Enter the menu and press the button OK for 5 seconds, you can enter the CHECK MENU,
where it is possible to check the operating status of all inputs.
Note: If the Stop, Photocell 1 and Photocell 2, Edge 1 and Enge 2 contacts are not bridged in
selearning, they will be deactivated and can be reactivated through this menu, without repeating
times selearning.
INPUTS CONTROL MENU
Language
MENU
SEA
SET
LIMIT SWITCH
CLOSING 1
LIMIT SWITCH
OPENING 1
EDGE
1
EDGE
2
PHOTO
1
PHOTO
2
END
LIMIT SWITCH
CLOSING 2
0.0 V
voltage level
on the
batteries
This item indicates the battery charge level
LIMIT SWITCH
OPENING 2
PARTIAL
OPENING
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Blocked
Blocked
Blocked
Blocked
Blocked
Blocked
Blocked
START
STOP
START
MENU
OK
OK
OK
OK
OK
OK
OK
MENU FUNCTION TABLE
To access the Menu for input check keep pressed OK for about 5 seconds.
Description
Description
Exit menu
Start
Test
Stop
Test
Partial
Opening
Test
Safety
edge1
test
Safety
edge2
test
Photocell 1
test
Photocell 2
test
M1 Opening
limit switch
test
M1 Closing
limit switch
test
M2 Opening
limit switch
test
M2 Closing
limit switch
test
The contact must be a N.C. Contact. When activating the related
command on the display SET lights up, the input works. If SET is
always on, make sure that the contact is a N.C. contact or that the
related limit switch is not occupied.
The contact must be a N.C. Contact. When activating the related
command on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
The contact must be a N.C. Contact. When activating the related
command on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
The contact must be a N.C. Contact. When activating the related
command on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
The contact must be a N.C. Contact. When activating the related
command on the display SET lights up, the input works. If SET is
always on, make sure that the contact is a N.C. Contact or that the
related limit switch is not occupied.
The contact must be a N.C. Contact. When activating the related
command on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
The contact must be a N.C. Contact. When activating the related
command on the display SET lights up, the input works. If SET is
always on, make sure that the contact is a N.C. contact or that the
related limit switch is not occupied.
The contact must be a N.C. Contact. When activating the related
command on the display SET lights up, the input works. If SET is
always on, make sure that the contact is a N.C. Contact or that the
related limit switch is not occupied.
The contact must be a N.O. Contact . When activating the related
command on the display SET lights up, the input works.
If SET is always on, check the wirings.
The contact must be a N.C. Contact. When activating the related
command on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
The contact must be a N.O. Contact. When activating the related
command on the display SET lights up, the input works.
If SET is always on, check the wirings.
ENGLISH