Technosystem SAU125 Operational Manual

Type
Operational Manual
SAU125
SAU125
250W SOLID STATE UHF
TV AMPLIFIER
P/N A.002526.01.04
OPERATIONAL MANUAL
Copia n°
________
Copy n°
Emessa il
Delivered
________
.
PLANT: VIA B. PONTECORVO 10
SETTEVILLE DI GUIDONIA 00012 (ROMA)
PHONE (+39) 07743521
FAX (+39) 0774356136
WEB : http: www.technosystem.it
SAU125
INDEX
Description Page
1. INSTALLATION AND SET-UP …………………………………1
1.1 Mounting Procedure …..…………………………………….1
1.2 Set-up Procedure …………..………………………………..2
1.2.1 Initial Tests………………………………..…………..2
2. OPERATION…..…………………………………………………..4
2.1 Front Panel…………………………………………………..4
2.1.1 SAU125 Display Menu…….…………………………6
2.2 Rear Panel…………………………………………………..9
SAU125
LIST OF FIGURE
Description Page
FIG. 1.1-1 - SAU125 UHF TV AMPLIFIER – REAR PANEL …………………………….1
FIG. 1.2.1-1 INITIAL TEST SET-UP…………………………………………………………3
FIG. 2.1-1 SAU125 – FRONT PANEL CONTROLS & DISPLAYS……………….……….4
FIG. 2.1.1-1 SAU125 250W UHF AMPLIFIER OPERATION DISPLAY…………………6
FIG. 2.2-1 SAU125 – REAR PANEL CONTROLS & DISPLAYS………………………....9
SAU125
1
1. INSTALLATION AND SET-UP
The SAU125 250W Solid State UHF TV Amplifier is composed of a 3U drawer
which can be mounted on a 19” standard rack.
1.1 Mounting Procedure
- Insert the drawer in its place on the rack and fix it with four rack screws.
- Connect the 220V (110V), 50/60Hz supply to the power plug located on the rear panel (Fig.
7.1, ref. 1).
- Connect the RF Input connector located on the rear panel ( Fig. 7.1 ref. 2) to the RF cable
coming from 5W RF Amplifier (exciter).
- Connect the RF OUT connector located on the rear panel (Fig. 7.1 ref. 3) to the successive
High Power RF Amplifier input, or the antenna system.
FIG. 1.1-1 - SAU125 UHF TV AMPLIFIER – REAR PANEL
3
2 1
SAU125
2
1.2 Set-up Procedure
In this paragraph are described the tests and alignments to be performed on the
SAU125. For this purpose, the following instruments are necessary:
- Spectrum analyzer, 0.1 to 1000 MHz with tracking generator TEK 2712 or
equivalent.
- 30dB –300W attenuator, BIRD 300A FFN 30 or equivalent.
Should any malfunction be detected, refer to chapter 6 for the specific
troubleshooting procedures.
1.2.1 Initial Tests
Once the procedure described in paragraph 7.1 has been carried out, perform the
following operations:
a) Perform set-up as shown in Fig. 3.2 and turn-on the SAU125 by moving
the ON/OFF switch of the front panel (Fig. 4.1 ref. 1) to ON position and
verify that the display goes ON (Fig. 4.1 ref. 6).
b) Preset the spectrum analyzer to the frequency band in accordance to the
selected TV channel.
c) Check that the SAU125 GAIN is 13dB. (Small signal)
d) Turn OFF the equipment, and remove the measurement set-up.
SAU125
3
FIG. 1.2.1-1 INITIAL TEST SET-UP
SAU125
4 SAU125
2. OPERATION
This chapter contains the description of the Controls and Indicators of the front
and rear panels of the SAU125 250W UHF TV Amplifier and their instruction for
use.
2.1 Front Panel
FIG. 2.1-1 SAU125 – FRONT PANEL CONTROLS & DISPLAYS
1 2 3 4 5
6 7 8 9
5 SAU125
CONTROLS &
DISPLAYS DESCRIPTION FIG. 2-1
SWITCH ON/OFF
Two position switch when in
ON enables the a.c. voltage to
P.S. input. Ref. 1
REGULAR (Green Led) Regular LED Ref. 2
ENABLE (Yellow Led) Enable Contact Ref. 3
FAILURE (Red Led) General Failure Ref. 4
DISPLAY Seven segment display for the
display of the measured
parameters and Error codes Ref. 6
UP Push button for the selection of
the parameter to be measured
and displayed Ref. 6
ENTER Push button for the selection of
the parameter to be measured
and displayed
Ref. 7
DOWN Push button for the selection of
the parameter to be measured
and displayed Ref. 8
6 SAU125
2.1.1 SAU125 DISPLAY MENU
AFTER 3 SEC.
LD MOS POWER AMPLIFIER
OPERATING DISPLAY SWITCH ON
FAILURE
ENABLE
REGULAR
FIRMWARE REVXXX
250W POWER UNIT
DOWN
ENTER
UP
DD MM YY TYPE
UP
FAILURE
REGULAR
ENABLE
DOWN
ENTER
UP
V1: 0.0V
08/11/07 14:57 250W
Temp. (^C) :25
08/11/07 14:57 250W
STATUS :[OFF]
ACTIVE ALARMS
UP ENABLE
OPERATING DISPLAY
FAILURE
OPERATING DISPLAY
REGULAR
UP
UP
OPERATING DISPLAY
ENABLE
FAILURE
REGULAR
REGULAR
FAILURE
ENABLE
ENTER
DOWN
UP
[OK]
ENTER
DOWN
UP
DOWN
ENTER
ENTER
ENABLE
UP REFPWR 0W AMP1
STATUS :[OFF]
PA1: 0.0A
08/11/07 14:57 250W
UP
OPERATING DISPLAY
UP ENABLE
FAILURE
REGULAR
OPERATING DISPLAY
FAILURE
UP
[OK]
ENTER
DOWN
UP
DOWN
08/11/07 14:57 250W
STATUS :[OFF]
ON AIR TIMER: 999999
08/11/07 14:57 250W
FWDPWR 0W AMP1
OPERATING DISPLAY
REGULAR
OPERATING DISPLAY
ENABLE
FAILURE
REGULAR [OK]
UP
ENTER
DOWN
UP
FIG. 2.1.1-1 SAU125 250W UHF AMPLIFIER
OPERATION DISPLAY
7 SAU125
The upper part of the display shows always the date,
the hour and the direct power. The status line shows the
condition of the amplifier “OFF” or “ON” and “OK” or
“NOT” for the indication of enable. Last line shows the
time of operation.
Second line for direct power of the indicated amplifier.
Third line for reflected power.
Second line for the control of the current of the RF
pallet.
Second line shows the voltage of the P.S.
Second line we have the indication of the temperature
of the heat synk.
08/11/07 14:57 250W
STATUS :[OFF]
ON AIR TIMER: 999999
OPERATING DISPLAY
ENABLE
FAILURE
REGULAR [OK] ENTER
DOWN
UP
ENTER
ENABLE REFPWR 0W AMP1
STATUS :[OFF]
FAILURE [OK]
DOWN
08/11/07 14:57 250W
FWDPWR 0W AMP1
OPERATING DISPLAY
REGULAR
UP
PA1: 0.0A
08/11/07 14:57 250W
ENABLE
FAILURE
REGULAR
OPERATING DISPLAY
ENTER
DOWN
UP
V1: 0.0V
08/11/07 14:57 250W
REGULAR
FAILURE
ENABLE
DOWN
ENTER
OPERATING DISPLAY
UP
Temp. (^C) :25
08/11/07 14:57 250W
STATUS :[OFF]
OPERATING DISPLAY
ENABLE
FAILURE
REGULAR
[OK]
ENTER
DOWN
UP
8 SAU125
3 Alarms in 1 minute will cause blocking of the
machine.
This display shows the different active alarms.
Reset active alarms, press UP and DOWN for 5 sec.
This display shows the data logger alarms
DD= Day MM= Mounth YY= Year
Reset alarms, press UP, DOWN and ENTER
For 5 sec.
ACTIVE ALARMS
ENABLE
FAILURE
OPERATING DISPLAY
REGULAR
ENTER
DOWN
UP
DD MM YY TYPE
FAILURE
REGULAR
ENABLE
DOWN
ENTER
UP
OPERATING DISPLAY
9 SAU125
2.2 REAR PANEL
FIG. 2.2-1 SAU125 – REAR PANEL CONTROLS & DISPLAYS
CONTROLS DESCRIPTION FIG. 4.1
RF IN N Type connector used for
connection of RF input signal
Ref. 1
RF OUT N Type connector used for
connection of RF output signal
Ref. 2
CONNECTOR
INTERFACE Parallel I/O Vac Line and
RS232/422 connectors
Ref. 3
POWER INLET, FUSE Connector for 110/220V
60/50Hz main supply line input
and main supply fuse
Ref. 4
1 2
3 4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Technosystem SAU125 Operational Manual

Type
Operational Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI