relieve pressure.
2. Remove the filter cartridges and discard in trash. Wash
hands with soap and warm water.
NOTE: If a drip pan is used, clean with dish soap and
warm water.
NOTE: The following steps require placing bleach into
the ROM IV RO System. Pentair Everpure offers a
hollow cartridge, Everpure 2JT Flushing/Sanitizing
Cartridge (EV9608-10), that is designed for this
application. The following steps describe how to use
the Pentair Everpure 2JT Cartridge (EV9608-10).
Sanitization Procedure With The Pentair
Everpure 2JT Cartridge (EV9608-10)
3. Grasp the tip of the outlet tower center, top of the
cartridge and pull out gently. The entire central plug with
the long tube attached will come out, leaving a hole.
Figure 14
4. Add about a teaspoon of laundry bleach (5.25% sodium
hypochlorite solution) to the empty flushing cartridge
through the hole in the top.
5. Lubricate o-ring with a high quality silicone lubricant.
Replace the central plug assembly and insert the
flushing cartridge into the first (left side) installed head.
NOTE: Do not use petroleum jelly to lubricate the o-rings. It
will degrade the o-rings.
CAUTION: DO NOT install the ROM-G75 RO Membrane
Cartridge for the sanitization procedure. The
solution will severely damage the membrane.
Figure 15
6. Install a port plug into the last (right side) head.
7. When the RO cartridge is removed, the blue tube from
the bottom of the cartridge can be used for the sanitizing
procedure. Remove the quick-connect elbow on the blue
tube and remove the short tube at the top
quick-connect elbow.
8. Connect the bottom end of the blue tubing to the quick-
connect elbow that is normally connected to the inlet
port of the RO cartridge.
9. The tank valve and the manifold shut-off valve should be
open. The faucet should be OFF.
10. Slowly open the water supply valve. Open the faucet and
monitor the water flowing out of the ROM IV RO System.
When the smell of chlorine is present, close the faucet
valve. The storage tank will fill with chlorinated water.
11. Wait for a period of at least 30 minutes to allow adequate
disinfection time.
12. Turn off the incoming water valve.
13. Open the faucet valve. The storage tank will drain out.
14. When the storage tank is emptied, close the faucet valve
and remove the 2JT Cartridge.
15. Install a new ROM-PRE Cartridge in the first (left
side) head.
16. Open the faucet valve and slowly open the incoming
water valve. Allow water to run for five (5) minutes. This
will flush carbon fines out of the new cartridge.
17. Close the faucet allowing the tank to fill three (3) to five
(5) minutes.
18. Turn off the incoming water valve.
19. Open the faucet to allow the tank to empty.
20. When the water flow has stopped, close the faucet and
open the incoming water valve to refill the tank for three
(3) to five (5) minutes.
21. Repeat Steps 17, 18 and 19 four (4) times.
22. Turn off the incoming water valve and open the faucet to
remove pressure.
23. Install the new ROM-PST Cartridge in the last (right
side) head.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

Everpure ROM IV Owner's manual

Category
Sanitary ware
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI