Zebex Z-6910 Series User manual

Category
Bar code readers
Type
User manual
SuperbBiOpticalInCounterScanner
1
Z6910MS
SuperbBiOpticalInCounterScanner
i
RevisionHistory
Changestotheoriginalmanualarelistedbelow:
VersionDateDescriptionofVersion
1.0October6,2016Initialrelease
1.1November29,2016Dimensionmodified
1.2December28,2016Addedscalejumpersection
1.3April07,2017Correctedtypoincomponents
1.4October18,2018VFDvoltagecorrected
1.5July26,2019USBsettingrevised
ImportantNotice
Nowarrantyofanykindismadeinregardtothismaterial,including,butnotlimitedto,
impliedwarrantiesofmerchantabilityorfitnessforaparticularpurpose.Wearenot
liableforanyerrorscontainedhereinorincidentalorconsequentialdamagesin
connectionwithfurnishing,performanceoruseofthismaterial.
Nopartofthisdocumentmaybereproduced,transmitted,storedinaretrievalsystem,
transcribed,ortranslatedintoanylanguageorcomputerlanguageinanyformorbyany
meanselectronic,mechanical,magnetic,optical,chemical,manualorotherwise,without
expresswrittenconsentandauthorization.
Wehavetakenreasonablemeasurestoprovideinformationinthismanualthatis
completeandaccurate.However,thematerialinthisguideisforinformationonly;we
reservetherighttomakechangesinproductdesignwithoutreservationandwithout
priornotification.Forthelatestrevisionpleasecontactyourdistributor.
Alltrademarksmentionedherein,registeredorotherwise,arethepropertiesoftheir
variousrespectiveowners.
‘LEGALNOTE’blocksindicateproceduresoractivitieswhichmaybe
regulatedunderlawbygovernmentagencies.Itisyourresponsibilityto
ensurecompliancewiththeregulationsthatgoverninstallationof
weighingdevices.
Copyright©2019.Allrightsreserved.
ThismanualisinA5format.Pleasecheckyourprintersettingbeforeprintingitout.
SuperbBiOpticalInCounterScannerii
SuperbBiOpticalInCounterScanner
iii
LaserSafety
ThescannercomplieswithsafetystandardIEC60825foraClassIlaserproduct.Avoid
longtermstaringintodirectlaserlight.
RadiantEnergy:TheAdvancedDualLaserOmnidirectionalInCounterScannerusestwo
lowpowervisiblelaserdiodesoperatingat650nminanoptomechanicalscanner
resultinginlessthan3.9µWradiatedpowerasobservedthrougha7mmapertureand
averagedover10seconds.
Donotattempttoremovetheprotectivehousingofthescanner,asunscannedlaserlight
withapeakoutputupto0.8mWwouldbeaccessibleinside.
LaserLightViewing:Thescanwindowistheonlyaperturethroughwhichlaserlightmay
beobservedfromthisproduct.Afailureofthescannermotor,whilethelaserdiode
continuestoemitalaserbeam,maycauseemissionlevelstoexceedthoseforsafe
operation.Thescannerhassafeguardstopreventthisoccurrence.If,however,a
stationarylaserbeamisemitted,thefailingscannershouldbedisconnectedfromits
powersourceimmediately.
Adjustments:Donotattemptanyadjustmentsoralterationofthisproduct.Donot
removetheprotectivehousingofthescanner.Therearenouserserviceablepartsinside.
Caution:Useofcontrolsoradjustmentsorperformanceofproceduresotherthanthose
specifiedhereinmayresultinhazardouslaserlightexposure.
Optical:Theuseofopticalinstrumentswiththisproductwillincreasetheeyehazard.
Opticalinstrumentsincludebinoculars,magnifyingglasses,andmicroscopesbutdonot
includenormaleyeglasseswornbytheuser.
ForCECountries
ThisscannerisinconformitywithCEstandards.Pleasenotethatanapproved,CEmarked
powersupplyunitshouldbeusedinordertomaintainCEconformance.
SuperbBiOpticalInCounterScanneriv
TableofContents
ImportantNotice .....................................................................................................................ii
Introduction ............................................................................................................................ 2
KeyFeatures ................................................................................................................... 2
Unpacking....................................................................................................................... 3
Components................................................................................................................... 4
Connection.............................................................................................................................. 7
ConnectingPower .......................................................................................................... 7
VerifyingScannerOperation .......................................................................................... 8
ConnectingtotheHost .................................................................................................. 8
InterfaceCable .......................................................................................... 8
InterfaceCableReplacement ......................................................................................... 9
Installation ............................................................................................................................ 12
PreInstallationConsiderations .................................................................................... 12
InstallingtheScannertotheCounter........................................................................... 12
ShelfMounting........................................................................................ 13
AuxiliaryHandheldScannerConnection ...................................................................... 14
ConnectingEASSystem ................................................................................................ 16
InstallingSDCard ......................................................................................................... 19
SetUp.................................................................................................................................... 20
ConfiguringtheScanner............................................................................................... 20
PowerUpSelfTest ....................................................................................................... 20
ScanTest ....................................................................................................................... 20
ParameterSetting ........................................................................................................ 21
ControllingtheScannerfromPOSSystem ................................................................... 22
ScannerOperation ................................................................................................................ 23
LEDIndications............................................................................................................. 23
SoundIndications......................................................................................................... 24
SleepMode .................................................................................................................. 24
ScaleOperation..................................................................................................................... 25
PreOperation............................................................................................................... 25
LEDBehavior ................................................................................................................ 25
WeightingItems ........................................................................................................... 25
CalibratingtheScale..................................................................................................... 27
ScaleJumper(CalibrationSwitch)........................................................... 30
ScaleJumperSeal(CalibrationSwitchSeal) ............................................ 30
ScaleJumperCover(CalibrationSwitchCover)....................................... 30
Calibration............................................................................................... 31
SupplementaryDevice ................................................................................................. 32
Zeroingdevice ......................................................................................... 32
SuperbBiOpticalInCounterScanner
v
Taredevice .............................................................................................. 32
Levelingdevice........................................................................................ 32
Blockingdevice........................................................................................ 33
HowtoScan .......................................................................................................................... 34
ScanVolume................................................................................................................. 34
ScanMode.................................................................................................................... 34
MaintainingtheScanner....................................................................................................... 35
TroubleShooting................................................................................................................... 36
Specification.......................................................................................................................... 37
PinAssignment ..................................................................................................................... 39
DCJACK ................................................................................................... 39
Host ......................................................................................................... 39
AUX ......................................................................................................... 39
TDR.......................................................................................................... 40
VFD.......................................................................................................... 40
EAS .......................................................................................................... 40
InterfaceCable ............................................................................................................. 41
SuperbBiOpticalInCounterScanner2
USERSMANUAL
Introduction
Builtwithbrilliantaccuracyandwidescanningangles,Z6910MSbiopticscanner
eliminatestrafficsinhighvolumeretailenvironments.Featuringanoutstandingonepass
scanningability,cashierscanscanitemswithoutconstantlyreadjustingthescanner
positions.Bymovingthecheckoutlineatamuchhigherspeed,Z6910canhelpyou
achieveanewelevatedlevelofproductivityandefficiency.
KeyFeatures
Firstclassbiopticaltechnology
Excellentfirstreadrate
VisualdiagnosticLED
Easyonsiteconfigurationandupgradeability
Scanner/scalecombination
SuperbBiOpticalInCounterScanner
3
USERSMANUAL
Unpacking
Theomnidirectionalscannerpackagecontains:
SuperbBiOpticalInCounterScanner
Interfacecable
(Typedependsoncustomerselection)
Powersupply&powercord
(Modeldependsonelectrical
requirementsofyourgeographic
location)
Ifanycontentsaredamagedormissing,pleasecontactyourdealer
immediately.
SuperbBiOpticalInCounterScanner4
USERSMANUAL
Components
TopView
ScannerTopView

DescriptionFunction
1LEDindicatorIndicatingreadingstatus
2Controlpanel6buttonscontrollingscannerfunctions(seethe
FontViewbelow)
3Speakerexit*2 Beeptoneindication
4Topscanwindow Laserapertureforverticalscanning
5BottomScanwindow/Scale Laserapertureforhorizontalscanning/scalefor
weightmeasuring
SuperbBiOpticalInCounterScanner
5
USERSMANUAL
RearView
ScannerRearView
DescriptionFunction
6DCJackExternalACpowerinput
7HostPortInterfacecommunicationconnectiontothehost
8USBHostNotinuseatthistime
9AUXPortConnectinganauxiliaryperipheraldevice,usuallya
handheldscanner
10TDRConnectinganoptionalTopDownReader
11ScaleHostConnectinganexternalscaledevice
12VFDConnectinganexternaldisplay
13EASPortElectronicarticlesurveillanceconnection
SuperbBiOpticalInCounterScanner6
USERSMANUAL
FrontView
DescriptionFunction
14EcommercePresstoreadthebarcode(s)bymobilecommerce
reader
15ZeroPresstozerothescale/quitthesetting
16SelfTest Presstostartselftest
17VolumePresstocontrolvolume
18TarePresstotarethescale
19ManualEASdeactivationPresstodeactivateEAS
SuperbBiOpticalInCounterScanner
7
USERSMANUAL
Connection
ConnectingPower
Thepowersupplyprovides+12voltsDCvoltagetothescanner;thedetailedpower
requirementisasbelow:
VoltageAC100~240
Frequency 50~60HZ
Current(RMS)1000mA
Output+12V
Apowercordisrequiredtoconnecttheelectricaloutletandpowersupply.Selectthe
properIECpowercordforyourcountry.Toconnectanexternalpowertothescanner,
plugthepowersupplyintothepowerjackonthescannerandthenplugthepower
supplyintoanACoutlet.GreenLEDwouldlightwhenthescannerispoweredandready
toscan.
ThescannerturnsonwhentheACpowerissupplied,andturnsoffwhenthepoweris
removed.Thereisnoon/offswitchonthescanneritself.
UseonlyanAC/DCpowersupplyapprovedforthescanner.Useofotherpowersupplies
maycausedamagetotheproduct,andvoidthefactorywarranty.Youmustverifythat
thepowersourcewillsupply“clean”electricalpowertotheequipment;thatis,itmust
befreeofexcesselectricalnoise.
SuperbBiOpticalInCounterScanner8
USERSMANUAL
VerifyingScannerOperation
Beforeconnectingthescannertohostormountingtocounter,youmayfollowthe
procedurebelowtoverifyscanningoperation.
1. Insertthe10pinmodularplugoftheinterfacecableintothe“Host”connectoron
thescanneruntilafirmclickisheard.
2. Plugtheotherendofthecabletothehost.
3. Powerupthescanner.
4. Presentaknowngoodtestbarcodetothescanner.Thescannershouldissueashort
beepandtheLEDshouldflashredmomentarily.

Ifthescannerdoesnotproduceanybeeps,orproducesthewrongbeeps,or
theLEDisnotlitup,removethepowerconnectionandrefertothesection
ofTroubleshooting.
ConnectingtotheHost
Theinterfacecablecomeswithdifferenthostendconnectors,dependingonthehost.
Followthestepsbelowtoconnectthedevicetothehost.
1. Turnoffthehostsystem.
2. Connectthescannerandthehostwiththeinterfacecable(Refertoyourhost
manualtolocatethecorrectportforthescanner).
3. PlugthepowercabletothejackonthedeviceandconnectthepowercordtoanAC
outlet.
4. Ifnecessary,setupthescannerinterfacewiththebarcodeintheprogrammingguide.
(RefertotheSetUpsection.)
5. Turnonthehostsystem.
InterfaceCable
Thescannercommunicateswiththehostthroughvarioustypesofinterfaces.The
standardtypesofinterfaceare:
Keyboardwedge
RS232
USB(supportingHIDUSB,virtualCOMUSB)
IBM468x/469x

SuperbBiOpticalInCounterScanner
9
USERSMANUAL
InterfaceCableReplacement
Thestandardinterfacecableisattachedtothescannerwitha10pinmodularconnector.
Whenproperlyseated,theconnectorissecuredinthescannerbottombyaflexible
retentiontab.Youcaneasilyreplacethecommunicationcableandsetuptheinterface
viaprogramming.Replacementcablescanbeobtainedfromyourdistributor.
Followthesestepstoreplacetheinterfacecable:
1. Turnoffthehostsystemandpoweroffthescanner.
2. Disconnecttheoldinterfacecablefromthehost.
3. Pressdownthesmalltabontheconnectorwheretheoldcableisattachedtothe
scannerandpullouttheconnector.
4. Insertthe10pinmodularplugofanewinterfacecableintothe“Hostconnector
onthescanneruntilitclicks.
5. Plugthenewcableintothehost.
6. Reprogramthescannerinterfacewithbarcodesbeloworrefertothe
ProgrammingGuideformoresettingguidance.
Enter/ExitProgrammingMode
Scanthisbarcodetoenterthesetuportoexitafterthesetupisfinished.TheLEDwould
remainredwheninprogrammingmode.

