HySecurity StrongArmPark DC Traffic Light Wiring Instructions

Category
Security device components
Type
Wiring Instructions
StrongArmPark DC Trafc Light Relay Connections D0658 Page 1
www.hysecurity.com © 2015 7/10/15
Scan QR code for Smart Phone access
to HySecurity website information.
Tech Support: 800-321-9947
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
RADIO
CLOSE
OPEN
OPEN
PARTIAL
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
RAD
I
O
O
PT
I
O
NS
ED
G
E
+
24V
OP
EN
C
O
M
D
U
AL
G
A
T
E
C
O
M
B
A
U
S
E
R2
C
O
M
N
O
DC
COMMON
TERMINALS
USER RELAY 1
Electro-mechanical
24VDC
24VDC
12VDC
12VDC
Red LED
heart
beat
indicates
processor is
working.
Mul-colored LED
indicates power and gate
status.
N
C
N
O
AC Powered TrAffiC LighT ConneCTions
Electro-mechanical
User 1 Relay
Use Relay 1 Logic to connect trafc lights
to the StrongArmPark DC.
Set to 3, Relay 1 becomes active when an
open limit is triggered and deactivates
when the open limit is released or a close
command is received.
After connecting AC power and the trafc
light wires to the Smart DC Controller, take
the following steps to congure Relay 1
Logic in the Installer Menu.
Access the Installer Menu.
While a static Run Mode code is being
displayed, press the MENU button twice.
(Bypasses the operator status displays.)
When the Close Timer display appears:
1. Access the Installer Menu by simultaneously
pressing and holding the RESET and OPEN
buttons.
2. Release both buttons to access Menu / Program
Mode.
3. Press PREV until the R1, RELAY 1 LOGIC appears
in the display.
4. Press SELECT which causes R1 to blink.
5. Press NEXT until R1 3 OPEN LIMIT appears in
the display.
6. Press SELECT. R1 stops blinking indicating your
setting has been accepted.
7. To return to RUN / Operate mode, press MENU.
NOTE: Installer Menu options can also be
congured through the use of a laptop computer
and the S.T.A.R.T. software.
R1 3 OPEN LIMIT
RELAY 1 LOGIC
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
N.O. wire to Green / Amber Trafc Light
N.C. wire to Red Trafc Light
CAUTION
Draw on accessory terminals cannot exceed 1A. If higher
amp draw is required, use a separate power supply.
Set Relay 1 Logic
Wiring Connections
30VDC, 10A 277VAC, 10A
Smart DC Trafc Light Smart DC Trafc Light
N.C. Red Light N.C. Red Light
N.O. Green (amber) N.O. Green (amber)
COM COM (DC Ground) COM COM (AC Neutral)
StrongArmPark DC Trafc Light Relay Connections D0658 Page 2
www.hysecurity.com © 2015 7/10/15
TO RELAY 1 NO
TO RELAY 1 NC
SET RELAY 1 LOGIC FOR
OPTION 3
OPEN LIMIT OUTPUT
AC & DC CONNECTIONS
REQUIRE A SEPARATE
POWER SUPPLY 30VDC,
10A
VAC SPEC:277VAC, 10A
DRAW ON ACCESSORY TERMINALS
CANNOT EXCEED 1AMP.
IF HIGHER AMP DRAW IS REQUIRED,
USE A SEPARATE POWER SUPPLY
OUT TO
AC OR DC
POWER
SUPPLY
GREEN RED
Wiring Diagram for StrongArmPark DC
D0656 Rev A
Not to Scale
  • Page 1 1
  • Page 2 2

HySecurity StrongArmPark DC Traffic Light Wiring Instructions

Category
Security device components
Type
Wiring Instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI