Majestic Echelon II Direct Vent Gas Fireplace Architect Guide

  • Hello! I've reviewed the specification document for the Majestic ECHELON II 36 Gas Fireplace. This document provides detailed dimensions and requirements for installation, including venting and clearances. I'm ready to answer your questions about the fireplace's specifications and installation guidelines.
  • What is the minimum vertical venting required before attaching an elbow?
    What is the viewing area of the glass?
    What are the BTU ratings for the fireplace?
Specifications
Additional information can be found online at www.majesticproducts.com
MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH VIEWING AREA
Actual Framing Actual Framing Actual Framing Actual Framing
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
ECHELON II 36
Direct Vent Gas Fireplace
8-9/16" [218]
1" [25]
46-3/16" [1173]
17-1/8"
[435]
18-5/8"
[473]
o
CENTERED ON APPLIANCE
8" [203]
41-3/4"
[1061]
2-3/8"
[60]
8-9/16"
[218]
2-3/4"
[70]
23-3/4"
[603]
36-5/8"
[930]
39-1/4" [997]
49-1/2" [1257]
15-5/8"
[397]
42-1/2"
[1080]
24-1/2"
[622]
8-7/8"
[225]
7-1/4"
[184] GAS ACCESS ELECTRICAL ACCESS
4"
[102]
8-9/16"
[218]
63" [1600]
ECHEL36
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE
ECHEL36
30,000 BTU (NG)
27,000 BTU (LP)
ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING
35-1/2" x 12-1/2"
46-3/16" 48-1/4" 46-3/16" 48-1/4" 41-3/4" 42" 17-1/8" 18-1/4"
TOP
FRONTLEFT RIGHT
25"
[635]
24"
[610]
13-1/8"
[333]
16-3/4
"
[425]
40-5/16" [1024]
39" [991]
37-3/16" [945]
5/8" [16]
13-1/8"
[333]
23-3/8"
[594]
37-1/4" [946]
47" [1194]
4-15/16"
[126]
10-1/16"
[256]
28-5/16"
[719]
The PFF decorative front has an installed depth of 3/4" [19mm], measured from the
front of the non-combustible finishing material to the front of the decorative front.
CFT FRONT PFF FRONT
BEFORE FRAMING, PLEASE NOTE:
A minimum of 18" of vertical venting is required before attaching any elbow to the appliance.
Specifications
PRODUCT LISTING CODES
US ANSI Z21.88-2017
CAN CSA 2.33-2017
UL307B
Product information provided is
not complete and is subject to
change without notice. Product
installation must adhere strictly
to instructions accompanying
product to avoid risk of fire and
potential injury.
ECHEL36
MINIMUM FIREPLACE CLEARANCES
FRAMING DIMENSION
CLEARANCES TO COMBUSTIBLES
APPLIANCE LOCATION
88-1/8"
[2239]
62-1/2
"
[1588]
48-1/4" [1226]**
48-1/4" [1226]**
48-1/4"
[1226]**
48-1/4"
[1226]**
18-3/4"
[476]
24-1/2"
[622] 1"
[25]
1"
[25] See clearances
in install manual
Refer to install manual for hearth,
mantel and wall projection
information.
If a Passive Heat, Heat-Zone or
Heat Out will be installed, refer
install manual for instructions.
18 in. (457 mm) required when
Passive Heat Side Discharge Kit is
installed. Refer to the Passive Heat
kit instructions for more information.
MANTEL LEG/WALL PROJECTIONS
COMBUSTIBLE OR NON-COMBUSTIBLE
WALL PENETRATION
3' maximum
4-1/2"
minimum
FIREPLACE OPENING
See appliance dimension diagram
in install manual - Dimension B
Note: Clearance from
opening to
perpendicular wall
Top View
FIREPLACE OPENING
See appliance dimension diagram
in install manual - Dimension B
Note: Clearance from
opening to
perpendicular wall
Top View
7"
minimum UNLIMITED
Acceptable on both sides of opening
64"
[1626]
10" 12"
63"
[1600]
Do not pack with
insulation or
other material
* Shows center of vent framing
hole for top venting. Center of hole
is 1" [25] above center of horizontal
vent pipe.
Header depth
not to exceed
3-1/2" [89]
Adjust framing dimensions
for interior sheathing (such
as Sheetrock).
If appliance is installed o of oor,
maintain required clearances to
combustibles. Construct platform in
accordance with local building codes.
10" [254]
42"
[1067]
18-1/4"
[464]
48-1/4"
[1226]
31" [787]
0" [0]
0" [0]
55-1/2" [1410]
48" [1219]
1" [25]
1" [25]
Header depth
not to exceed
3-1/2" [89]
Adjust framing dimensions
for interior sheathing (such
as Sheetrock).
If appliance is installed o of oor,
maintain required clearances to
combustibles. Construct platform in
accordance with local building codes.
10" [254]
42"
[1067]
18-1/4"
[464]
48-1/4"
[1226]
31" [787]
0" [0]
0" [0]
55-1/2" [1410]
48" [1219]
1" [25]
1" [25]
GS/MAJ/ECHEL36_0420
Majestic — A Brand of Hearth & Home Technologies
7571 215th Street West | Lakeville, MN 55044
877-486-9123 | majesticproducts.com
MANTEL PROJECTIONS - NON-COMBUSTIBLE
MANTEL PROJECTIONS - COMBUSTIBLE
OVERLAP FIT INSIDE FIT
MEASUREMENTS FROM TOP EDGE
OF THE APPLIANCE OPENING
4
5
6
16
3
2
1
6
7
8
9
10
11
18
MAX.
Measurement from top edge of opening
to bottom of appliance = 24-1/2 IN.
MEASUREMENTS FROM TOP EDGE
OF THE APPLIANCE OPENING
4
5
6
16
9
10
18
MAX.
Measurement from top edge of opening
to bottom of appliance = 24-1/2 IN.
7
11
MEASUREMENT FROM
TOP EDGE OPENING
18 20
23
26
29
9
12
6
3
1
Measurement from top edge openin
g
to bottom of appliance = 24-1/2 IN.
MAX.
MEASUREMENTS FROM TOP EDGE
OF THE APPLIANCE OPENING
4
5
6
16
3
2
1
6
7
8
9
10
11
18
MAX.
Measurement from top edge of opening
to bottom of appliance = 24-1/2 IN.
WITHOUT
PASSIVE
HEAT
WITH
PASSIVE
HEAT
NOTE: All measurements in inches.
NOTE: All measurements in inches.
/