SuperbBiOpticalInCounterScanner10
USERSMANUAL
ReturntoPC/ATdefault
ThisbarcodeallowssettingaskeyboardwedgeinterfaceforIBMPCAT/PS/2and
compatibles.
Covertheunwantedbarcodetoensurethatthescannerreadthe
desiredbarcodeonly.
ReturntoRS232default
TheRS232CinterfacescannerisoftenusedwhenconnectingtotheserialportofaPCor
terminal.
SuperbBiOpticalInCounterScanner
11
USERSMANUAL
ReturntoHIDUSBdefault
Readingof“ReturntoHIDUSBdefaultsetsthedeviceintoHIDUSBinterfacesupport.
ReturntoUSBVirtualCOMportdefault
Readingof“ReturntoUSBVirtualCOMportdefaultsetsthedeviceintoUSBVirtual
COMportinterfacesupport.
Covertheunwantedbarcodetoensurethatthescannerreadthe
desiredbarcodeonly.
ReturntoWandEmulationDefault
SuperbBiOpticalInCounterScanner12
USERSMANUAL
Installation
PreInstallationConsiderations
Beforemountingthescanner,someconsiderationsareasbelow:
Determinethedirectionofpackageflowforyourapplication.Locatetheoptimum
scannerpositioninthecountersurface.Payattentiontotheproductflow,distance
tothecounteredgeandconveniencefortheoperator.
Placementofthescannershouldalloweasyaccesstoothercomponentsaswellas
optimizecommunicationbetweenthescanner,thePOSterminal,theadditional
handheldscannerandanyEASperipheralequipment.Donotrouteinterfaces
cablesnearanyelectricalmotorsorothersourceofelectromagneticinterference.
Toensuremountingstability,avoidplacingthescannerinsuchawayastosubject
ittoexcessvibration,bumping,spilledliquid,etc.
Thescannershouldbeinstalledinalocationawayfromdirectsunlightsincehigh
levelsofambientlightreducescannereffectiveness.
Thescannerhousingisdesignedtoprovideadequatespaceforconvectivecooling.
However,toprolongworkinghours,thescannershouldbeplacedatwherethereis
adequateconvectiveairflowandnomajorheatproducingequipmentnearby.The
airtemperatureinsidethecheckstandmustnotexceed40°C(104°F).
InstallingtheScannertotheCounter
Thescanneristobemountedinthecounterbyshelfmounting.Youcanuseashelfto
supporttheunit.
Toprotectthedevice,whenmountingthescanner,donotturnthe
scannerupsidedownorpressonthewindowglass.
SuperbBiOpticalInCounterScanner
13
USERSMANUAL
ShelfMounting
Youcanbuildashelfunderthecountersurfacetosupporttheunit.Refertothe
followingfigureforthedimensionsoftheopening.
ShelfMounting
SuperbBiOpticalInCounterScanner14
USERSMANUAL
AuxiliaryHandheldScannerConnection
AuxiliaryPort
Thescannerprovidesanauxiliaryportfortheuseofanadditionalperipheraldeviceto
beconnectedtothehostsystemviathescanneritself.Itisusuallyusedtoconnecta
handheldscannerforitemstoolargetoplaceonthecheckstand.
Theauxiliaryportwillsupport5VDCdeviceswitha300mAmaximumcurrent.Ifthe
auxiliarydeviceexceedsthisspecification,anexternalpowersupplywillberequiredto
powertheauxiliarydevice.
Cablepinoutinformationfortheauxiliaryportisasfollowing:
PinFunction
1Reserved(forfactoryuse)
2N.C.
3+5Voutput,300mAmax.
4RTS
5Ground
6TX
7RX
8NC
9CTS
10Reserved(forfactoryuse)
HandheldDataFormatRequirements
Beforeinstallation,theconnectedhandheldscannermustbeconfiguredtotransmitdata
formatasbelow.
Baudrate9600
Databit8
ParityNone
Stopbit1
HandshakingRTS/CTS
MessageterminatorSTX/ETX
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47

Zebex Z-6910 Series User manual

Category
Bar code readers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI