Zebex Z-6910 Series User manual

  • Hello! I've reviewed the user manual for the ZEBEX Z-6910, Z-6910M and Z-6910MS Bi-Optical In-Counter Scanners. This document describes the features and installation of the scanner, including its ability to connect to host systems and auxiliary devices, use of EAS systems, and laser safety information. I'm ready to answer your questions about this device's capabilities, operation, or any other related query. Feel free to ask!
  • What type of laser does the scanner use?
    What is the maximum current output of the auxiliary port for handheld scanner?
    How do I connect the scanner to the host system?
    What are the possible connection interfaces of the device?
    How do I activate auxiliary port for handheld scanner?
SuperbBiOpticalInCounterScanner
1
1Z6910
SuperbBiOpticalInCounterScanner
i
RevisionHistory
Changestotheoriginalmanualarelistedbelow:
VersionDateDescriptionofVersion
1.0July.01,2015Initialrelease
1.1December16,2015Correcteddimensioninspec
1.2January30,2016Addedtopcoverinstallation
1.3March24,2016AddedMversionscanner
1.4July26,2019USBsettingsrevised
SuperbBiOpticalInCounterScannerii
ImportantNotice
Nowarrantyofanykindismadeinregardtothismaterial,including,butnotlimitedto,
impliedwarrantiesofmerchantabilityorfitnessforaparticularpurpose.Wearenot
liableforanyerrorscontainedhereinorincidentalorconsequentialdamagesin
connectionwithfurnishing,performanceoruseofthismaterial.
Nopartofthisdocumentmaybereproduced,transmitted,storedinaretrievalsystem,
transcribed,ortranslatedintoanylanguageorcomputerlanguageinanyformorbyany
meanselectronic,mechanical,magnetic,optical,chemical,manualorotherwise,without
expresswrittenconsentandauthorization.
Wehavetakenreasonablemeasurestoprovideinformationinthismanualthatis
completeandaccurate.However,thematerialinthisguideisforinformationonly;we
reservetherighttomakechangesinproductdesignwithoutreservationandwithout
priornotification.Forthelatestrevisionpleasecontactyourdistributor.
Alltrademarksmentionedherein,registeredorotherwise,arethepropertiesoftheir
variousrespectiveowners.
Copyright©2019.Allrightsreserved.
ThismanualisinA5format.Pleasecheckyourprintersettingbeforeprintingitout.
SuperbBiOpticalInCounterScanner
iii
LaserSafety
ThescannercomplieswithsafetystandardIEC60825foraClassIlaserproduct.Avoid
longtermstaringintodirectlaserlight.
RadiantEnergy:TheAdvancedDualLaserOmnidirectionalInCounterScannerusestwo
lowpowervisiblelaserdiodesoperatingat650nminanoptomechanicalscanner
resultinginlessthan3.9µWradiatedpowerasobservedthrougha7mmapertureand
averagedover10seconds.
Donotattempttoremovetheprotectivehousingofthescanner,asunscannedlaserlight
withapeakoutputupto0.8mWwouldbeaccessibleinside.
LaserLightViewing:Thescanwindowistheonlyaperturethroughwhichlaserlightmay
beobservedfromthisproduct.Afailureofthescannermotor,whilethelaserdiode
continuestoemitalaserbeam,maycauseemissionlevelstoexceedthoseforsafe
operation.Thescannerhassafeguardstopreventthisoccurrence.If,however,a
stationarylaserbeamisemitted,thefailingscannershouldbedisconnectedfromits
powersourceimmediately.
Adjustments:Donotattemptanyadjustmentsoralterationofthisproduct.Donot
removetheprotectivehousingofthescanner.Therearenouserserviceablepartsinside.
Caution:Useofcontrolsoradjustmentsorperformanceofproceduresotherthanthose
specifiedhereinmayresultinhazardouslaserlightexposure.
Optical:Theuseofopticalinstrumentswiththisproductwillincreasetheeyehazard.
Opticalinstrumentsincludebinoculars,magnifyingglasses,andmicroscopesbutdonot
includenormaleyeglasseswornbytheuser.
ForCECountries
ThisscannerisinconformitywithCEstandards.Pleasenotethatanapproved,CEmarked
powersupplyunitshouldbeusedinordertomaintainCEconformance.
SuperbBiOpticalInCounterScanneriv
TableofContents
ImportantNotice .....................................................................................................................ii
Introduction ............................................................................................................................ 1
KeyFeatures ................................................................................................................... 1
Unpacking....................................................................................................................... 2
Components................................................................................................................... 3
Connection.............................................................................................................................. 6
ConnectingPower .......................................................................................................... 6
VerifyingScannerOperation .......................................................................................... 6
ConnectingtotheHost .................................................................................................. 7
InterfaceCable .......................................................................................... 7
InterfaceCableReplacement ......................................................................................... 8
Installation ............................................................................................................................ 11
PreInstallationConsiderations .................................................................................... 11
InstallingtheScannertotheCounter........................................................................... 11
ShelfMounting........................................................................................ 12
AuxiliaryHandheldScannerConnection ...................................................................... 14
ConnectingEASSystem ................................................................................................ 16
InstallingSDCard ......................................................................................................... 19
InstallingTopCover ...................................................................................................... 20
SetUp.................................................................................................................................... 21
ConfiguringtheScanner............................................................................................... 21
PowerUpSelfTest ....................................................................................................... 21
ScanTest ....................................................................................................................... 21
ParameterSetting ........................................................................................................ 22
ControllingtheScannerfromPOSSystem ................................................................... 23
Operation .............................................................................................................................. 24
LEDIndications............................................................................................................. 24
SoundIndications......................................................................................................... 24
SleepMode .................................................................................................................. 25
HowtoScan .......................................................................................................................... 26
ScanVolume................................................................................................................. 26
ScanMode.................................................................................................................... 26
MaintainingtheScanner....................................................................................................... 27
TroubleShooting................................................................................................................... 28
Specification.......................................................................................................................... 29
PinAssignment ..................................................................................................................... 30
DCJACK ................................................................................................... 30
Host ......................................................................................................... 30
AUX ......................................................................................................... 30
TDR.......................................................................................................... 31
VFD.......................................................................................................... 31
EAS .......................................................................................................... 31
InterfaceCable ............................................................................................................. 32
SuperbBiOpticalInCounterScanner
1
USERSMANUAL
Introduction
Builtwithbrilliantaccuracyandwidescanningangles,Z6910biopticscannereliminates
trafficsinhighvolumeretailenvironments.Featuringanoutstandingonepassscanning
ability,cashierscanscanitemswithoutconstantlyreadjustingthescannerpositions.By
movingthecheckoutlineatamuchhigherspeed,Z6910canhelpyouachieveanew
elevatedlevelofproductivityandefficiency.
KeyFeatures
Firstclassbiopticaltechnology
Excellentfirstreadrate
VisualdiagnosticLED
Easyonsiteconfigurationandupgradeability
SuperbBiOpticalInCounterScanner2
USERSMANUAL
Unpacking
Theomnidirectionalscannerpackagecontains:
SuperbBiOpticalInCounterScanner
Interfacecable
(Typedependsoncustomerselection)
Powersupply&powercord
(Modeldependsonelectrical
requirementsofyourgeographic
location)
Ifanycontentsaredamagedormissing,pleasecontactyourdealer
immediately.
SuperbBiOpticalInCounterScanner
3
USERSMANUAL
Components
TopView
ScannerTopView

DescriptionFunction
1LEDindicatorIndicatingreadingstatus
2Controlpanel4buttonscontrollingscannerfunctions(seethe
FontViewbelow)
3Speakerexit*2 Beeptoneindication
4Topscanwindow Laserapertureforverticalscanning
5BottomScanwindowLaserapertureforhorizontalscanning
SuperbBiOpticalInCounterScanner4
USERSMANUAL
RearView
ScannerRearView
DescriptionFunction
6DCJackExternalACpowerinput
7HostPortInterfacecommunicationconnectiontothehost
8USBHostNotinuseatthistime
9AUXPortConnectinganauxiliaryperipheraldevice,usuallya
handheldscanner
10TDRConnectinganoptionalTopDownReader
11ScaleHostNotinuseatthistime
12VFDNotinuseatthistime
13EASPortElectronicarticlesurveillanceconnection
SuperbBiOpticalInCounterScanner
5
USERSMANUAL
FrontView
DescriptionFunction
14EcommercePresstoreadthebarcode(s)bymobilecommerce
reader
15SelfTest Presstostartselftest
16VolumePresstocontrolvolume
17ManualEASdeactivationPresstodeactivateEAS
SuperbBiOpticalInCounterScanner6
USERSMANUAL
Connection
ConnectingPower
Thepowersupplyprovides+12voltsDCvoltagetothescanner;thedetailedpower
requirementisasbelow:
VoltageAC100~240
Frequency 50~60HZ
Current(RMS)1000mA
Output+12V
Apowercordisrequiredtoconnecttheelectricaloutletandpowersupply.Selectthe
properIECpowercordforyourcountry.Toconnectanexternalpowertothescanner,
plugthepowersupplyintothepowerjackonthescannerandthenplugthepower
supplyintoanACoutlet.BlueLEDwouldlightwhenthescannerispoweredandreadyto
scan.
ThescannerturnsonwhentheACpowerissupplied,andturnsoffwhenthepoweris
removed.Thereisnoon/offswitchonthescanneritself.
UseonlyanAC/DCpowersupplyapprovedforthescanner.Useofotherpowersupplies
maycausedamagetotheproduct,andvoidthefactorywarranty.Youmustverifythat
thepowersourcewillsupply“clean”electricalpowertotheequipment;thatis,itmust
befreeofexcesselectricalnoise.
VerifyingScannerOperation
Beforeconnectingthescannertohostormountingtocounter,youmayfollowthe
procedurebelowtoverifyscanningoperation.
1. Insertthe10pinmodularplugoftheinterfacecableintothe“Host”connectoron
thescanneruntilafirmclickisheard.
2. Plugtheotherendofthecabletothehost.
3. Powerupthescanner.
4. Presentaknowngoodtestbarcodetothescanner.Thescannershouldissueashort
beepandtheLEDshouldflashredmomentarily.

SuperbBiOpticalInCounterScanner
7
USERSMANUAL
Ifthescannerdoesnotproduceanybeeps,orproducesthewrongbeeps,or
theLEDisnotlitup,removethepowerconnectionandrefertothesection
ofTroubleshooting.
ConnectingtotheHost
Theinterfacecablecomeswithdifferenthostendconnectors,dependingonthehost.
Followthestepsbelowtoconnectthedevicetothehost.
1. Turnoffthehostsystem.
2. Connectthescannerandthehostwiththeinterfacecable(Refertoyourhost
manualtolocatethecorrectportforthescanner).
3. PlugthepowercabletothejackonthedeviceandconnectthepowercordtoanAC
outlet.
4. Ifnecessary,setupthescannerinterfacewiththebarcodeintheprogrammingguide.
(RefertotheSetUpsection.)
5. Turnonthehostsystem.
InterfaceCable
Thescannercommunicateswiththehostthroughvarioustypesofinterfaces.The
standardtypesofinterfaceare:
Keyboardwedge
RS232
USB(supportingHIDUSB,virtualCOMUSB)
IBM468x/469x

SuperbBiOpticalInCounterScanner8
USERSMANUAL
InterfaceCableReplacement
Thestandardinterfacecableisattachedtothescannerwitha10pinmodularconnector.
Whenproperlyseated,theconnectorissecuredinthescannerbottombyaflexible
retentiontab.Youcaneasilyreplacethecommunicationcableandsetuptheinterface
viaprogramming.Replacementcablescanbeobtainedfromyourdistributor.
Followthesestepstoreplacetheinterfacecable:
1. Turnoffthehostsystemandpoweroffthescanner.
2. Disconnecttheoldinterfacecablefromthehost.
3. Pressdownthesmalltabontheconnectorwheretheoldcableisattachedtothe
scannerandpullouttheconnector.
4. Insertthe10pinmodularplugofanewinterfacecableintothe“Hostconnector
onthescanneruntilitclicks.
5. Plugthenewcableintothehost.
6. Reprogramthescannerinterfacewithbarcodesbeloworrefertothe
ProgrammingGuideformoresettingguidance.
Enter/ExitProgrammingMode
Scanthisbarcodetoenterthesetuportoexitafterthesetupisfinished.TheLEDwould
remainredwheninprogrammingmode.

SuperbBiOpticalInCounterScanner
9
USERSMANUAL
ReturntoPC/ATdefault
ThisbarcodeallowssettingaskeyboardwedgeinterfaceforIBMPCAT/PS/2and
compatibles.
Covertheunwantedbarcodetoensurethatthescannerreadthe
desiredbarcodeonly.
ReturntoRS232default
TheRS232CinterfacescannerisoftenusedwhenconnectingtotheserialportofaPCor
terminal.
SuperbBiOpticalInCounterScanner10
USERSMANUAL
ReturntoHIDUSBdefault
Readingof“ReturntoHIDUSBdefaultsetsthedeviceintoHIDUSBinterfacesupport.
ReturntoUSBVirtualCOMportdefault
Readingof“ReturntoUSBVirtualCOMportdefaultsetsthedeviceintoUSBVirtual
COMportinterfacesupport.
Covertheunwantedbarcodetoensurethatthescannerreadthe
desiredbarcodeonly.
ReturntoWandEmulationDefault
SuperbBiOpticalInCounterScanner
11
USERSMANUAL
Installation
PreInstallationConsiderations
Beforemountingthescanner,someconsiderationsareasbelow:
Determinethedirectionofpackageflowforyourapplication.Locatetheoptimum
scannerpositioninthecountersurface.Payattentiontotheproductflow,distance
tothecounteredgeandconveniencefortheoperator.
Placementofthescannershouldalloweasyaccesstoothercomponentsaswellas
optimizecommunicationbetweenthescanner,thePOSterminal,theadditional
handheldscannerandanyEASperipheralequipment.Donotrouteinterfaces
cablesnearanyelectricalmotorsorothersourceofelectromagneticinterference.
Toensuremountingstability,avoidplacingthescannerinsuchawayastosubject
ittoexcessvibration,bumping,spilledliquid,etc.
Thescannershouldbeinstalledinalocationawayfromdirectsunlightsincehigh
levelsofambientlightreducescannereffectiveness.
Thescannerhousingisdesignedtoprovideadequatespaceforconvectivecooling.
However,toprolongworkinghours,thescannershouldbeplacedatwherethereis
adequateconvectiveairflowandnomajorheatproducingequipmentnearby.The
airtemperatureinsidethecheckstandmustnotexceed40°C(104°F).
InstallingtheScannertotheCounter
Thescanneristobemountedinthecounterbyshelfmounting.Youcanuseashelfto
supporttheunit.
Toprotectthedevice,whenmountingthescanner,donotturnthe
scannerupsidedownorpressonthewindowglass.
SuperbBiOpticalInCounterScanner12
USERSMANUAL
ShelfMounting
Youcanbuildashelfunderthecountersurfacetosupporttheunit.Refertothe
followingfigureforthedimensionsoftheopening.
ShelfMounting(Standard)
SuperbBiOpticalInCounterScanner
13
USERSMANUAL
ShelfMounting(Mversion)
SuperbBiOpticalInCounterScanner14
USERSMANUAL
AuxiliaryHandheldScannerConnection
AuxiliaryPort
Thescannerprovidesanauxiliaryportfortheuseofanadditionalperipheraldeviceto
beconnectedtothehostsystemviathescanneritself.Itisusuallyusedtoconnecta
handheldscannerforitemstoolargetoplaceonthecheckstand.
Theauxiliaryportwillsupport5VDCdeviceswitha300mAmaximumcurrent.Ifthe
auxiliarydeviceexceedsthisspecification,anexternalpowersupplywillberequiredto
powertheauxiliarydevice.
Cablepinoutinformationfortheauxiliaryportisasfollowing:
PinFunction
1Reserved(forfactoryuse)
2N.C.
3+5Voutput,300mAmax.
4RTS
5Ground
6TX
7RX
8NC
9CTS
10Reserved(forfactoryuse)
HandheldDataFormatRequirements
Beforeinstallation,theconnectedhandheldscannermustbeconfiguredtotransmitdata
formatasbelow.
Baudrate9600
Databit8
ParityNone
Stopbit1
HandshakingRTS/CTS
MessageterminatorSTX/ETX
/