Traulsen Up-Right Hinge Adjust Operating instructions

Type
Operating instructions
UP RIGHT UNITS
VOL. 1 NO. 0030
7/25/2017
TRAULSEN TECHNICAL BULLETIN
PRODUCT SERVICE DEPARTMENT
FORT WORTH, TX 76106
HINGE ADJUSTMENT INSTRUCTIONS
Introduction:
This technical bulletin is intended to aid the field in hinge adjustment. This technical bulletin may not
cover all situations that may arise in the field and final diagnosis of field based equipment is the sole
responsibility of the technician contracted to perform any work required.
Reason for adjustment Instructions
Contact Traulsen Technical Service:
If further assistance is needed feel free to contact Traulsen Technical Service at 800-825-8220 between
the hours of 7:30am 11:30am CST & 12:30pm 4:30pm CST.
Gasket not seated up against the
cabinet face on the handle side of the
door.
Remove the stainless steel hinge cover
from the hinges on the door by using a
thin screwdriver to pry the covers away.
As seen in Figure 1.
Loosen the 3 screws on each hinge.
Adjust plate to desired fit and tighten the
screws and replace hinge covers.
Gasket is not seated up against the
hinge side of the door.
Figure 1
  • Page 1 1

Traulsen Up-Right Hinge Adjust Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI