Hussong Mfg. Co, Inc. 7 Rev. 1 - May 2023
NDK-41-DV - PFS Report No. 22-838 Starng Serial Number: 23 N41DV00001 23
1.1 Appliance Cercaon
Laboratory: PFS in Coage Grove, Wisconsin
Standards:
• ANSI Z21.88-2019/CSA 2.33-2019, Vented Gas Fireplace
Heaters
• CSA 2.17 2017, Gas-Fired Appliances for Use at High
Altudes
This installaon must conform with local codes, or in the
absence of local codes, with the Naonal Fuel Gas Code,
ANSI Z223.1/NFPA 54, or the Natural Gas and Propane In-
stallaon Code, CSA B149.1.
1.2 California Proposion 65 Warning
⚠ WARNING: This product can expose you to chemicals
including Carbon Monoxide, that is an externally vented by-
product of fuel combuson, which is [are] known to the
State of California to cause birth defects or other reproduc-
ve harm. For more informaon, visit
www.P65Warnings.ca.gov.
1.3 Requirements for the Commonwealth of
Massachuses
The following requirements reference various Massachu-
ses and naonal codes not contained in this manual.
For all sidewall horizontally vented gas fueled equipment
installed in every dwelling, building or structure used in
whole or in part for residenal purposes, including those
owned or operated by the Commonwealth and where the
side wall exhaust vent terminaon is less than (7) feet
above nished grade in the area of the venng, including
but not limited to decks and porches, the following require-
ments shall be sased:
1.3.1 Installaon of Carbon Monoxide Detectors
At me of installaon of side wall horizontally vented gas
fueled equipment, the installing plumber or gas-er shall
observe that a hard wired carbon monoxide detector with
an alarm and baery back-up is installed on the oor level
where the gas equipment is to be installed. In addion, the
installing plumber or gas-er shall observe that a baery
operated or hard wired carbon monoxide detector is in-
stalled on each addional level of the dwelling, building or
structure served by the side wall horizontal vented gas
fueled equipment. It shall be the responsibility of the prop-
erty owner to secure the services of qualied licensed pro-
fessionals for the installaon of hard wired carbon monox-
ide detectors.
In the event that the side wall horizontally vented gas
fueled equipment is installed in a crawl space or ac, the
hard wired carbon monoxide detector with alarm and
baery back-up may be installed on the next adjacent oor
level. In the event that the requirements of this subdivision
can not be met at the me of compleon of installaon, the
owner shall have a period of thirty (30) days to comply with
the above requirements; provided, however, that during
said thirty (30) day period, a baery operated carbon mon-
oxide detector with an alarm shall be installed.
1.3.2 Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accordance with
the above provisions shall comply with NFPA 720 and be ANSI/UL
2034 listed and IAS cered.
1.3.3 Signage
A metal or plasc idencaon plate shall be permanently
mounted to the exterior of the building at a minimum of eight (8)
feet above grade directly in line with the exhaust vent terminal
for the horizontally vented gas fueled heang appliance or
equipment. The sign shall read, in print no less the one-half inch
(½) in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB-
STRUCTIONS”.
1.3.4 Inspecon
The state or local gas inspector of the side wall horizontally vent-
ed gas fueled equipment shall not approve the installaon un-
less, upon inspecon, the inspector observes carbon monoxide
detectors and signage installed in accordance with the provisions
of 248 CMR 5.08 (2) (a) 1 through 4.
1.3.5 Exempons
The following equipment is exempt from 248 CMR 5.08 (2) (a) 1
through 4: The equipment listed in Chapter 10 entled
“Equipment Not Required To Be Vented” in the most current
edion of NFPA 54 as adopted by the Board; and Product Ap-
proved side wall horizontally vented gas fueled equipment in-
stalled in a room or structure separate from the dwelling, build-
ing or structure used in whole or in part for residenal purposes.
1.3.6 Manufacturer Requirements
1.3.6.1 Gas Equipment Venng System Provided
When the manufacturer of Product Approved side wall horizon-
tally vented gas equipment provides a venng system design or
venng system components with the equipment, the instruc-
ons provided by the manufacturer for installaon of the equip-
ment and the venng system shall include:
• Detailed instrucons for the installaon of the venng sys-
tem design or the venng system components; and
• A complete parts list for the venng system design or
venng system.
1.3.7 Gas Equipment Venng System NOT Provided
When the manufacturer of Product Approved side wall horizon-
tally vented gas equipment does not provide the parts for
venng the ue gases, but idenes “special venng systems”,
the following requirements shall be sased by the manufactur-
er:
• The referenced “special venng systems” instrucons shall
be included with the appliance or equipment installaon
instrucons and;
• The “special venng systems” shall be Product Approved by
the Board, and the instrucons for that system shall include
a parts list and detailed installaon instrucons.
A copy of all installaon instrucons for all Product Approved
side wall horizontally vented gas fueled equipment, all venng
instrucons, all parts lists for venng instrucons, and/or all
venng design instrucons shall remain with the appliance or
equipment at the compleon of the installaon.
1.0 Introducon